Development and pilot study of a bed-exit alarm based on a body-worn accelerometer

被引:0
|
作者
Wolf, K. -H. [1 ,2 ]
Hetzer, K. [3 ]
Schwabedissen, H. M. Zu [3 ]
Wiese, B. [4 ]
Marschollek, M. [5 ,6 ]
机构
[1] Tech Univ Carolo Wilhelmina Braunschweig, Peter L Reichertz Inst Med Informat, Inst Technol, D-38106 Braunschweig, Germany
[2] Hannover Med Sch, D-38106 Braunschweig, Germany
[3] Rheumatol Klinikum Braunschweig, Med Klin 4, Braunschweig, Germany
[4] Hannover Med Sch, Inst Biometry, Hannover, Germany
[5] Tech Univ Carolo Wilhelmina Braunschweig, Peter L Reichertz Inst Med Informat, Inst Technol, Hannover, Germany
[6] Hannover Med Sch, Hannover, Germany
来源
关键词
Geriatric; Nursing homes; Hospitals; Caregivers; Clinical trial; TRIAXIAL ACCELEROMETER; FALLS; PREVENTION; INPATIENTS; RESIDENTS; RISK;
D O I
10.1007/s00391-013-0560-2
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
Background. Falls are a major problem in hospitals and nursing homes. The consequences of falls can be severe, both for the individual and for the caring institution. Objective. The aim of the work presented here is to reduce the number of falls on a geriatric ward by monitoring patients more closely. To achieve this goal, a bed-exit alarm that reliably detects an attempt to get up has been constructed. Materials and methods. A requirements analysis revealed the nurses' and physicians' needs and preferences. Based on the gathered information, an incremental design process generated different prototypes. These were tested for the reliability of their ability to detect attempts to get up in both laboratory settings and with geriatric patients. Based on the result of these tests, a scalable technical solution has been developed and proven its reliability in a 1-year, randomized controlled pilot clinical trial on a geriatric ward. Results. The developed system is unobtrusive and easy to deploy. It has been tested in laboratory settings, usability tests and a 1-year randomized clinical trial with 98 patients. This paper focuses on the technical development of the system. We present different prototypes, the experiments and the pilot study used to evaluate their performance. Last but not least, we discuss the lessons learned so far. Conclusion. The developed bed-exit alarm is able to reliably detect patients' attempts to get up. The results of the clinical trial show that the system is able to reduce the number of falls on a geriatric ward. Next steps are the design of a specialized sensor node that is easier to use and can be applied on an even larger scale due to its reduced cost. A multi-center trial with a larger number of patients is required to confirm the results of this pilot study.
引用
收藏
页码:727 / 733
页数:7
相关论文
共 50 条
  • [41] Feasibility and Utility of Home-Based Gait Analysis Using Body-Worn Sensors
    Huang, Emily
    Sharp, Michael T.
    Osborn, Elizabeth
    MacLellan, Adam
    Mlynash, Michael
    Kemp, Stephanie
    Buckwalter, Marion S.
    Lansberg, Maarten G.
    STROKE, 2019, 50
  • [42] Officer Perceptions of Body-Worn Cameras Before and After Deployment: A Study of Three Departments
    Gaub, Janne E.
    Choate, David E.
    Todak, Natalie
    Katz, Charles M.
    White, Michael D.
    POLICE QUARTERLY, 2016, 19 (03) : 275 - 302
  • [43] Design and Development of a 3D Folded Slot Antenna for Body-Worn Wireless Devices
    Thai, Trang
    Sabatini, James
    Hasan, S. M. Shajedul
    2016 10TH INTERNATIONAL SYMPOSIUM ON MEDICAL INFORMATION AND COMMUNICATION TECHNOLOGY (ISMICT), 2016,
  • [44] Development of a standard fall data format for signals from body-worn sensors The FARSEEING consensus
    Klenk, J.
    Chiari, L.
    Helbostad, J. L.
    Zijlstra, W.
    Aminian, K.
    Todd, C.
    Bandinelli, S.
    Kerse, N.
    Schwickert, L.
    Mellone, S.
    Bagala, F.
    Delbaere, K.
    Hauer, K.
    Redmond, S. J.
    Robinovitch, S.
    Aziz, O.
    Schwenk, M.
    Zecevic, A.
    Zieschang, T.
    Becker, C.
    ZEITSCHRIFT FUR GERONTOLOGIE UND GERIATRIE, 2013, 46 (08): : 720 - 726
  • [45] Gait in Mild Alzheimer's Disease: Feasibility of Multi-Center Measurement in the Clinic and Home with Body-Worn Sensors: A Pilot Study
    Mc Ardle, Riona
    Morris, Rosie
    Hickey, Aodhan
    Del Din, Silvia
    Koychev, Ivan
    Gunn, Roger N.
    Lawson, Jennifer
    Zamboni, Giovanna
    Ridha, Basil
    Sahakian, Barbara J.
    Rowe, James B.
    Thomas, Alan
    Zetterberg, Henrik
    MacKay, Clare
    Lovestone, Simon
    Rochester, Lynn
    JOURNAL OF ALZHEIMERS DISEASE, 2018, 63 (01) : 331 - 341
  • [46] Basic Verification of Contact Force-Based Control with Full Body-Worn Assistive Robot
    Masaoka, Shinichi
    Funabora, Yuki
    Doki, Shinji
    2022 IEEE/SICE INTERNATIONAL SYMPOSIUM ON SYSTEM INTEGRATION (SII 2022), 2022, : 144 - 149
  • [47] IMPLEMENTATION AND EVALUATION OF A PHYSICAL ACTIVITY AND ENERGY EXPENDITURE ALGORITHM IN A SENSIUM™-BASED BODY-WORN DEVICE
    Hernandez-Silveira, M.
    Ang, S. -S.
    Mehta, T.
    Wang, B.
    Burdett, A.
    BIODEVICES: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ELECTRONICS AND DEVICES, 2012, : 219 - 223
  • [48] Body-Worn Camera Footage in the News: An Experimental Study of the Impact of Perspective and Framing on Viewer Perception
    Poirier, Brigitte
    Collin-Santerre, Justine
    Boivin, Remi
    CANADIAN JOURNAL OF CRIMINOLOGY AND CRIMINAL JUSTICE, 2022, 64 (01) : 82 - 98
  • [49] The effects of body-worn cameras on police-citizen encounters and police activity: evaluation of a pilot implementation in Philadelphia, PA
    Elizabeth R. Groff
    Cory Haberman
    Jennifer D. Wood
    Journal of Experimental Criminology, 2020, 16 : 463 - 480
  • [50] Classification of Finger Movements Based on Reflection Coefficient Variations of a Body-Worn Electrically Small Antenna
    Xu, Bin
    Li, Yang
    Kim, Youngwook
    IEEE ANTENNAS AND WIRELESS PROPAGATION LETTERS, 2017, 16 : 1812 - 1815