Non-contact laser/EMAT measurement systems for ultrasound B-scan imaging

被引:0
|
作者
Dewhurst, RJ [1 ]
Murray, PR [1 ]
机构
[1] UMIST, Dept Instrumentat & Analyt Sci, Manchester M60 1QD, Lancs, England
关键词
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
For non-contact non-destructive evaluation (NDE), a laser/EMAT system is an alternative to a more expensive all optical laser-ultrasound system. Several design options of the electromagnetic acoustic transducer (EMAT) are available, permitting inspection of electrically conducting materials. In this paper, we describe a system capable of monitoring variation in either sample thickness or defects, with time-of-flight diffraction arising from mode-converted ultrasonic waves, In a B-scan imaging configuration, quantitative time-of-flight analysis of laser-generated acoustic waves is shown to be an effective method for measurement. Various images will be presented together with an interpretation of their features. For these images, transient laser pulses with typical energies of similar to18mJ have been delivered to the material surface via an optical fiber and focused to a line source by a cylindrical lens. Acoustic waves arising from this excitation propagated through the sample to be reflected from the far surface. Waves returning to the surface, including L-S and S-L mode-converted waves, were detected using an EMAT sensitive to in-plane motion. B-scans have been generated as the sensor head moved along the material's surface, forming a 2-D intensity profile that made changes in plate thickness easy to visualize. Both L-S and S-L mode-converted waves provided a method of simultaneously monitoring two different points on the far surface enabling any changes in the material thickness to be clearly identified.
引用
收藏
页码:348 / 355
页数:8
相关论文
共 50 条
  • [11] B-SCAN ULTRASOUND IN OPHTHALMOLOGY
    SHAPIRO, I
    MINNESOTA MEDICINE, 1975, 58 (05) : 379 - 382
  • [12] B-SCAN ULTRASOUND IN DERMATOLOGY
    STRASSER, W
    VANSCHEIDT, W
    HAGEDORN, M
    WOKALEK, H
    FORTSCHRITTE DER MEDIZIN, 1986, 104 (25) : 495 - 498
  • [13] MEASUREMENT OF FETAL BODY DIMENSIONS BY ULTRASOUND B-SCAN METHOD
    YLOSTALO, P
    ANNALES CHIRURGIAE ET GYNAECOLOGIAE, 1974, 63 (01) : 20 - 23
  • [14] NON-CONTACT LASER MEASUREMENT DEVICE
    Vlk, Lukas
    XXIV. MEDZINARODNA KONFERENCIA SUCASNE PROBLEMY V KOLAJAVYCH VOZIDLACH, DIEL II, 2019, : 329 - 336
  • [15] DIRECT CONTACT B-SCAN ULTRASOUND IN THE DIAGNOSIS OF SOLID BREAST MASSES
    GUYER, PB
    DEWBURY, KC
    WARWICK, D
    SMALLWOOD, J
    TAYLOR, I
    CLINICAL RADIOLOGY, 1986, 37 (05) : 451 - 458
  • [16] SYSTEMATIC ULTRASOUND IMAGING OF THE LATERAL VENTRICLES - A-SCAN VERSUS B-SCAN
    LAUB, MC
    INGRISCH, H
    MONATSSCHRIFT KINDERHEILKUNDE, 1984, 132 (05) : 286 - 289
  • [17] COMPLEMENTARY USE OF B-SCAN ULTRASOUND AND RADIONUCLIDE IMAGING TECHNIQUES
    SANDERS, AD
    SANDERS, RC
    JOURNAL OF NUCLEAR MEDICINE, 1977, 18 (03) : 205 - 220
  • [18] STORAGE AND NON-STORAGE SCOPES IN ULTRASOUND B-SCAN
    BALLAS, S
    PEYSER, MR
    HAREFUAH, 1977, 92 (07) : 304 - 305
  • [19] Non-contact biomedical photoacoustic and ultrasound imaging
    Rousseau, Guy
    Gauthier, Bruno
    Blouin, Alain
    Monchalin, Jean-Pierre
    JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (06)
  • [20] The feasibility of non-contact ultrasound for medical imaging
    Clement, G. T.
    Nomura, H.
    Adachi, H.
    Kamakura, T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (18): : 6263 - 6278