Non-contact laser/EMAT measurement systems for ultrasound B-scan imaging

被引:0
|
作者
Dewhurst, RJ [1 ]
Murray, PR [1 ]
机构
[1] UMIST, Dept Instrumentat & Analyt Sci, Manchester M60 1QD, Lancs, England
关键词
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
For non-contact non-destructive evaluation (NDE), a laser/EMAT system is an alternative to a more expensive all optical laser-ultrasound system. Several design options of the electromagnetic acoustic transducer (EMAT) are available, permitting inspection of electrically conducting materials. In this paper, we describe a system capable of monitoring variation in either sample thickness or defects, with time-of-flight diffraction arising from mode-converted ultrasonic waves, In a B-scan imaging configuration, quantitative time-of-flight analysis of laser-generated acoustic waves is shown to be an effective method for measurement. Various images will be presented together with an interpretation of their features. For these images, transient laser pulses with typical energies of similar to18mJ have been delivered to the material surface via an optical fiber and focused to a line source by a cylindrical lens. Acoustic waves arising from this excitation propagated through the sample to be reflected from the far surface. Waves returning to the surface, including L-S and S-L mode-converted waves, were detected using an EMAT sensitive to in-plane motion. B-scans have been generated as the sensor head moved along the material's surface, forming a 2-D intensity profile that made changes in plate thickness easy to visualize. Both L-S and S-L mode-converted waves provided a method of simultaneously monitoring two different points on the far surface enabling any changes in the material thickness to be clearly identified.
引用
收藏
页码:348 / 355
页数:8
相关论文
共 50 条
  • [21] B-SCAN ULTRASOUND FOR CARDIAC DIAGNOSIS
    GEHRKE, J
    PRIDIE, RB
    BRITISH JOURNAL OF RADIOLOGY, 1975, 48 (575): : 952 - 952
  • [22] B-SCAN ULTRASOUND IN DIAGNOSIS OF HYDRONEPHROSIS
    SANDERS, RC
    BEARMAN, S
    RADIOLOGY, 1973, 108 (02) : 375 - 382
  • [23] SYMPOSIUM ON B-SCAN ULTRASOUND - FOREWORD
    SANDERS, RC
    RADIOLOGIC CLINICS OF NORTH AMERICA, 1975, 13 (03) : 389 - 390
  • [24] WHATS NEW IN B-SCAN ULTRASOUND
    POUJOL, J
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 1979, 2 (05): : 363 - 368
  • [25] ULTRASOUND B-SCAN ASSESSMENT PROGRAM
    BERSON, AS
    ATHEROSCLEROSIS REVIEWS, 1983, 10 : 169 - 174
  • [26] DETECTION OF PATHOLOGICAL CHANGE IN DYSTROPHIC MUSCLE WITH B-SCAN ULTRASOUND IMAGING
    HECKMATT, JZ
    DUBOWITZ, V
    LEEMAN, S
    LANCET, 1980, 1 (8183): : 1389 - 1390
  • [27] ULTRASOUND B-SCAN IMAGING OF CAROTID-ARTERY ATHEROSCLEROTIC LESIONS
    EVANS, TC
    SANDOK, BA
    GREENLEAF, JF
    HATTERY, RR
    HARRISON, CE
    KOTTKE, BA
    CIRCULATION, 1976, 54 (04) : 219 - 219
  • [28] A non-contact laser probe in industrial measurement
    Li, Y
    Zhang, LX
    Zhang, SL
    Han, YM
    1999 INTERNATIONAL CONFERENCE ON INDUSTRIAL LASERS (IL'99), 1999, 3862 : 306 - 310
  • [29] Non-contact temperature measurement by laser technology
    Huang, Fang
    Liu, Xiangxin
    Han, Junfeng
    Wang, Jing
    Li, Hui
    Wang, Wenjing
    Zhenkong Kexue yu Jishu Xuebao/Journal of Vacuum Science and Technology, 2013, 33 (07): : 642 - 646
  • [30] CONTACT B-SCAN ULTRASOUND EVALUATION OF POSTERIOR VITREOUS DETACHMENT IN EMMETROPIC EYES
    PERICHON, JY
    BRASSEUR, G
    UZZAN, J
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 1993, 16 (10): : 538 - 544