Development and pilot study of a bed-exit alarm based on a body-worn accelerometer

被引:0
|
作者
Wolf, K. -H. [1 ,2 ]
Hetzer, K. [3 ]
Schwabedissen, H. M. Zu [3 ]
Wiese, B. [4 ]
Marschollek, M. [5 ,6 ]
机构
[1] Tech Univ Carolo Wilhelmina Braunschweig, Peter L Reichertz Inst Med Informat, Inst Technol, D-38106 Braunschweig, Germany
[2] Hannover Med Sch, D-38106 Braunschweig, Germany
[3] Rheumatol Klinikum Braunschweig, Med Klin 4, Braunschweig, Germany
[4] Hannover Med Sch, Inst Biometry, Hannover, Germany
[5] Tech Univ Carolo Wilhelmina Braunschweig, Peter L Reichertz Inst Med Informat, Inst Technol, Hannover, Germany
[6] Hannover Med Sch, Hannover, Germany
来源
关键词
Geriatric; Nursing homes; Hospitals; Caregivers; Clinical trial; TRIAXIAL ACCELEROMETER; FALLS; PREVENTION; INPATIENTS; RESIDENTS; RISK;
D O I
10.1007/s00391-013-0560-2
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
Background. Falls are a major problem in hospitals and nursing homes. The consequences of falls can be severe, both for the individual and for the caring institution. Objective. The aim of the work presented here is to reduce the number of falls on a geriatric ward by monitoring patients more closely. To achieve this goal, a bed-exit alarm that reliably detects an attempt to get up has been constructed. Materials and methods. A requirements analysis revealed the nurses' and physicians' needs and preferences. Based on the gathered information, an incremental design process generated different prototypes. These were tested for the reliability of their ability to detect attempts to get up in both laboratory settings and with geriatric patients. Based on the result of these tests, a scalable technical solution has been developed and proven its reliability in a 1-year, randomized controlled pilot clinical trial on a geriatric ward. Results. The developed system is unobtrusive and easy to deploy. It has been tested in laboratory settings, usability tests and a 1-year randomized clinical trial with 98 patients. This paper focuses on the technical development of the system. We present different prototypes, the experiments and the pilot study used to evaluate their performance. Last but not least, we discuss the lessons learned so far. Conclusion. The developed bed-exit alarm is able to reliably detect patients' attempts to get up. The results of the clinical trial show that the system is able to reduce the number of falls on a geriatric ward. Next steps are the design of a specialized sensor node that is easier to use and can be applied on an even larger scale due to its reduced cost. A multi-center trial with a larger number of patients is required to confirm the results of this pilot study.
引用
收藏
页码:727 / 733
页数:7
相关论文
共 50 条
  • [1] Development and pilot study of a bed-exit alarm based on a body-worn accelerometer [Entwicklung und Pilotstudie eines Bettenausstiegsalarms mittels körperbezogener Beschleunigungssensoren]
    Wolf K.-H.
    Hetzer K.
    zu Schwabedissen H.M.
    Wiese B.
    Marschollek M.
    Zeitschrift für Gerontologie und Geriatrie, 2013, 46 (8) : 727 - 733
  • [2] Bed-exit alarm effectiveness
    Capezuti, Elizabeth
    Brush, Barbara L.
    Lane, Stephen
    Rabinowitz, Hannah U.
    Secic, Michelle
    ARCHIVES OF GERONTOLOGY AND GERIATRICS, 2009, 49 (01) : 27 - 31
  • [3] THE BODY-WORN ALARM IN THE TREATMENT OF CHILDHOOD ENURESIS
    BUTLER, RJ
    FORSYTHE, WI
    ROBERTSON, J
    BRITISH JOURNAL OF CLINICAL PRACTICE, 1990, 44 (06): : 237 - 241
  • [4] Design and Implementation of Bed-Exit Alarm System for Preventing Elderly Falling
    Wu, Ching-Ta
    Chen, Chien-Hsu
    ADVANCES IN HUMAN FACTORS AND ERGONOMICS IN HEALTHCARE AND MEDICAL DEVICES, 2020, 957 : 280 - 290
  • [5] Estimating Load Carriage from a Body-worn Accelerometer
    Williamson, James R.
    Dumas, Andrew
    Ciccarelli, Greg
    Hess, Austin R.
    Telfer, Brian A.
    Buller, Mark J.
    2015 IEEE 12TH INTERNATIONAL CONFERENCE ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS (BSN), 2015,
  • [6] Validation of a Body-Worn Accelerometer to Measure Activity Patterns in Octogenarians
    Taylor, Lynne M.
    Klenk, Jochen
    Maney, Alistair J.
    Kerse, Ngaire
    MacDonald, Bruce M.
    Maddison, Ralph
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2014, 95 (05): : 930 - 934
  • [7] Effect of Body-Worn Cameras on EMS Documentation Accuracy: A Pilot Study
    Ho, Jeffrey D.
    Dawes, Donald M.
    McKay, Evan M.
    Taliercio, Jeremy J.
    White, Scott D.
    Woodbury, Blair J.
    Sandefur, Mark A.
    Miner, James R.
    PREHOSPITAL EMERGENCY CARE, 2017, 21 (02) : 263 - 271
  • [8] Fuzzy inference-based fall detection using kinect and body-worn accelerometer
    Kwolek, Bogdan
    Kepski, Michal
    APPLIED SOFT COMPUTING, 2016, 40 : 305 - 318
  • [9] Embedded System for Fall Detection Using Body-worn Accelerometer and Depth Sensor
    Kepski, Michal
    Kwolek, Bogdan
    2015 IEEE 8TH INTERNATIONAL CONFERENCE ON INTELLIGENT DATA ACQUISITION AND ADVANCED COMPUTING SYSTEMS: TECHNOLOGY AND APPLICATIONS (IDAACS), VOLS 1-2, 2015, : 755 - 759
  • [10] Determining jumping performance from a single body-worn accelerometer using machine learning
    White, Mark G. E.
    Bezodis, Neil E.
    Neville, Jonathon
    Summers, Huw
    Rees, Paul
    PLOS ONE, 2022, 17 (02):