Dissatisfaction after multifocal intraocular lens implantation

被引:332
|
作者
Woodward, Maria A. [1 ]
Randleman, J. Bradley [1 ]
Stulting, R. Doyle [1 ]
机构
[1] Emory Eye Ctr & Emory Vis, Atlanta, GA USA
来源
关键词
CONTRAST SENSITIVITY; VISUAL-ACUITY; PUPIL SIZE; BILATERAL IMPLANTATION; OPTICAL-PERFORMANCE; CATARACT-SURGERY; CLINICAL-TRIAL; RESTOR; OUTCOMES; REZOOM;
D O I
10.1016/j.jcrs.2009.01.031
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To analyze the reasons for patient dissatisfaction after phacoemulsification with multifocal intraocular lens (IOL) implantation and the outcomes after intervention. SETTING: Emory Eye Center, Atlanta, Georgia, USA. METHODS: This retrospective review comprised eyes of patients dissatisfied with visual outcomes after multifocal IOL implantation. Outcomes analyzed included type of visual complaint, treatment modality for each complaint, and degree of clinical improvement after intervention. RESULTS: Thirty-two patients (43 eyes) reported unwanted visual symptoms after multifocal IOL implantation, including in 28 eyes (65%) with an AcrySot ReSTOR IOL and 15 (35%) with a ReZoom IOL. Thirty patients (41 eyes) reported blurred vision, 15 (18 eyes) reported photic phenomena, and 13 (16 eyes) reported both. Causes of blurred vision included ametropia (12 eyes, 29%), dry eye syndrome (6 eyes, 15%), posterior capsule opacification (PCO) (22 eyes, 54%), and unexplained etiology (1 eye, 2%). Causes of photic phenomena included IOL decentration (2 eyes, 12%), retained lens fragment (1 eye, 6%), PCO (12 eyes, 66%), dry-eye syndrome (1 eye, 2%), and unexplained etiology (2 eyes, 11%). Photic phenomena attributed to PCO also caused blurred vision. Thirty-five eyes (81%) had improvement with conservative treatment. Five eyes (12%) did not have improvement despite treatment combinations. Three eyes (7%) required IOL exchange. CONCLUSIONS: Complaints of blurred vision and photic phenomena after multifocal IOL implantation were effectively managed with appropriate treatment. Few eyes (7%) required IOL exchange. Neodymium:YAG capsulotomy should be delayed until it has been determined that IOL exchange will not be necessary. i Cataract Refract Surg 2009; 35:992-997 (C) 2009 ASCRS and ESCRS
引用
收藏
页码:992 / 997
页数:6
相关论文
共 50 条
  • [31] Multifocal intraocular lens after LASIK
    Agudelo, LM
    Zapata, LF
    Molina, MC
    Molina, CA
    Donado, JH
    JOURNAL OF REFRACTIVE SURGERY, 2004, 20 (06) : 838 - 839
  • [32] Multifocal intraocular lens implantation in patients with traumatic cataract
    Jacobi, PC
    Dietlein, TS
    Lueke, C
    Jacobi, FK
    OPHTHALMOLOGY, 2003, 110 (03) : 531 - 538
  • [33] Multifocal intraocular lens implantation in pediatric cataract surgery
    Jacobi, PC
    Dietlein, TS
    Konen, W
    OPHTHALMOLOGY, 2001, 108 (08) : 1375 - 1380
  • [34] Clear lens extraction with multifocal apodized diffractive intraocular lens implantation
    Fernandez-Vega, Luis
    Alfonso, Jose F.
    Rodriguez, Pedro P.
    Montes-Mico, Robert
    OPHTHALMOLOGY, 2007, 114 (08) : 1491 - 1498
  • [35] Contrast sensitivity after refractive lens exchange with diffractive multifocal intraocular lens implantation in hyperopic eyes
    Ferrer-Blasco, Teresa
    Montes-Mico, Robert
    Cervino, Alejandro
    Alfonso, Jose F.
    Fernandez-Vega, Luis
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (12): : 2043 - 2048
  • [36] Effect of astigmatism on visual acuity after multifocal versus monofocal intraocular lens implantation
    Berdahl, John P.
    Hardten, David R.
    Kramer, Brent A.
    Potvin, Richard
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (10): : 1192 - 1197
  • [37] Initial Results and Patient Satisfaction After ReSTOR Multifocal TORIC Intraocular Lens Implantation
    Alkharashi, Maan
    Discepola, Marino
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [38] Evaluation of image quality after implantation of 2 diffractive multifocal intraocular lens models
    Castillo-Gomez, Alfredo
    Carmona-Gonzalez, David
    Maria Martinez-de-la-Casa, Jose
    Palomino-Bautista, Carlos
    Garcia-Feijoo, Julian
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (07): : 1244 - 1250
  • [39] Visual outcomes and optical quality after implantation of a diffractive multifocal toric intraocular lens
    Chen, Xiangfei
    Zhao, Ming
    Shi, Yuhua
    Yang, Liping
    Lu, Yan
    Huang, Zhenping
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2016, 64 (04) : 285 - 291
  • [40] Multifocal Intraocular Lens Implantation after Pars Plana Vitrectomy to Treat Retinal Detachment
    Jo, Min Soo
    Kim, Ki Seok
    Chung, Sung Kun
    Kim, Suk Jin
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2022, 63 (10): : 876 - 882