Efficacy of contrast medium use for neuroimaging at 3.0 T - Utility of IR-FSE compared to other T1-weighted pulse sequences

被引:16
|
作者
Fischbach, F [1 ]
Bruhn, H [1 ]
Pech, M [1 ]
Neumann, F [1 ]
Ricke, J [1 ]
Felix, R [1 ]
Hofmann, KT [1 ]
机构
[1] Humboldt Univ, Sch Med, Dept Radiol Charite, D-13353 Berlin, Germany
关键词
magnetic resonance imaging; ultra-high field; contrast media; blood-brain barrier disruption;
D O I
10.1097/01.rct.0000166636.85918.3d
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
As inversion-recovery (IR) technique improves T1 contrast at high field strength, signal enhancement by T1-shortening contrast media may be affected. To clarify the different enhancement properties at 3.0 T, the authors compared T1-weighted sequences. Twelve contrast-enhancing lesions were investigated by spin-echo (SE), inversion recovery fast spin-echo (IR-FSE), two-dimensional gradient-echo (2D GE), and magnetization-prepared three-dimensional gradient-echo (3D GE) sequences and evaluated by comparing signal-intensity enhancements within the lesions. In addition, signal-to-noise-ratios (SNR) and contrast-to-noise-ratios (CNR) were measured. On average, signal enhancement of the lesions amounted to 60% for SE, 57% for IR-FSE, 32% for 2D GE, and 35% for 3D GE images. CNR of gray matter versus white matter was significantly higher for IR SE and GE imaging than for genuine SE and 2D GE acquisitions (Wilcoxon test), while 2D GE imaging alone had an excellent SNR. As IR-FSE images provide an excellent CNR for gray and white matter in the brain and contrast enhancement performs almost similarly well compared with SE imaging, this technique appears to be well suited for T1-weighted neuroimaging without and with contrast enhancement at 3.0 T. However, the inherent blurring of the IR-FSE can lead to poor performance for very small lesions.
引用
收藏
页码:499 / 505
页数:7
相关论文
共 50 条
  • [1] MRI OF LIVER METASTASES - T1-WEIGHTED PULSE SEQUENCES
    STARK, DD
    WITTENBERG, J
    FERRUCCI, JT
    GASTROINTESTINAL RADIOLOGY, 1986, 11 (03): : 295 - 295
  • [2] Evaluation of fat saturation and contrast enhancement on T1-weighted FLAIR sequence of the spine at 3.0 T
    Lavdas, Eleftherios
    Tsougos, Ioannis
    Arikidis, Nikos
    Roka, Violetta
    Fezoulidis, Ioannis V.
    Vlychou, Marianna
    CLINICAL IMAGING, 2014, 38 (04) : 428 - 433
  • [3] Evaluation of jugular foramen nerves by using b-FFE, T2-weighted DRIVE, T2-weighted FSE and post-contrast T1-weighted MRI sequences
    Aydin, Hasan
    Altin, Elif
    Dilli, Alper
    Sipahioglu, Serdar
    Hekimoglu, Baki
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2011, 17 (01) : 3 - 9
  • [4] Comparison of contrast-enhanced T1-weighted FLAIR with BLADE, and spin-echo T1-weighted sequences in intracranial MRI
    Alkan, Oezlem
    Kizilkilic, Osman
    Yildirim, Tuelin
    Alibek, Sedat
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2009, 15 (02): : 75 - 80
  • [5] Novel application of T1-weighted BLADE sequences with fat suppression compared to TSE in contrast-enhanced T1-weighted imaging of the neck: Cutting-edge images?
    Finkenzeller, Thomas
    Zorger, Niels
    Kuehnel, Thomas
    Paetzel, Christian
    Schuierer, Gerhard
    Stroszczynski, Christian
    Fellner, Claudia
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (03) : 660 - 668
  • [6] RENAL CORTICOMEDULLARY JUNCTION - PERFORMANCE OF T1-WEIGHTED MR PULSE SEQUENCES
    BAUMGARTNER, BR
    NELSON, RC
    TORRES, WE
    MALKO, JA
    PETERSON, JE
    BERNARDINO, ME
    INVESTIGATIVE RADIOLOGY, 1989, 24 (11) : 884 - 887
  • [7] Comparison of T1-weighted Spin-Echo and 3D T1-weighted multishot echo planar pulse sequences in imaging the brain at 1T
    Karantanas, AH
    Papanikolaou, N
    Vasiou, K
    Lavdas, E
    MAGNETIC RESONANCE IMAGING, 1999, 17 (05) : 663 - 668
  • [8] Abdominal MRI at 3.0 T: LAVA-Flex Compared With Conventional Fat Suppression T1-Weighted Images
    Li, Xing Hui
    Zhu, Jiang
    Zhang, Xiao Ming
    Ji, Yi Fan
    Chen, Tian Wu
    Huang, Xiao Hua
    Yang, Lin
    Zeng, Nan Lin
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 40 (01) : 58 - 66
  • [9] Improved contrast for myeloma focal lesions with T2-weighted Dixon images compared to T1-weighted images
    Danner, A.
    Brumpt, E.
    Alilet, M.
    Tio, G.
    Omoumi, P.
    Aubry, S.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2019, 100 (09) : 513 - 519
  • [10] Contrast behavior of high-spatial-resolution T1-weighted MR imaging at 3.0 T vs. 1.5 T
    Isoda, Hiroyoshi
    Arizono, Shigeki
    Shimada, Kotaro
    Hirokawa, Yuusuke
    Maetani, Yoji S.
    Kataoka, Masako
    Nakamoto, Yuji
    Shibata, Toshiya
    Togashi, Kaori
    CLINICAL IMAGING, 2011, 35 (02) : 133 - 138