While the process of IMRT planning involves optimization of the dose distribution, the procedure for selecting the beam inputs for this process continues to be largely trial-and-error. We have developed an integer programming (IP) optimization method to optimize beam orientation using mean organ-at-risk (MOD) data from single-beam plans. Two test cases were selected in which one organ-at-risk (OAR) and four OARs were simulated, respectively, along with a PTV. Beam orientation space was discretized in 10degrees increments. For each beam orientation, a single-beam plan without intensity modulation and without constraints on OAR dose was generated and normalized to yield a mean PTV dose of 2 Gy and the corresponding MOD was calculated. The degree of OAR sparing was related to the average OAR MODs resulting from the beam orientations utilized with improvements of up to 10% at some dose levels. On the other hand, OAR DVHs in the IMRT plans were insensitive to beam numbers (in the 6-9 range) for similar average single-beam MODs. These MOD data were input to an IP optimization process, which then selected specified numbers of beam angles as inputs to a treatment planning system. Our results show that sets of beam angles with lower average single-beam MODs produce IMRT plans with better OAR sparing than manually selected beam angles. To optimize beam orientations, weights were assigned to each OAR following MOD input to the IP which was subsequently solved using the branch-and-cut algorithm. Seven-beam orientations obtained from solving the IP were applied to the test case with four OARs and the resulting plan with a dose prescription of 63 Gy was compared with an equi-spaced beam plan. The IP selected beams produced dose-volume improvements of up to 40% for OARs proximal to the PTV Further improvement in the DVH can be obtained by increasing the weights assigned to these OARs but at the expense of the remaining OARs.
引用
收藏
页码:3465 / 3481
页数:17
相关论文
共 50 条
  • [1] Optimal selection of beam orientations in intensity-modulated radiation therapy
    Wen, Ue-Pyng
    Yu, Ru-Siou
    Tsui, Che-Wei
    JOURNAL OF INDUSTRIAL AND PRODUCTION ENGINEERING, 2011, 28 (04) : 316 - 326
  • [2] Beam orientation optimization for intensity-modulated radiation therapy using mixed integer programming
    Yang, Ruijie
    Dai, Jianrong
    Yang, Yong
    Hu, Yimin
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (15): : 3653 - 3666
  • [3] Beam orientation optimization for intensity-modulated radiation therapy using mixed integer programming
    Yang, Ruijie
    Dai, Jianrong
    Yang, Yong
    Hu, Yimin
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1758 - +
  • [4] Computer-assisted selection of coplanar beam orientations in intensity-modulated radiation therapy
    Pugachev, A
    Xing, L
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (09): : 2467 - 2476
  • [5] Direct-aperture optimization applied to selection of beam orientations in intensity-modulated radiation therapy
    Bedford, J. L.
    Webb, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (02): : 479 - 498
  • [6] Dose–volume histogram evaluation scheme for beam orientations in intensity-modulated radiation therapy
    Ahmad-Saher Azizi-Sultan
    Computational and Applied Mathematics, 2018, 37 : 191 - 204
  • [7] Conical beam geometry intensity-modulated radiation therapy
    Schuler, Emil
    Wang, Lei
    Loo, Billy W., Jr.
    Maxim, Peter G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (12):
  • [8] Integer Programming Applied to Intensity-Modulated Radiation Therapy Treatment Planning
    Eva K. Lee
    Tim Fox
    Ian Crocker
    Annals of Operations Research, 2003, 119 : 165 - 181
  • [9] Integer programming applied to intensity-modulated radiation therapy treatment planning
    Lee, EK
    Fox, T
    Crocker, I
    ANNALS OF OPERATIONS RESEARCH, 2003, 119 (1-4) : 165 - 181
  • [10] Dose-volume histogram evaluation scheme for beam orientations in intensity-modulated radiation therapy
    Azizi-Sultan, Ahmad-Saher
    COMPUTATIONAL & APPLIED MATHEMATICS, 2018, 37 (01): : 191 - 204