Measuring visual acuity - Mesopic or photopic conditions, and high or low contrast letters?

被引:0
|
作者
Pesudovs, K [1 ]
Marsack, JD
Donnelly, WJ
Thibos, LN
Applegate, RA
机构
[1] Univ Houston, Coll Optometry, Visual Opt Inst, Houston, TX 77204 USA
[2] Indiana Univ, Sch Optometry, Bloomington, IN USA
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To develop single-valued wavefront aberration metrics that correlate strongly with visual performance. The purpose of this study is to explore whether photopic high contrast visual acuity (VA) is an appropriate visual performance reference and whether mesopic and/or low contrast testing provides any advantage. METHODS: Subjects from the Texas Investigation of Cataract Optics study (N = 148) ranged in age from 21.6 to 83.8 years and from clear lens to dense nuclear cataract. Visual acuity was measured under four conditions: photopic high (VA(PHC)) and low (VA(PLC)) contrast, mesopic high (VA(MHC)) and low (VA(MLC)) contrast (photopic = 280 cd/m(2), mesopic = 0.75 cd/m(2)). Variables were tested for compliance with normality (-2.00 < skew and kurtosis < 2.00) and transformed if required. Linear regression and Bland-Altman 95% limits of agreement (+/-1.96 SD) were used to examine relationships between VA variables and between VA and wavefront aberration metrics. RESULTS. The two photopic measures VA(PHC) (skew = 2.57, kurtosis = 12.2) and VA(PLC) (1.67, 5.41) were poorly distributed, but the two mesopic measures VA(MHC) (0.88, 1.67) and VA(MLC) (0.29, -0.18) were normally distributed. Strong correlations existed between the (transformed) VA variables (R: 0.53 to 0.84). However, limits of agreement ranged over 0.30 to 0.42 logMAR, whereas retest data suggested a range of 0.15. All four were offered in stepwise multiple linear regression for 30 wavefront metrics: 20 included VA(MLC) alone, two included VA(PLC), two included VA(MHC) and six included both VA(MLC) and VA(MHC); R-2 averaged 25%. CONCLUSION: Although strongly correlated, low contrast and/or mesopic VA testing provides different information. Wave aberration metrics correlate better with VA(MLC) making this the visual performance test of choice.
引用
收藏
页码:S508 / S514
页数:7
相关论文
共 50 条
  • [31] Binocular Summation of Visual Acuity at High and Low Contrast in Early Glaucoma
    Leibovitzh, Galia Issashar
    Trope, Graham E.
    Buys, Yvonne M.
    Tarita-Nistor, Luminita
    JOURNAL OF GLAUCOMA, 2023, 32 (02) : 133 - 138
  • [32] Changes in high and low contrast logMAR visual acuity with overnight orthokeratology
    Rah, MJ
    Bailey, MD
    Jones, LA
    Jackson, JM
    Marsden, HJ
    Barr, JT
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U864 - U864
  • [33] High and Low Contrast Visual Acuity Are Not Affected in Amyotrophic Lateral Sclerosis
    Moss, Heather E.
    Samelson, Monica
    Mohan, Girish
    Jiang, Qin Li
    PLOS ONE, 2016, 11 (12):
  • [34] Low-contrast visual acuity versus low-luminance visual acuity in choroideremia
    Wood, Laura J.
    Jolly, Jasleen K.
    Andrews, Colm D.
    Wilson, Iain R.
    Hickey, Doron
    Cehajic-Kapetanovic, Jasmina
    MacLaren, Robert E.
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2021, 104 (01) : 90 - 94
  • [35] Assessment of high and low contrast visual acuity after photorefractive keratectomy
    Gauthier, CA
    Holden, BA
    Epstein, D
    Tengroth, B
    Fagerholm, P
    HambergNystrom, H
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 79 - 79
  • [36] Degradation of Photopic and Mesopic Contrast Sensitivity Function in High Myopes With Partial Posterior Vitreous Detachment
    Zhao, Jian
    Xiao, Minzhi
    Zhu, Ye
    Gong, Qianwen
    Qu, Jia
    Lu, Fan
    Hu, Liang
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2024, 13 (04):
  • [37] Measurement of contrast vision: mesopic or photopic vision? Comparison of different methods for measuring contrast sensitivity within the framework of driving licence regulations
    Bergmann, L. C. E.
    Darius, S.
    Kropf, S.
    Boeckelmann, I.
    OPHTHALMOLOGE, 2016, 113 (10): : 844 - 851
  • [38] Photopic, Mesopic, and Scotopic Visual Acuity After 18 mW/cm2 Accelerated Corneal Cross-Linking
    Asgari, Soheila
    Hashemi, Hassan
    Miraftab, Mohammad
    Shahhoseini, Saied
    Jafarzadhpur, Ebrahim
    Mehravaran, Shiva
    Fotouhi, Akbar
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2018, 44 : S185 - S189
  • [39] Effect of reduced contrast on visual acuity as measured with Snellen test letters
    Ludvigh, E
    ARCHIVES OF OPHTHALMOLOGY, 1941, 25 (03) : 469 - 474
  • [40] Contrast sensitivity for flickering and static letters and visual acuity at isoluminance in glaucoma
    Swindale, NV
    Fendick, MG
    Drance, SM
    Graham, SL
    Hnik, P
    JOURNAL OF GLAUCOMA, 1996, 5 (03) : 156 - 169