Sensitivity of T2-weighted FSE sequences towards physiological iron depositions in normal brains at 1.5 and 3.0 T

被引:22
|
作者
Allkemper, T [1 ]
Schwindt, W [1 ]
Maintz, D [1 ]
Heindel, W [1 ]
Tombach, B [1 ]
机构
[1] Univ Munster, Dept Clin Radiol, D-48149 Munster, Germany
关键词
magnetic resonance imaging; brain; Parkinsonian disorders; susceptibility effect; field strength;
D O I
10.1007/s00330-004-2241-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate the sensitivity of T2-weighted fast spin-echo (FSE) sequences to physiological iron depositions in normal brains at MR imaging field strengths of 1.5 and 3.0 T. T2-weighted FSE sequences acquired at 1.5 and 3.0 T clinical imaging systems (Gyroscan Intera, Philips Medical Systems, Best, The Netherlands) were compared by means of MRI in phantoms (n=6) and healthy volunteers (n=10). Contrast-to-noise ratios (CNRs) of tubes doped with iron oxides at different concentrations and of brain areas with physiological iron depositions (nucleus ruber, substantia nigra, globus pallidus) were calculated for either field strength. Apparent susceptibility effects of iron-containing brain structures were qualitatively analyzed by comparing the degree of visible hypointensity by a score system at either field strength. The mean CNR of iron oxide tubes and iron-containing brain areas was significantly decreased at 3.0 T. Qualitative analysis confirmed these measurements. Detection and diagnosis of brain disorders with altered iron content such as neurodegenerative parkinsonian disorders (NPD) or intracerebral hemorrhage should benefit from the increased sensitivity of T2-weighted FSE sequences to susceptibility effects at 3.0 T.
引用
收藏
页码:1000 / 1004
页数:5
相关论文
共 50 条
  • [21] MRI ASSESSMENT OF PARATHYROID ADENOMA - THE VALUE OF T2-WEIGHTED SEQUENCES
    BRULE, JM
    DEGEORGES, A
    MAUSS, Y
    JOST, JB
    WENGER, JJ
    LEBRAS, Y
    SCHEIBER, C
    MARESCAUX, J
    CHAMBRON, J
    ANNALES DE RADIOLOGIE, 1989, 32 (06) : 457 - 466
  • [22] MRI ASSESSMENT OF PARATHYROID ADENOMA - THE VALUE OF T2-WEIGHTED SEQUENCES
    BRULE, JM
    DEGEORGES, A
    MAUSS, Y
    JOST, JB
    WENGER, JJ
    LEBRAS, Y
    SCHEIBER, C
    MARESCAUX, J
    CHAMBRON, J
    SEMAINE DES HOPITAUX, 1990, 66 (25): : 1513 - 1522
  • [23] High signals in the uterine cervix on T2-weighted MRI sequences
    De M. Graef
    R. Karam
    V. Juhan
    P. Daclin
    A. Maubon
    J. Rouanet
    European Radiology, 2003, 13 : 118 - 126
  • [24] High signals in the uterine cervix on T2-weighted MRI sequences
    De Graef, M
    Karam, R
    Juhan, V
    Daclin, PY
    Maubon, AJ
    Rouanet, JP
    EUROPEAN RADIOLOGY, 2003, 13 (01) : 118 - 126
  • [25] T2-weighted MRI of the Upper Abdomen: Comparison of Four Fat-Suppressed T2-weighted Sequences Including PROPELLER (BLADE) Technique
    Bayramoglu, Sibel
    Kilickesmez, Oezguer
    Cimilli, Tan
    Kayhan, Arda
    Yirik, Guelseren
    Islim, Filiz
    Alibek, Sedat
    ACADEMIC RADIOLOGY, 2010, 17 (03) : 368 - 374
  • [26] Comparison of T2-Weighted 3D-Space and T2-Weighted 2D-TSE Sequences in Lumbar Spine MR Imaging
    Qurat-ul-Ain
    Nadeem, Syed Farrukh
    Mirza, Tariq Mahmood
    Shafiq, Mazhar
    Batool, Zahida
    Khadijah-tul-Kubra
    ANNALS OF KING EDWARD MEDICAL UNIVERSITY LAHORE PAKISTAN, 2023, 29 (04): : 361 - 366
  • [27] Efficacy of contrast medium use for neuroimaging at 3.0 T - Utility of IR-FSE compared to other T1-weighted pulse sequences
    Fischbach, F
    Bruhn, H
    Pech, M
    Neumann, F
    Ricke, J
    Felix, R
    Hofmann, KT
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2005, 29 (04) : 499 - 505
  • [28] T1-and T2-weighted MRI signal and histology findings in suboptimally fixed human brains
    Frigon, Eve-Marie
    Pharand, Philippe
    Gerin-Lajoie, Amy
    Sanches, Liana Guerra
    Boire, Denis
    Dadar, Mahsa
    Maranzano, Josefina
    JOURNAL OF NEUROSCIENCE METHODS, 2024, 412
  • [29] Abdominal T2-weighted imaging by free-breath PACE with a 3.0T MRI system
    Moroi, T.
    Mizuuchi, N.
    Maruyama, K.
    Imura, C.
    Isobe, I.
    Usagawa, T.
    Iriguchi, N.
    2007 IEEE/ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING, VOLS 1-4, 2007, : 740 - 743
  • [30] Magnetic resonance imaging of hyaline cartilage defects at 1.5T and 3.0T:: comparison of medium T2-weighted fast spin echo, T1-weighted two-dimensional and three-dimensional gradient echo pulse sequences
    Fischbach, F
    Bruhn, H
    Unterhauser, F
    Ricke, J
    Wieners, G
    Felix, R
    Weiler, A
    Schröder, RJ
    ACTA RADIOLOGICA, 2005, 46 (01) : 67 - 73