Gold nanoparticles plated porous silicon nanopowder for nonenzymatic voltammetric detection of hydrogen peroxide

被引:20
|
作者
Rashed, Md. A. [1 ,7 ]
Harraz, Farid A. [1 ,4 ]
Faisal, M. [1 ,2 ]
El-Toni, Ahmed Mohamed [3 ]
Alsaiari, Mabkhoot [1 ,5 ]
Al-Assiri, M. S. [1 ,6 ]
机构
[1] Najran Univ, Adv Mat & Nanores Ctr, Promising Ctr Sensors & Elect Devices PCSED, POB 1988, Najran 11001, Saudi Arabia
[2] Najran Univ, Fac Sci & Arts, Dept Chem, Najran, Saudi Arabia
[3] King Saud Univ, King Abdullah Inst Nanotechnol, Riyadh 11451, Saudi Arabia
[4] Cent Met Res & Dev Inst CMRDI, Nanomat & Nanotechnol Dept, PO 87, Cairo 11421, Egypt
[5] Najran Univ, Fac Sci & Arts Sharurah, Dept Chem, Najran, Saudi Arabia
[6] Najran Univ, Fac Sci & Arts, Dept Phys, Najran, Saudi Arabia
[7] Mawlana Bhashani Sci & Technol Univ, Fac Sci, Dept Chem, Santosh 1902, Tangail, Bangladesh
关键词
AuNPs; PSi; H2O2; sensor; Linear sweep voltammetry; Square wave voltammetry; Sensitivity; GLASSY-CARBON ELECTRODE; REDUCED GRAPHENE OXIDE; ORGANIC VAPOR SENSOR; ELECTROCHEMICAL DETECTION; SILVER NANOPARTICLES; MESOPOROUS SILICON; OPTICAL BIOSENSOR; QUANTUM DOTS; N-TYPE; H2O2;
D O I
10.1016/j.ab.2020.114065
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A voltammetric approach was developed for the selective and sensitive determination of hydrogen peroxide using Au plated porous silicon (PSi) nanopowder modified glassy carbon electrode (GCE). The AuNPs-PSi hybrid structure was synthesized via stain etching procedure followed by an immersion plating method to deposit AuNPs onto PSi via a simple galvanic displacement reaction with no external reducing agent to convert Au3+ to Au-0. The as-fabricated AuNPs-PSi catalyst was successfully characterized by XRD, Raman, FTIR, XPS, SEM, TEM and EDS techniques. Well crystalline nature of the as-fabricated hybrid structure with AuNPs size ranging from 5 to 40 nm was observed. The specific surface area and total pore volume for both PSi and AuNPs plated PSi were evaluated using N-2 adsorption isotherm technique. Cyclic voltammetry and electrochemical impedance spectroscopy techniques were applied to investigate the catalytic efficiency of AuNPs-PSi modified electrode compared to pure PSi/GCE and unmodified GCE. The sensing performance of the active material modified GCE was thoroughly examined with linear sweep voltammetry (LSV) and square wave voltammetry (SWV) techniques. The AuNPs-PSi/GCE exhibited a remarkable linear dynamic range between 2.0 and 13.81 mM (for LSV) and 0.5-6.91 mM for (SWV) with high sensitivity and low detection limit of 10.65 mu AmM(-1)cm(2) and 14.84 mu M for LSV, whereas 10.41 mu AmM(-1)cm(2) and 15.16 mu M using SWV techniques, respectively. The fabricated sensor electrode showed excellent anti-interfering ability in the presence of several common biomolecules as well as demonstrated good operational stability and reproducibility with low relative standard deviation. Moreover, the modified electrode showed acceptable recovery of H2O2 in a real sample analysis. Thus, the developed AuNPs-PSi hybrid nanomaterial represents an excellent electrocatalyst for the efficient detection and quantification of H2O2 by the electrochemical approach.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] A visual detection of hydrogen peroxide on the basis of Fenton reaction with gold nanoparticles
    Sang, You
    Zhang, Li
    Li, Yuan Fang
    Chen, Li Qiang
    Xu, Jia Li
    Huang, Cheng Zhi
    ANALYTICA CHIMICA ACTA, 2010, 659 (1-2) : 224 - 228
  • [22] Electrospun porous CuFe2O4 nanotubes on nickel foam for nonenzymatic voltammetric determination of glucose and hydrogen peroxide
    Xia, Haiyan
    Li, Jianan
    Ma, Lei
    Liu, Qingfang
    Wang, Jianbo
    JOURNAL OF ALLOYS AND COMPOUNDS, 2018, 739 : 764 - 770
  • [23] Enzymeless electrochemical detection of hydrogen peroxide at Pd nanoparticles/porous graphene
    Xue, Wanyi
    Bo, Xiangjie
    Zhou, Ming
    Guo, Liping
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 781 : 204 - 211
  • [24] Silver Nanoparticle Impregnated Porous Carbon as a Nonenzymatic Hydrogen Peroxide Sensor
    Zou, Yi-Song
    Jia, Miao-Miao
    Fan, Jun-Qin
    Qin, Fa-Mei
    Yu, Jian-Guo
    Zhao, Yong-Nan
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (07): : 5781 - 5791
  • [25] Structure engineering of silicon nanoparticles with dual signals for hydrogen peroxide detection
    Liu, Huiqiao
    He, Yanan
    Mu, Jiping
    Cao, Kangzhe
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2022, 266
  • [26] Cuprous Oxide Cubebox for Nonenzymatic Amperometric Hydrogen Peroxide Detection
    Chen, Delun
    Cao, Yang
    Chen, Yong
    Huang, Wei
    Li, Changjiu
    Wang, Xiaohong
    Zhang, Kexi
    Tu, Jinchun
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON MATERIALS, ENVIRONMENTAL AND BIOLOGICAL ENGINEERING, 2015, 10 : 93 - 96
  • [27] Sensitive nonenzymatic detection of hydrogen peroxide at nitrogen-doped graphene supported-CoFe nanoparticles
    Hassan, Mehboob
    Jiang, Yue
    Bo, Xiangjie
    Zhou, Ming
    TALANTA, 2018, 188 : 339 - 348
  • [28] Voltammetric Detection of Hydrogen Peroxide at Carbon Fiber Microelectrodes
    Sanford, Audrey L.
    Morton, Stephen W.
    Whitehouse, Kelsey L.
    Oara, Hannah M.
    Lugo-Morales, Leyda Z.
    Roberts, James G.
    Sombers, Leslie A.
    ANALYTICAL CHEMISTRY, 2010, 82 (12) : 5205 - 5210
  • [29] Pd nanoparticle-modified electrodes for nonenzymatic hydrogen peroxide detection
    Wang, Jue
    Chen, Xue-jiao
    Liao, Kai-ming
    Wang, Guang-hou
    Han, Min
    NANOSCALE RESEARCH LETTERS, 2015, 10
  • [30] Nonenzymatic Electrochemical Sensor Based on PdAu Nanoflowers for the Detection of Hydrogen Peroxide
    Hu, Xia
    Shen, Guangyu
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (05): : 4057 - 4065