Using electropolymerized non-conducting polymers to develop enzyme amperometric biosensors

被引:109
|
作者
Miao, YQ [1 ]
Chen, JR [1 ]
Wu, XH [1 ]
机构
[1] Zhejiang Normal Univ, Coll Chem & Life Sci, Jinhua 321004, Peoples R China
关键词
D O I
10.1016/j.tibtech.2004.03.004
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The response performance of amperometric biosensors can be likened to that of an uncovered electrode because the non-conducting polymer films used to develop these biosensors are very thin (10-100 nm), owing to their self-limited growth. The non-conducting polymer films also have favorable permselective properties, which could be used to eliminate possible electrochemical interference in samples. Composite structures or materials that include non-conducting polymers of, for example, phenol and its derivatives, phenylenediamines, and overoxidized or electroinactive polypyrrole could be used to optimize the biosensors. This article will discuss these issues, as well as the use of quartz crystal microbalance in the study of non-conducting-polymer-based biosensors.
引用
收藏
页码:227 / 231
页数:5
相关论文
共 50 条
  • [31] Interferent suppression using a novel polypyrrole-containing hydrogel in amperometric enzyme biosensors
    Brahim, S
    Narinesingh, D
    Giuseppi-Elie, A
    ELECTROANALYSIS, 2002, 14 (09) : 627 - 633
  • [32] DIRECT AMPEROMETRIC BIOSENSORS FROM ENZYME-CONTAINING CROSS-LINKED REDOX POLYMERS BOUND TO ELECTRODES
    GREGG, BA
    HELLER, A
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1989, 198 : 2 - ANYL
  • [33] Enhanced Antimicrobial Activity on Non-Conducting and Conducting Air Filters by Using Air Ions and Grapefruit Seed Extract
    Woo, Chang Gyu
    Kim, Hak-Joon
    Kim, Yong-Jin
    Han, Bangwoo
    AEROSOL AND AIR QUALITY RESEARCH, 2017, 17 (07) : 1917 - 1924
  • [34] A new interference-free lysine biosensor using a non-conducting polymer film
    Curulli, A
    Kelly, S
    O'Sullivan, C
    Guilbault, GG
    Palleschi, G
    BIOSENSORS & BIOELECTRONICS, 1998, 13 (12): : 1245 - 1250
  • [35] A new interference-free lysine biosensor using a non-conducting polymer film
    Curulli, A.
    Kelly, S.
    O'Sullivan, C.
    Guilbault, G.G.
    Palleschi, G.
    Biosensors and Bioelectronics, 1998, 13 (12): : 1245 - 1250
  • [36] Performance characteristic studies of glucose biosensors modified by (3-mercaptopropyl)trimethoxysilane sol-gel and non-conducting polyaniline
    Yang, Yang-Li
    Tseng, Ta-Feng
    Yeh, Jui-Ming
    Chen, Chien-An
    Lou, Shyh-Liang
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 131 (02) : 533 - 540
  • [37] Modeling electrophoretic deposition on porous non-conducting substrates using statistical design of experiments
    Compson, Charles
    Liu, Meilin
    Besra, Laxmidhar
    Earl, David
    JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 2006, 89 (09) : 2787 - 2795
  • [38] Conducting to non-conducting transition in dual transmission lines using a ternary model with long-range correlated disorder
    Lazo, E.
    Diez, E.
    PHYSICS LETTERS A, 2010, 374 (34) : 3538 - 3545
  • [39] AMPEROMETRIC ENZYME SENSOR USING CONDUCTING ORGANIC SALT-CONTAINING POLYPYRROLE MATRIX
    BEGUM, A
    TSUSHIMA, H
    SUZAWA, T
    SHINOHARA, H
    IKARIYAMA, Y
    AIZAWA, M
    SENSORS AND ACTUATORS B-CHEMICAL, 1993, 14 (1-3) : 576 - 577
  • [40] CUTTING X-RAY-ALIGNED NON-CONDUCTING CRYSTALS USING A SPARK EROSION MACHINE
    HEATH, M
    ROYS, WB
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1979, 12 (09): : 808 - 808