Measuring visual acuity - Mesopic or photopic conditions, and high or low contrast letters?

被引:0
|
作者
Pesudovs, K [1 ]
Marsack, JD
Donnelly, WJ
Thibos, LN
Applegate, RA
机构
[1] Univ Houston, Coll Optometry, Visual Opt Inst, Houston, TX 77204 USA
[2] Indiana Univ, Sch Optometry, Bloomington, IN USA
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To develop single-valued wavefront aberration metrics that correlate strongly with visual performance. The purpose of this study is to explore whether photopic high contrast visual acuity (VA) is an appropriate visual performance reference and whether mesopic and/or low contrast testing provides any advantage. METHODS: Subjects from the Texas Investigation of Cataract Optics study (N = 148) ranged in age from 21.6 to 83.8 years and from clear lens to dense nuclear cataract. Visual acuity was measured under four conditions: photopic high (VA(PHC)) and low (VA(PLC)) contrast, mesopic high (VA(MHC)) and low (VA(MLC)) contrast (photopic = 280 cd/m(2), mesopic = 0.75 cd/m(2)). Variables were tested for compliance with normality (-2.00 < skew and kurtosis < 2.00) and transformed if required. Linear regression and Bland-Altman 95% limits of agreement (+/-1.96 SD) were used to examine relationships between VA variables and between VA and wavefront aberration metrics. RESULTS. The two photopic measures VA(PHC) (skew = 2.57, kurtosis = 12.2) and VA(PLC) (1.67, 5.41) were poorly distributed, but the two mesopic measures VA(MHC) (0.88, 1.67) and VA(MLC) (0.29, -0.18) were normally distributed. Strong correlations existed between the (transformed) VA variables (R: 0.53 to 0.84). However, limits of agreement ranged over 0.30 to 0.42 logMAR, whereas retest data suggested a range of 0.15. All four were offered in stepwise multiple linear regression for 30 wavefront metrics: 20 included VA(MLC) alone, two included VA(PLC), two included VA(MHC) and six included both VA(MLC) and VA(MHC); R-2 averaged 25%. CONCLUSION: Although strongly correlated, low contrast and/or mesopic VA testing provides different information. Wave aberration metrics correlate better with VA(MLC) making this the visual performance test of choice.
引用
收藏
页码:S508 / S514
页数:7
相关论文
共 50 条
  • [41] Crowding can impact both low and high contrast visual acuity measurements
    František Pluháček
    John Siderov
    Ivana Macháčová
    Scientific Reports, 12
  • [42] Assessment of high and low contrast visual acuity after photorefractive keratectomy for myopia
    Gauthier, CA
    Holden, BA
    Epstein, D
    Tengroth, B
    Fagerholm, P
    Hamberg-Nystrom, H
    OPTOMETRY AND VISION SCIENCE, 1998, 75 (08) : 585 - 590
  • [43] Crowding can impact both low and high contrast visual acuity measurements
    Pluhacek, Frantisek
    Siderov, John
    Machacova, Ivana
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [44] Observers' Judgments of the Effects of Glare on Their Visual Acuity for High and Low Contrast Stimuli
    Sewall, Ashley A. Stafford
    Borzendowski, Stephanie A. Whetsel
    Tyrrell, Richard A.
    Stephens, Benjamin R.
    Rosopa, Patrick J.
    PERCEPTION, 2016, 45 (07) : 755 - 767
  • [45] HIGH AND LOW CONTRAST ACUITY - REPLY
    BROWN, B
    LOVIEKITCHIN, JE
    OPTOMETRY AND VISION SCIENCE, 1990, 67 (08) : 654 - 656
  • [46] Reliability of Mesopic Measures of Visual Acuity and Contrast Sensitivity and Their Correlation with Rod and Cone Function in Retinitis Pigmentosa
    Bittner, Ava K.
    Ferraz, Mariana C.
    OPHTHALMIC RESEARCH, 2020, 63 (02) : 133 - 140
  • [47] Low contrast visual acuity is decreased in patients with parkinsonism
    Sheriff, C.
    Novaro, S.
    Maitland, C. G.
    Specht, J.
    MOVEMENT DISORDERS, 2011, 26 : S134 - S134
  • [48] Low contrast visual acuity and glare in keratoplasty.
    Fontaine, N
    Boisjoly, HM
    Gresset, J
    Charest, M
    Brunette, I
    LeFrancois, M
    Deschênes, J
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S883 - S883
  • [49] MEASURING VISUAL-ACUITY IN GENERAL-PRACTICE - MANY REFERRAL LETTERS OMIT VISUAL-ACUITY MEASUREMENT
    RAO, GP
    MORIARTY, AP
    BRITISH MEDICAL JOURNAL, 1995, 310 (6980): : 671 - 671
  • [50] Effect of a yellow filter on contrast sensitivity and disability glare after laser in situ keratomileusis under mesopic and photopic conditions
    Pérez-Carrasco, MJ
    Puell, MC
    Sánchez-Ramos, C
    López-Castro, A
    Langa, A
    JOURNAL OF REFRACTIVE SURGERY, 2005, 21 (02) : 158 - 165