A simulator for mixed Doppler ultrasound signals from pulsatile blood flow and vessel wall with mild stenosis

被引:0
|
作者
Zhang, Yufeng [1 ,2 ]
Gao, Lian [2 ]
Shen, Kai [2 ]
Zhang, Kexin [3 ]
Yan, Jine [2 ]
Cheng, Wei [2 ]
Zhang, Junhua [2 ]
机构
[1] Yunnan Univ, Dept Elect Engn, Kunming 650091, Yunnan, Peoples R China
[2] Yunnan Univ, Dept Elect Engn, Informat Sch, Kunming 650091, Yunnan, Peoples R China
[3] Second Affiliated Hosp, Kunming Med Coll, Cardiovascular Dept, Kunming 650031, Yunnan, Peoples R China
基金
中国国家自然科学基金;
关键词
Mixed Doppler ultrasound signal simulator; Mild local-stenosis; Vessel wall beat; Pulsatile blood flow; ALGORITHM;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A novel computer simulator to generate mixed Doppler ultrasound signals from the pulsatile blood flow and vessel wall with mild stenosis is presented in this paper. In-phase and quadrature Doppler blood flow signals are generated using cosine-superposed components modulated by a spectrogram estimated from velocity profile. Meanwhile, Doppler signals echoed from bidirectional moving walls are generated with the input waveforms of the wall velocities. Finally, the Doppler signals determined above are summed respectively to yield the combined Doppler signals in terms of given sample volume shape. The experimental results show that the proposed simulator generates mixed Doppler signals with the characteristics similar to those found in practice, and could be an useful experimental data source for evaluating the performance of wall filters.
引用
收藏
页码:1903 / 1906
页数:4
相关论文
共 50 条
  • [31] Neural network analysis of Doppler ultrasound blood flow signals: A pilot study
    Wright, IA
    Gough, NAJ
    Rakebrandt, F
    Wahab, M
    Woodcock, JP
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (05): : 683 - 690
  • [32] Pulsatile blood flow in human bone assessed by laser-Doppler flowmetry and the interpretation of photoplethysmographic signals
    Binzoni, Tiziano
    Tchernin, David
    Hyacinthe, Jean-Noel
    Van de Ville, Dimitri
    Richiardi, Jonas
    PHYSIOLOGICAL MEASUREMENT, 2013, 34 (03) : N25 - N40
  • [33] Doppler power variation from porcine blood under steady and pulsatile flow
    Paeng, DG
    Cao, PJ
    Shung, KK
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (09): : 1245 - 1254
  • [34] Cyclic variation of Doppler power from whole blood under pulsatile flow
    Wu, SJ
    Shung, KK
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (07): : 883 - 894
  • [35] Doppler ultrasound signal spectral response in the measurement of the blood flow turbulence caused by stenosis
    Solano, J.
    Vazquez, M.
    Rubio, E.
    Sanchez, I.
    Fuentes, M.
    Garcia, F.
    INTERNATIONAL CONGRESS ON ULTRASONICS, PROCEEDINGS, 2010, 3 (01): : 605 - 613
  • [36] PROCESSING DOPPLER ULTRASOUND SIGNALS FROM BLOOD-BORNE EMBOLI
    SMITH, JL
    EVANS, DH
    FAN, L
    THRUSH, AJ
    NAYLOR, AR
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (05): : 455 - 462
  • [37] SOME ASPECTS OF THE ANALYSIS OF CW DOPPLER ULTRASOUND SIGNALS FOR THE ESTIMATION OF BLOOD-FLOW
    PHILLIPS, PW
    TAYLOR, MG
    PADAYACHEE, TS
    GOSLING, RG
    BRITISH JOURNAL OF RADIOLOGY, 1984, 57 (677): : 452 - 452
  • [38] Ultrasound Doppler measurements of low velocity blood flow: Limitations due to clutter signals from vibrating muscles
    Heimdal, A
    Torp, H
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1997, 44 (04) : 873 - 881
  • [39] Estimation of blood velocity, volumetric flow and wall shear rate using Doppler ultrasound
    Hoskins, Peter R.
    ULTRASOUND, 2011, 19 (03) : 120 - 129
  • [40] Radial distribution of the Doppler power from porcine blood over a pulsatile flow cycle
    Paeng, DG
    Shung, KK
    2001 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2001, : 1281 - 1284