Conical beam geometry intensity-modulated radiation therapy

被引:6
|
作者
Schuler, Emil [1 ]
Wang, Lei [1 ]
Loo, Billy W., Jr. [1 ,3 ]
Maxim, Peter G. [2 ]
机构
[1] Stanford Univ, Dept Radiat Oncol, Sch Med, Stanford, CA 94305 USA
[2] Indiana Univ Sch Med, Dept Radiat Oncol, Indianapolis, IN 46202 USA
[3] Stanford Univ, Sch Med, Stanford Canc Inst, Stanford, CA 94305 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2019年 / 64卷 / 12期
关键词
treatment planning; non-coplanar geometry; conical beams; PROTON THERAPY; LEAF WIDTH; RADIOTHERAPY; VMAT; CANCER; HEAD; OPTIMIZATION; QUALITY; IMPACT; RISK;
D O I
10.1088/1361-6560/ab246f
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Most commonly in radiation therapy, treatments are delivered in a co-planar geometry. Numerous advantages have been reported of adding non-coplanar beams to the treatment plan. The aim of this study was to compare current state-of-the-art VMAT and CyberKnife treatment plans to that of a novel linac design developed at Stanford which utilizes a static conical beam arrangement that allows the inclusion of a full ring diagnostic CT with shared isocenter with the treatment beams. Four clinical cases, prostate, lung, head/neck, and pediatric brain, were selected and treatment plans were generated with 45 or 60 (to the longitudinal axis of the patient) conical beam IMRT and compared with co-planar 90 VMAT plans. Double cone, with beams entering from both superior and inferior directions, and single cone geometries were evaluated. Plans were optimized in RayStation using an in-house developed script to minimize operator bias between the different techniques. Non-coplanar CyberKnife IMRT plans for the pediatric and prostate case were optimized separately in MultiPlan and compared to conical geometry plans. In the prostate case, increased mean dose to the rectum (2.3-3.7 Gy) and bladder (9.5-14.5 Gy) but decreased dose to the femoral heads (femurs) (7.1-10 Gy) were found with the conical arrangement compared to 90 VMAT. Only minor dosimetric differences were found in the lung case, while selective sparing of organs at risk was found with 45 degrees or 60 degrees conical arrangement in the pediatric brain and head/neck cases. For the prostate case, a reduction in mean doses to the bladder and rectum of 6% (2 Gy) and 18% (5.2 Gy), respectively, was found when comparing the CyberKnife to the 60 degrees conical plan, in favor of the CyberKnife plan, but with an increase in integral dose and reduced conformity. An increase in integral dose and reduced conformity was also found for the pediatric brain case when comparing CyberKnife and 60 degrees conical plan. Minor benefits were found with double cone compared to single cone geometry. Comparable treatment plan quality could be achieved between conical beam arrangement and 90 degrees (coplanar) VMAT and CyberKnife (non-coplanar) IMRT, demonstrating the promise of this novel beam geometry. The use of this beam geometry allows volumetric image-guidance with full ring imaging and a common isocenter for simultaneous treatment and imaging.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Simultaneous beam geometry and intensity map optimization in intensity-modulated radiation therapy
    Lee, EK
    Fox, T
    Crocker, I
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (01): : 301 - 320
  • [2] Comparison of Intensity-Modulated Radiation Therapy, Intensity-Modulated Arc Therapy and Arc-Modulated Radiation Therapy
    Tang, G.
    Earl, M.
    Luan, S.
    Wang, C.
    Naqvi, S.
    Yu, C.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [3] Intensity-modulated radiation therapy
    Lewin, DI
    COMPUTING IN SCIENCE & ENGINEERING, 2002, 4 (05) : 8 - 10
  • [4] Intensity-modulated radiation therapy
    Purdy, JA
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (04): : 845 - 846
  • [5] Intensity-modulated radiation therapy
    Anon
    Computing in Science and Engineering, 2002, 4 (05):
  • [6] Intensity-modulated radiation therapy
    不详
    CURRENT PROBLEMS IN CANCER, 2004, 28 (02) : 47 - 84
  • [7] Intensity-modulated radiation therapy
    Carpini, DD
    HEALTH PHYSICS, 2001, 81 (04): : 469 - 469
  • [8] Intensity-modulated radiation therapy
    Lee, N. Y.
    Terezakis, S. A.
    JOURNAL OF SURGICAL ONCOLOGY, 2008, 97 (08) : 691 - 696
  • [9] Role of beam orientation optimization in intensity-modulated radiation therapy
    Pugachev, A
    Li, JG
    Boyer, AL
    Hancock, SL
    Le, QT
    Donaldson, SS
    Xing, L
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 50 (02): : 551 - 560
  • [10] Decoding the Beam Complexity in Intensity-Modulated Radiation Therapy Plans
    Du, W.
    Cho, S.
    Zhang, X.
    Hoffman, K.
    Kudchadker, R.
    MEDICAL PHYSICS, 2014, 41 (06) : 305 - 305