Dissatisfaction after multifocal intraocular lens implantation

被引:332
|
作者
Woodward, Maria A. [1 ]
Randleman, J. Bradley [1 ]
Stulting, R. Doyle [1 ]
机构
[1] Emory Eye Ctr & Emory Vis, Atlanta, GA USA
来源
关键词
CONTRAST SENSITIVITY; VISUAL-ACUITY; PUPIL SIZE; BILATERAL IMPLANTATION; OPTICAL-PERFORMANCE; CATARACT-SURGERY; CLINICAL-TRIAL; RESTOR; OUTCOMES; REZOOM;
D O I
10.1016/j.jcrs.2009.01.031
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To analyze the reasons for patient dissatisfaction after phacoemulsification with multifocal intraocular lens (IOL) implantation and the outcomes after intervention. SETTING: Emory Eye Center, Atlanta, Georgia, USA. METHODS: This retrospective review comprised eyes of patients dissatisfied with visual outcomes after multifocal IOL implantation. Outcomes analyzed included type of visual complaint, treatment modality for each complaint, and degree of clinical improvement after intervention. RESULTS: Thirty-two patients (43 eyes) reported unwanted visual symptoms after multifocal IOL implantation, including in 28 eyes (65%) with an AcrySot ReSTOR IOL and 15 (35%) with a ReZoom IOL. Thirty patients (41 eyes) reported blurred vision, 15 (18 eyes) reported photic phenomena, and 13 (16 eyes) reported both. Causes of blurred vision included ametropia (12 eyes, 29%), dry eye syndrome (6 eyes, 15%), posterior capsule opacification (PCO) (22 eyes, 54%), and unexplained etiology (1 eye, 2%). Causes of photic phenomena included IOL decentration (2 eyes, 12%), retained lens fragment (1 eye, 6%), PCO (12 eyes, 66%), dry-eye syndrome (1 eye, 2%), and unexplained etiology (2 eyes, 11%). Photic phenomena attributed to PCO also caused blurred vision. Thirty-five eyes (81%) had improvement with conservative treatment. Five eyes (12%) did not have improvement despite treatment combinations. Three eyes (7%) required IOL exchange. CONCLUSIONS: Complaints of blurred vision and photic phenomena after multifocal IOL implantation were effectively managed with appropriate treatment. Few eyes (7%) required IOL exchange. Neodymium:YAG capsulotomy should be delayed until it has been determined that IOL exchange will not be necessary. i Cataract Refract Surg 2009; 35:992-997 (C) 2009 ASCRS and ESCRS
引用
收藏
页码:992 / 997
页数:6
相关论文
共 50 条
  • [1] Dissatisfaction after multifocal intraocular lens implantation
    Tarib, Imane
    Asroui, Lara
    Ferguson, Tanner
    Randleman, James
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [2] Dissatisfaction After Bilateral Multifocal Intraocular Lens Implantation: An Electrophysiology Study
    Shimizu, Kimiya
    Ito, Misae
    JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (04) : 309 - 312
  • [3] Dissatisfaction after implantation of multifocal intraocular lenses
    Bonnet, Clemence
    Brezin, Antoine P.
    Monnet, Dominique
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [4] Dissatisfaction after implantation of multifocal intraocular lenses
    de Vries, Niels E.
    Webers, Carroll A. B.
    Touwslager, Wouter R. H.
    Bauer, Noel J. C.
    de Brabander, John
    Berendschot, Tos T.
    Nuijts, Rudy M. M. A.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (05): : 859 - 865
  • [5] Managing dissatisfaction after multifocal intraocular lens implantation through lens exchange using monofocal or alternative multifocal IOLs
    Al-Shymali, Olena
    Canto, Mario
    Alio del Barrio, Jorge L.
    McAlinden, Colm
    Yebana, Pilar
    Alio, Jorge L.
    ACTA OPHTHALMOLOGICA, 2024, 102 (07) : e1040 - e1049
  • [6] Retreatments after multifocal intraocular lens implantation: an analysis
    Gundersen, Kjell Gunnar
    Makari, Sarah
    Ostenstad, Steffen
    Potvin, Rick
    CLINICAL OPHTHALMOLOGY, 2016, 10 : 365 - 371
  • [7] Halo size after implantation of a multifocal intraocular lens
    Perez Carrasco, M. J.
    Alvarez-Rementeria, L.
    Hurtado-Cena, F. J.
    Heredia-Tejado, L.
    Dorado-Palacios, F. I.
    Puell, M. C.
    ACTA OPHTHALMOLOGICA, 2013, 91
  • [8] Piggyback Intraocular Lens Implantation to Correct Pseudophakic Refractive Error After Segmental Multifocal Intraocular Lens Implantation
    Venter, Jan A.
    Oberholster, Andre
    Schallhorn, Steven C.
    Pelouskova, Martina
    JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (04) : 234 - 239
  • [9] Refractive outcomes after bilateral multifocal intraocular lens implantation
    Pineda-Fernández, A
    Jaramillo, J
    Celis, V
    Vargas, J
    DiStacio, M
    Galíndez, A
    Del Valle, M
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (03): : 685 - 688
  • [10] Comparison of Visual Performance and Patient Satisfaction After Multifocal Intraocular Lens Implantation and During Multifocal Contact Lens Wear After Monofocal Intraocular Lens Implantation: A Pilot Study
    Kazutaka Kamiya
    Kei Iijima
    Takahiro Hiraoka
    Keita Takada
    Yosai Mori
    Kazunori Miyata
    Ophthalmology and Therapy, 2021, 10 : 1119 - 1128