Dissatisfaction after multifocal intraocular lens implantation

被引:332
|
作者
Woodward, Maria A. [1 ]
Randleman, J. Bradley [1 ]
Stulting, R. Doyle [1 ]
机构
[1] Emory Eye Ctr & Emory Vis, Atlanta, GA USA
来源
JOURNAL OF CATARACT AND REFRACTIVE SURGERY | 2009年 / 35卷 / 06期
关键词
CONTRAST SENSITIVITY; VISUAL-ACUITY; PUPIL SIZE; BILATERAL IMPLANTATION; OPTICAL-PERFORMANCE; CATARACT-SURGERY; CLINICAL-TRIAL; RESTOR; OUTCOMES; REZOOM;
D O I
10.1016/j.jcrs.2009.01.031
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To analyze the reasons for patient dissatisfaction after phacoemulsification with multifocal intraocular lens (IOL) implantation and the outcomes after intervention. SETTING: Emory Eye Center, Atlanta, Georgia, USA. METHODS: This retrospective review comprised eyes of patients dissatisfied with visual outcomes after multifocal IOL implantation. Outcomes analyzed included type of visual complaint, treatment modality for each complaint, and degree of clinical improvement after intervention. RESULTS: Thirty-two patients (43 eyes) reported unwanted visual symptoms after multifocal IOL implantation, including in 28 eyes (65%) with an AcrySot ReSTOR IOL and 15 (35%) with a ReZoom IOL. Thirty patients (41 eyes) reported blurred vision, 15 (18 eyes) reported photic phenomena, and 13 (16 eyes) reported both. Causes of blurred vision included ametropia (12 eyes, 29%), dry eye syndrome (6 eyes, 15%), posterior capsule opacification (PCO) (22 eyes, 54%), and unexplained etiology (1 eye, 2%). Causes of photic phenomena included IOL decentration (2 eyes, 12%), retained lens fragment (1 eye, 6%), PCO (12 eyes, 66%), dry-eye syndrome (1 eye, 2%), and unexplained etiology (2 eyes, 11%). Photic phenomena attributed to PCO also caused blurred vision. Thirty-five eyes (81%) had improvement with conservative treatment. Five eyes (12%) did not have improvement despite treatment combinations. Three eyes (7%) required IOL exchange. CONCLUSIONS: Complaints of blurred vision and photic phenomena after multifocal IOL implantation were effectively managed with appropriate treatment. Few eyes (7%) required IOL exchange. Neodymium:YAG capsulotomy should be delayed until it has been determined that IOL exchange will not be necessary. i Cataract Refract Surg 2009; 35:992-997 (C) 2009 ASCRS and ESCRS
引用
收藏
页码:992 / 997
页数:6
相关论文
共 50 条
  • [21] Cyclosporine 0.05% to improve visual outcomes after multifocal intraocular lens implantation
    Donnenfeld, Eric D.
    Solomon, Renee
    Roberts, Calvin W.
    Wittpenn, John R.
    McDonald, Marguerite B.
    Perry, Henry D.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (07): : 1095 - 1100
  • [22] Distance and near contrast sensitivity function after multifocal intraocular lens implantation
    Montés-Micó, R
    Alió, JL
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (04): : 703 - 711
  • [23] Clinical results after implantation of a new segmental refractive multifocal intraocular lens
    Thomas, B. C.
    Auffarth, G. U.
    Philips, R.
    Novak, J.
    Blazek, J.
    Adamkova, H.
    Rabsilber, T. M.
    OPHTHALMOLOGE, 2013, 110 (11): : 1058 - 1062
  • [24] Effect of illumination on visual function after monofocal and multifocal intraocular lens implantation
    M A Elgohary
    A B Beckingsale
    Eye, 2006, 20 : 144 - 149
  • [25] Visual outcomes after implantation of a novel refractive toric multifocal intraocular lens
    Shimoda, Talita
    Shimoda, Gilberto
    Hida, Wilson Takashi
    Nakano, Celso Takashi
    Motta, Antonio Francisco
    Guimaraees, Aline Silva
    Tzelikis, Patrick Frensel M.
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2014, 77 (02) : 71 - 75
  • [26] Effect of illumination on visual function after monofocal and multifocal intraocular lens implantation
    Elgohary, MA
    Beckingsale, AB
    EYE, 2006, 20 (02) : 144 - 149
  • [27] Visual function and mobility after multifocal versus monofocal intraocular lens implantation
    Hall, Courtney D.
    Barnes, Claire S.
    Gutherie, Audrey H.
    Lynch, Mary G.
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2022, 105 (01) : 70 - 76
  • [28] Validity of automated refraction after segmented refractive multifocal intraocular lens implantation
    César Albarrán-Diego
    Gonzalo Mu?oz
    Stephanie Rohrweck
    Santiago García-Lázaro
    José Ricardo Albero
    International Journal of Ophthalmology, 2017, (11) : 1728 - 1733
  • [29] Diffractive multifocal intraocular lens implantation in patients with monofocal intraocular lens in the contralateral eye
    Jae Yong Kim
    Yunhan Lee
    Hun Jae Won
    Hyerin Jeong
    Jin Hyoung Park
    Myoung Joon Kim
    Hungwon Tchah
    International Journal of Ophthalmology, 2020, (05) : 737 - 743
  • [30] Diffractive multifocal intraocular lens implantation in patients with monofocal intraocular lens in the contralateral eye
    Kim, Jae Yong
    Lee, Yunhan
    Won, Hun Jae
    Jeong, Hyerin
    Park, Jin Hyoung
    Kim, Myoung Joon
    Tchah, Hungwon
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2020, 13 (05) : 737 - 743