Development and pilot study of a bed-exit alarm based on a body-worn accelerometer

被引:0
|
作者
Wolf, K. -H. [1 ,2 ]
Hetzer, K. [3 ]
Schwabedissen, H. M. Zu [3 ]
Wiese, B. [4 ]
Marschollek, M. [5 ,6 ]
机构
[1] Tech Univ Carolo Wilhelmina Braunschweig, Peter L Reichertz Inst Med Informat, Inst Technol, D-38106 Braunschweig, Germany
[2] Hannover Med Sch, D-38106 Braunschweig, Germany
[3] Rheumatol Klinikum Braunschweig, Med Klin 4, Braunschweig, Germany
[4] Hannover Med Sch, Inst Biometry, Hannover, Germany
[5] Tech Univ Carolo Wilhelmina Braunschweig, Peter L Reichertz Inst Med Informat, Inst Technol, Hannover, Germany
[6] Hannover Med Sch, Hannover, Germany
来源
关键词
Geriatric; Nursing homes; Hospitals; Caregivers; Clinical trial; TRIAXIAL ACCELEROMETER; FALLS; PREVENTION; INPATIENTS; RESIDENTS; RISK;
D O I
10.1007/s00391-013-0560-2
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
Background. Falls are a major problem in hospitals and nursing homes. The consequences of falls can be severe, both for the individual and for the caring institution. Objective. The aim of the work presented here is to reduce the number of falls on a geriatric ward by monitoring patients more closely. To achieve this goal, a bed-exit alarm that reliably detects an attempt to get up has been constructed. Materials and methods. A requirements analysis revealed the nurses' and physicians' needs and preferences. Based on the gathered information, an incremental design process generated different prototypes. These were tested for the reliability of their ability to detect attempts to get up in both laboratory settings and with geriatric patients. Based on the result of these tests, a scalable technical solution has been developed and proven its reliability in a 1-year, randomized controlled pilot clinical trial on a geriatric ward. Results. The developed system is unobtrusive and easy to deploy. It has been tested in laboratory settings, usability tests and a 1-year randomized clinical trial with 98 patients. This paper focuses on the technical development of the system. We present different prototypes, the experiments and the pilot study used to evaluate their performance. Last but not least, we discuss the lessons learned so far. Conclusion. The developed bed-exit alarm is able to reliably detect patients' attempts to get up. The results of the clinical trial show that the system is able to reduce the number of falls on a geriatric ward. Next steps are the design of a specialized sensor node that is easier to use and can be applied on an even larger scale due to its reduced cost. A multi-center trial with a larger number of patients is required to confirm the results of this pilot study.
引用
收藏
页码:727 / 733
页数:7
相关论文
共 50 条
  • [31] Inertial Body-worn Sensor Data Segmentation by Boosting Threshold-based Detectors
    Shi, Yue
    Shi, Yuanchun
    Wang, Xia
    2012 16TH INTERNATIONAL SYMPOSIUM ON WEARABLE COMPUTERS (ISWC), 2012, : 114 - +
  • [32] A Highly Reliable Ultrasonic Sensor-Based Bed-Exit Detection System for the Elderly With Early Notification
    Lin, Chih-Lung
    Lee, Po-Ting
    Ho, Yuan-Hao
    Yang, Zong-Lin
    Lu, Yu-Hsien
    Chan, Chi-Yuan
    Sung, Pi-Shan
    IEEE SENSORS LETTERS, 2024, 8 (01) : 1 - 4
  • [33] Body-worn sensor based surrogates of minimum ground clearance in elderly fallers and controls
    Greene, Barry R.
    McGrath, Denise
    Foran, Timothy G.
    Doheny, Emer P.
    Caulfield, Brian
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 6499 - 6502
  • [34] DESIGN AND DEVELOPMENT OF FLEXIBLE FABRIC ANTENNA FOR BODY-WORN APPLICATIONS AND ITS PERFORMANCE STUDY UNDER FLAT AND BENT POSITIONS
    Subramaniam, Sankaralingam
    Gupta, Bhaskar
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2011, 53 (09) : 2004 - 2011
  • [35] CNN-Based Intention Recognition Using Body-Worn Inertial Measurement Units
    Bajraktari, Flake
    Rosskopf, Nikolas
    Pott, Peter P.
    2023 IEEE 36TH INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS, CBMS, 2023, : 760 - 765
  • [36] Body-Worn Versus Bell-and-Pad Alarm Device for the Management of Monosymptomatic Nocturnal Enuresis in Children A Randomized Controlled Trial
    Peck, Blake
    Peck, Bronwyn
    Harvey, Jack
    Green, Andrea
    Svedas, Kerrie
    Whitaker, Shirley
    Nethercote, Mark
    Shea, Rosemarie
    JOURNAL OF WOUND OSTOMY AND CONTINENCE NURSING, 2020, 47 (05) : 507 - 512
  • [37] Scripting police escalation of use of force through conjunctive analysis of body-worn camera footage: A systematic social observational pilot study
    Sytsma, Victoria A.
    Chillar, Vijay F.
    Piza, Eric L.
    JOURNAL OF CRIMINAL JUSTICE, 2021, 74
  • [38] Channel-Based Key Generation for Encrypted Body-Worn Wireless Sensor Networks
    Van Torre, Patrick
    SENSORS, 2016, 16 (09):
  • [39] Detecting activities from body-worn accelerometers via instance-based algorithms
    Bicocchi, Nicola
    Mamei, Marco
    Zambonelli, Franco
    PERVASIVE AND MOBILE COMPUTING, 2010, 6 (04) : 482 - 495
  • [40] The effects of body-worn cameras on police organisation and practice: a theory-based analysis
    Koen, Marthinus C.
    Willis, James J.
    Mastrofski, Stephen D.
    POLICING & SOCIETY, 2019, 29 (08): : 968 - 984