A simulator for mixed Doppler ultrasound signals from pulsatile blood flow and vessel wall with mild stenosis

被引:0
|
作者
Zhang, Yufeng [1 ,2 ]
Gao, Lian [2 ]
Shen, Kai [2 ]
Zhang, Kexin [3 ]
Yan, Jine [2 ]
Cheng, Wei [2 ]
Zhang, Junhua [2 ]
机构
[1] Yunnan Univ, Dept Elect Engn, Kunming 650091, Yunnan, Peoples R China
[2] Yunnan Univ, Dept Elect Engn, Informat Sch, Kunming 650091, Yunnan, Peoples R China
[3] Second Affiliated Hosp, Kunming Med Coll, Cardiovascular Dept, Kunming 650031, Yunnan, Peoples R China
基金
中国国家自然科学基金;
关键词
Mixed Doppler ultrasound signal simulator; Mild local-stenosis; Vessel wall beat; Pulsatile blood flow; ALGORITHM;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A novel computer simulator to generate mixed Doppler ultrasound signals from the pulsatile blood flow and vessel wall with mild stenosis is presented in this paper. In-phase and quadrature Doppler blood flow signals are generated using cosine-superposed components modulated by a spectrogram estimated from velocity profile. Meanwhile, Doppler signals echoed from bidirectional moving walls are generated with the input waveforms of the wall velocities. Finally, the Doppler signals determined above are summed respectively to yield the combined Doppler signals in terms of given sample volume shape. The experimental results show that the proposed simulator generates mixed Doppler signals with the characteristics similar to those found in practice, and could be an useful experimental data source for evaluating the performance of wall filters.
引用
收藏
页码:1903 / 1906
页数:4
相关论文
共 50 条
  • [21] Doppler ultrasound signals simulation from vessels with various stenosis degrees
    Fang, Xin
    Wang, Yuanyuan
    Wang, Weiqi
    ULTRASONICS, 2006, 44 : E173 - E177
  • [22] A viscoelastic model of arterial wall motion in pulsatile flow: implications for Doppler ultrasound clutter assessment
    Warriner, Renee K.
    Johnston, K. Wayne
    Cobbold, Richard S. C.
    PHYSIOLOGICAL MEASUREMENT, 2008, 29 (02) : 157 - 179
  • [23] A recurrent neural network classifier for Doppler ultrasound blood flow signals
    Guler, Inan
    Ubeyli, Elif Derya
    PATTERN RECOGNITION LETTERS, 2006, 27 (13) : 1560 - 1571
  • [24] EFFECT OF PULSATILE ARTERIAL DIAMETER VARIATIONS ON BLOOD-FLOW ESTIMATED BY DOPPLER ULTRASOUND
    ERIKSEN, M
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1992, 30 (01) : 46 - 50
  • [25] Application of Womersley Model to Reconstruct Pulsatile Flow From Doppler Ultrasound Measurements
    Daidzic, Nihad E.
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2014, 136 (04):
  • [26] Color Doppler ultrasound pulsatile flow signals of thoracic lesions: Comparison of lung cancers and benign lesions
    Hsu, WH
    Chiang, CD
    Chen, CY
    Kwan, PC
    Hsu, JY
    Hsu, CP
    Ho, WL
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (08): : 1087 - 1095
  • [27] Dynamic flow US, color Doppler US, and power Doppler US in the assessment of vessel signals of thoracic lesions abutting Pulsatile organs
    Hsu, Wu-Huei
    Tu, Chih-Yen
    Chen, Hung-Jen
    Li, Chien-Te
    Yu, Yang-Hao
    Hang, Liang-Wen
    Chiu, Kuo-Liang
    Hsia, Te-Chun
    ACADEMIC RADIOLOGY, 2008, 15 (03) : 350 - 360
  • [28] Blood Flow Through a Catheterized Artery Having a Mild Stenosis at the Wall with a Blood Clot at the Centre
    Saleem, Anber
    Akhtar, Salman
    Nadeem, Sohail
    Issakhov, Alibek
    Ghalambaz, Mehdi
    CMES-COMPUTER MODELING IN ENGINEERING & SCIENCES, 2020, 125 (02): : 565 - 577
  • [29] Implementing wavelet/probabilistic neural networks for Doppler ultrasound blood flow signals
    Guler, Inan
    Ubeyli, Elif Derya
    EXPERT SYSTEMS WITH APPLICATIONS, 2007, 33 (01) : 162 - 170
  • [30] A mixture of experts network structure for modelling Doppler ultrasound blood flow signals
    Güler, I
    Übeyli, ED
    COMPUTERS IN BIOLOGY AND MEDICINE, 2005, 35 (07) : 565 - 582