Gold nanoparticles plated porous silicon nanopowder for nonenzymatic voltammetric detection of hydrogen peroxide

被引:20
|
作者
Rashed, Md. A. [1 ,7 ]
Harraz, Farid A. [1 ,4 ]
Faisal, M. [1 ,2 ]
El-Toni, Ahmed Mohamed [3 ]
Alsaiari, Mabkhoot [1 ,5 ]
Al-Assiri, M. S. [1 ,6 ]
机构
[1] Najran Univ, Adv Mat & Nanores Ctr, Promising Ctr Sensors & Elect Devices PCSED, POB 1988, Najran 11001, Saudi Arabia
[2] Najran Univ, Fac Sci & Arts, Dept Chem, Najran, Saudi Arabia
[3] King Saud Univ, King Abdullah Inst Nanotechnol, Riyadh 11451, Saudi Arabia
[4] Cent Met Res & Dev Inst CMRDI, Nanomat & Nanotechnol Dept, PO 87, Cairo 11421, Egypt
[5] Najran Univ, Fac Sci & Arts Sharurah, Dept Chem, Najran, Saudi Arabia
[6] Najran Univ, Fac Sci & Arts, Dept Phys, Najran, Saudi Arabia
[7] Mawlana Bhashani Sci & Technol Univ, Fac Sci, Dept Chem, Santosh 1902, Tangail, Bangladesh
关键词
AuNPs; PSi; H2O2; sensor; Linear sweep voltammetry; Square wave voltammetry; Sensitivity; GLASSY-CARBON ELECTRODE; REDUCED GRAPHENE OXIDE; ORGANIC VAPOR SENSOR; ELECTROCHEMICAL DETECTION; SILVER NANOPARTICLES; MESOPOROUS SILICON; OPTICAL BIOSENSOR; QUANTUM DOTS; N-TYPE; H2O2;
D O I
10.1016/j.ab.2020.114065
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A voltammetric approach was developed for the selective and sensitive determination of hydrogen peroxide using Au plated porous silicon (PSi) nanopowder modified glassy carbon electrode (GCE). The AuNPs-PSi hybrid structure was synthesized via stain etching procedure followed by an immersion plating method to deposit AuNPs onto PSi via a simple galvanic displacement reaction with no external reducing agent to convert Au3+ to Au-0. The as-fabricated AuNPs-PSi catalyst was successfully characterized by XRD, Raman, FTIR, XPS, SEM, TEM and EDS techniques. Well crystalline nature of the as-fabricated hybrid structure with AuNPs size ranging from 5 to 40 nm was observed. The specific surface area and total pore volume for both PSi and AuNPs plated PSi were evaluated using N-2 adsorption isotherm technique. Cyclic voltammetry and electrochemical impedance spectroscopy techniques were applied to investigate the catalytic efficiency of AuNPs-PSi modified electrode compared to pure PSi/GCE and unmodified GCE. The sensing performance of the active material modified GCE was thoroughly examined with linear sweep voltammetry (LSV) and square wave voltammetry (SWV) techniques. The AuNPs-PSi/GCE exhibited a remarkable linear dynamic range between 2.0 and 13.81 mM (for LSV) and 0.5-6.91 mM for (SWV) with high sensitivity and low detection limit of 10.65 mu AmM(-1)cm(2) and 14.84 mu M for LSV, whereas 10.41 mu AmM(-1)cm(2) and 15.16 mu M using SWV techniques, respectively. The fabricated sensor electrode showed excellent anti-interfering ability in the presence of several common biomolecules as well as demonstrated good operational stability and reproducibility with low relative standard deviation. Moreover, the modified electrode showed acceptable recovery of H2O2 in a real sample analysis. Thus, the developed AuNPs-PSi hybrid nanomaterial represents an excellent electrocatalyst for the efficient detection and quantification of H2O2 by the electrochemical approach.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Programmable Laser Patterning of Ag Nanoparticles and Reduced Graphene Oxide Hybrid Electrodes for Nonenzymatic Hydrogen Peroxide Detection
    Zhu, Lin
    Gao, Yuan-Yuan
    Han, Bing
    Liu, Sen
    Fu, Xiu-yan
    Ding, Hong
    Zhang, Yong-Lai
    ACS APPLIED NANO MATERIALS, 2019, 2 (12) : 7989 - 7996
  • [32] Pd nanoparticle-modified electrodes for nonenzymatic hydrogen peroxide detection
    Jue Wang
    Xue-jiao Chen
    Kai-ming Liao
    Guang-hou Wang
    Min Han
    Nanoscale Research Letters, 2015, 10
  • [33] A novel nonenzymatic hydrogen peroxide sensor based on Pd nanoparticles modified electrode
    Zhuang, Zhenjing
    MATERIALS AND COMPUTATIONAL MECHANICS, PTS 1-3, 2012, 117-119 : 790 - 794
  • [34] Electrospun carbon nanofibers with manganese dioxide nanoparticles for nonenzymatic hydrogen peroxide sensing
    Xiao, Xianping
    Song, Yonghai
    Liu, Hongyu
    Xie, Mingyun
    Hou, Haoqing
    Wang, Li
    Li, Zhuang
    JOURNAL OF MATERIALS SCIENCE, 2013, 48 (14) : 4843 - 4850
  • [35] Electrospun carbon nanofibers with manganese dioxide nanoparticles for nonenzymatic hydrogen peroxide sensing
    Xianping Xiao
    Yonghai Song
    Hongyu Liu
    Mingyun Xie
    Haoqing Hou
    Li Wang
    Zhuang Li
    Journal of Materials Science, 2013, 48 : 4843 - 4850
  • [36] Mediatorless Impedance Studies with Titanium Dioxide Conjugated Gold Nanoparticles for Hydrogen Peroxide Detection
    Halim, Nur Hamidah Abdul
    Lee, Yook Heng
    Marugan, Radha Swathe Priya Malon
    Hashim, Uda
    BIOSENSORS-BASEL, 2017, 7 (03):
  • [37] The Hydroxyl Radical is a Critical Intermediate in the Voltammetric Detection of Hydrogen Peroxide
    Roberts, James G.
    Voinov, Maxim A.
    Schmidt, Andreas C.
    Smirnova, Tatyana I.
    Sombers, Leslie A.
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2016, 138 (08) : 2516 - 2519
  • [38] Gold nanoparticles for sensitive detection of hydrogen peroxide: a simple non-enzymatic approach
    J. Sophia
    G. Muralidharan
    Journal of Applied Electrochemistry, 2015, 45 : 963 - 971
  • [39] Gold nanoparticles for sensitive detection of hydrogen peroxide: a simple non-enzymatic approach
    Sophia, J.
    Muralidharan, G.
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2015, 45 (09) : 963 - 971
  • [40] A colorimetric sensor for the detection of hydrogen peroxide using DNA-modified gold nanoparticles
    Lin, Wen-Zhi
    Yeung, Chun-Yan
    Liang, Chih-Kai
    Huang, Yi-Huei
    Liu, Cheng-Che
    Hou, Shao-Yi
    JOURNAL OF THE TAIWAN INSTITUTE OF CHEMICAL ENGINEERS, 2018, 89 : 49 - 55