Anti-scatter grid evaluation for wide-cone CT

被引:7
|
作者
Melnyk, Roman [1 ]
Boudry, John [1 ]
Liu, Xin [2 ]
Adamak, Mark [1 ]
机构
[1] GE Healthcare, Waukesha, WI 53188 USA
[2] Missouri Univ Sci Technol, Rolla, MO 65409 USA
关键词
anti-scatter grid; scatter rejection; wide-cone CT;
D O I
10.1117/12.2043619
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Scatter is a significant source of image artifacts in wide-cone CT. Scatter management includes both scatter rejection and scatter correction. The common scatter rejection approach is to use an anti-scatter grid (ASG). Conventional CT scanners (with detector coverage not exceeding 40mm along the patient axis) typically employ one-dimensional (1D) ASGs. Such grids are quite effective for small cone angles. For larger cone angles, however, simply increasing the aspect ratio of a 1D ASG is not sufficient. In addition, a 1D ASG offers no scatter rejection along the patient axis. To ensure adequate image quality in wide-cone CT, a two-dimensional (2D) ASG is needed. In this work, we measured the amount of scatter and the degree of image artifacts typically attributable to scatter for four prototype 2D ASG designs, and we compared those to a 1D ASG. The scatter was measured in terms of the scatter-to-primary ratio (SPR). The cupping and ghosting artifacts were assessed through quantitative metrics. For the 2D ASGs, when compared to the 1D ASG, the SPR decreased by up to 66% and 75% for 35cm water and 48cm polyethylene, respectively, phantoms, at 80-160mm apertures (referenced to isocenter), as measured by the pinhole method. As measured by the two-aperture method, the SPR reduction was 59%-68% at isocenter for the 35cm water phantom at 160mm aperture. The cupping artifact was decreased by up to similar to 80%. The ghosting artifact was reduced as well. The results of the evaluation clearly demonstrate the advantage of using a 2D ASG for wide-cone CT.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Coupling the use of anti-scatter grid with analytical scatter estimation in cone beam CT
    Rinkel, J.
    Gerfault, L.
    Esteve, F.
    Dinten, J. -M.
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [2] Removing the anti-scatter grid in mammography
    Highnam, RP
    Brady, JM
    Shepstone, BJ
    DIGITAL MAMMOGRAPHY '96, 1996, 1119 : 459 - 462
  • [3] Experimental Evaluation of a New Anti-Scatter Grid for Digital Radiographic Systems
    Fetterly, K.
    Schueler, B.
    MEDICAL PHYSICS, 2008, 35 (06) : 2677 - +
  • [4] Monte Carlo simulation of bowtie filter scatter on a wide-cone low-dose CT system
    Liu, Xin
    Srivastava, Anjali
    Lee, Hyoung-Koo
    Hsieh, Jiang
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [5] Simulation of Scattered Radiation with Various Anti-Scatter Grid Designs in a Photon Counting CT
    Zhan, Xiaohui
    Zimmerman, Kevin
    Cai, Liang
    Lai, Xiaochun
    Kaul, Madhuri
    Thompson, Richard
    MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [6] Enhancement of soft-tissue contrast in cone-beam CT using an anti-scatter grid with a sparse sampling approach
    Cho, Sanghoon
    Lim, Sunho
    Kim, Changhwan
    Wi, Sunhee
    Kwon, Taejin
    Youn, Won Sik
    Lee, Sang Hyun
    Kang, Bo Sun
    Cho, Seungryong
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 70 : 1 - 9
  • [7] Dual Energy CT Using Flying Focal Spot and An Anti-Scatter Grid as a Filter
    Hsieh, S.
    Bennett, N.
    Wang, A.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [8] Effects of anti-scatter grid on measurement of detector characteristics
    Liu, X
    Shaw, C
    MEDICAL PHYSICS, 2002, 29 (06) : 1342 - 1342
  • [9] Performance of standard fluoroscopy anti-scatter grids in flat detector based cone beam CT
    Wiegert, J
    Bertram, M
    Schäfer, D
    Conrads, N
    Timmer, J
    Aach, T
    Rose, G
    MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 67 - 78
  • [10] A new high efficiency anti-scatter grid system for mammography
    Gauntt, D
    Barnes, G
    MEDICAL PHYSICS, 2004, 31 (06) : 1787 - 1787