Efficacy of contrast medium use for neuroimaging at 3.0 T - Utility of IR-FSE compared to other T1-weighted pulse sequences

被引:16
|
作者
Fischbach, F [1 ]
Bruhn, H [1 ]
Pech, M [1 ]
Neumann, F [1 ]
Ricke, J [1 ]
Felix, R [1 ]
Hofmann, KT [1 ]
机构
[1] Humboldt Univ, Sch Med, Dept Radiol Charite, D-13353 Berlin, Germany
关键词
magnetic resonance imaging; ultra-high field; contrast media; blood-brain barrier disruption;
D O I
10.1097/01.rct.0000166636.85918.3d
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
As inversion-recovery (IR) technique improves T1 contrast at high field strength, signal enhancement by T1-shortening contrast media may be affected. To clarify the different enhancement properties at 3.0 T, the authors compared T1-weighted sequences. Twelve contrast-enhancing lesions were investigated by spin-echo (SE), inversion recovery fast spin-echo (IR-FSE), two-dimensional gradient-echo (2D GE), and magnetization-prepared three-dimensional gradient-echo (3D GE) sequences and evaluated by comparing signal-intensity enhancements within the lesions. In addition, signal-to-noise-ratios (SNR) and contrast-to-noise-ratios (CNR) were measured. On average, signal enhancement of the lesions amounted to 60% for SE, 57% for IR-FSE, 32% for 2D GE, and 35% for 3D GE images. CNR of gray matter versus white matter was significantly higher for IR SE and GE imaging than for genuine SE and 2D GE acquisitions (Wilcoxon test), while 2D GE imaging alone had an excellent SNR. As IR-FSE images provide an excellent CNR for gray and white matter in the brain and contrast enhancement performs almost similarly well compared with SE imaging, this technique appears to be well suited for T1-weighted neuroimaging without and with contrast enhancement at 3.0 T. However, the inherent blurring of the IR-FSE can lead to poor performance for very small lesions.
引用
收藏
页码:499 / 505
页数:7
相关论文
共 50 条
  • [21] Magnetic resonance imaging of hyaline cartilage defects at 1.5T and 3.0T:: comparison of medium T2-weighted fast spin echo, T1-weighted two-dimensional and three-dimensional gradient echo pulse sequences
    Fischbach, F
    Bruhn, H
    Unterhauser, F
    Ricke, J
    Wieners, G
    Felix, R
    Weiler, A
    Schröder, RJ
    ACTA RADIOLOGICA, 2005, 46 (01) : 67 - 73
  • [22] A comparative study of FLAIR and contrast enhanced T1-weighted imaging: Utility and reproducibility in the evaluation of neurocysticercosis
    Boaz, TL
    Ressler, JA
    Go, JL
    Zee, C
    RADIOLOGY, 1999, 213P : 483 - 483
  • [23] Editorial Comment: Contrast-Enhanced T1-Weighted Sequences in MR Enterography-Faster Is Better
    Fraum, Tyler J.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 218 (04) : 686 - 686
  • [24] Contrast enhanced IR-SSFP examination compared with T1-weighted turbo spin-echo imaging of cardiac tumors and tumorlike lesions
    Bauner, K. U.
    Sandner, T.
    Notohamiprodjo, M.
    Schmoeckel, M.
    Reiser, M. F.
    Huber, A. M.
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 78 (01) : 93 - 98
  • [25] Contrast-Enhanced 3D Spin Echo T1-Weighted Sequence Outperforms 3D Gradient Echo T1-Weighted Sequence for the Detection of Multiple Sclerosis Lesions on 3.0 T Brain MRI
    de Panafieu, Ariane
    Lecler, Augustin
    Goujon, Adrien
    Krystal, Sidney
    Gueguen, Antoine
    Sadik, Jean-Claude
    Savatovsky, Julien
    Duron, Loic
    INVESTIGATIVE RADIOLOGY, 2023, 58 (05) : 314 - 319
  • [26] MR imaging of the knee: Improvement of signal and contrast efficiency of T1-weighted turbo spin echo sequences by applying a driven equilibrium (DRIVE) pulse
    Radlbauer, Rudolf
    Lomoschitz, Friedrich
    Salomonowitz, Erich
    Eberhardt, Knut E.
    Stadlbauer, Andreas
    EUROPEAN JOURNAL OF RADIOLOGY, 2010, 75 (02) : E82 - E87
  • [27] MR IMAGING OF LIVER METASTASES AT 1.5 T - SIMILAR CONTRAST DISCRIMINATION WITH T1-AND T2-WEIGHTED PULSE SEQUENCES
    SAINI, S
    LI, W
    WALLNER, B
    HAHN, PF
    EDELMAN, RR
    RADIOLOGY, 1991, 181 (02) : 449 - 453
  • [28] Post-contrast T1-weighted sequences in pediatric abdominal imaging: comparative analysis of three different sequences and imaging approach
    Roque, Andreia
    Ramalho, Miguel
    AlObaidy, Mamdoh
    Heredia, Vasco
    Burke, Lauren M.
    de Campos, Rafael O. P.
    Semelka, Richard C.
    PEDIATRIC RADIOLOGY, 2014, 44 (10) : 1258 - 1265
  • [29] Is there an Added Value of T1-Weighted Contrast-Enhanced Fat-suppressed Spin-Echo MR Sequences Compared to STIR Sequences in MRI of the Foot and Ankle?
    Zubler, Veronika
    Zanetti, Marco
    Dietrich, Tobias J.
    Espinosa, Norman
    Pfirrmann, Christian W.
    Mamisch-Saupe, Nadja
    EUROPEAN RADIOLOGY, 2017, 27 (08) : 3452 - 3459
  • [30] Is there an Added Value of T1-Weighted Contrast-Enhanced Fat-suppressed Spin-Echo MR Sequences Compared to STIR Sequences in MRI of the Foot and Ankle?
    Veronika Zubler
    Marco Zanetti
    Tobias J. Dietrich
    Norman Espinosa
    Christian W. Pfirrmann
    Nadja Mamisch-Saupe
    European Radiology, 2017, 27 : 3452 - 3459