Efficacy of contrast medium use for neuroimaging at 3.0 T - Utility of IR-FSE compared to other T1-weighted pulse sequences

被引:16
|
作者
Fischbach, F [1 ]
Bruhn, H [1 ]
Pech, M [1 ]
Neumann, F [1 ]
Ricke, J [1 ]
Felix, R [1 ]
Hofmann, KT [1 ]
机构
[1] Humboldt Univ, Sch Med, Dept Radiol Charite, D-13353 Berlin, Germany
关键词
magnetic resonance imaging; ultra-high field; contrast media; blood-brain barrier disruption;
D O I
10.1097/01.rct.0000166636.85918.3d
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
As inversion-recovery (IR) technique improves T1 contrast at high field strength, signal enhancement by T1-shortening contrast media may be affected. To clarify the different enhancement properties at 3.0 T, the authors compared T1-weighted sequences. Twelve contrast-enhancing lesions were investigated by spin-echo (SE), inversion recovery fast spin-echo (IR-FSE), two-dimensional gradient-echo (2D GE), and magnetization-prepared three-dimensional gradient-echo (3D GE) sequences and evaluated by comparing signal-intensity enhancements within the lesions. In addition, signal-to-noise-ratios (SNR) and contrast-to-noise-ratios (CNR) were measured. On average, signal enhancement of the lesions amounted to 60% for SE, 57% for IR-FSE, 32% for 2D GE, and 35% for 3D GE images. CNR of gray matter versus white matter was significantly higher for IR SE and GE imaging than for genuine SE and 2D GE acquisitions (Wilcoxon test), while 2D GE imaging alone had an excellent SNR. As IR-FSE images provide an excellent CNR for gray and white matter in the brain and contrast enhancement performs almost similarly well compared with SE imaging, this technique appears to be well suited for T1-weighted neuroimaging without and with contrast enhancement at 3.0 T. However, the inherent blurring of the IR-FSE can lead to poor performance for very small lesions.
引用
收藏
页码:499 / 505
页数:7
相关论文
共 50 条
  • [31] Post-contrast T1-weighted sequences in pediatric abdominal imaging: comparative analysis of three different sequences and imaging approach
    Andreia Roque
    Miguel Ramalho
    Mamdoh AlObaidy
    Vasco Herédia
    Lauren M. Burke
    Rafael O. P. de Campos
    Richard C. Semelka
    Pediatric Radiology, 2014, 44 : 1258 - 1265
  • [32] Combined Use of T2-Weighted MRI and T1-Weighted Dynamic Contrast-Enhanced MRI in the Automated Analysis of Breast Lesions
    Bhooshan, Neha
    Giger, Maryellen
    Lan, Li
    Li, Hui
    Marquez, Angelica
    Shimauchi, Akiko
    Newstead, Gillian M.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (02) : 555 - 563
  • [33] T1-weighted Fluid Attenuated Inversion Recovery (FLAIR) pulse sequences: Use and limitations in magnetic resonance brain and spinal cord studies
    Aprile, I
    Muti, M
    Bartolini, N
    Zenoni, A
    Tazza, G
    Principi, M
    Italiani, M
    Ottaviano, P
    RIVISTA DI NEURORADIOLOGIA, 2001, 14 (03): : 301 - 308
  • [34] MnDPDP as a negative hepatic contrast agent: Evaluation of STIR imaging compared with T1-weighted SE and GE techniques
    Halavaara, JT
    Lamminen, AE
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (01) : 94 - 99
  • [35] MnDPDP as a negative hepatic contrast agent: Evaluation of STIR imaging compared with T1-weighted SE and GE techniques
    Department of Radiology, Helsinki University Central Hospital, Haartmaninkatu 4, 02900 Helsinki, Finland
    不详
    J. COMPUT. ASSISTED TOMOGR., 1 (94-99):
  • [36] Magnetic resonance imaging of hyaline cartilage defects at 1.5T and 3.0T: Comparison of medium T2-weighted fast spin echo, T1-weighted two-dimensional and three-dimensional gradient echo pulse sequences (vol 46, pg 67, 2005)
    Fischbach, F
    Bruhn, H
    Unterhauser, F
    Ricke, J
    Wieners, G
    Felix, R
    Weiler, A
    Schroder, RJ
    ACTA RADIOLOGICA, 2005, 46 (02) : 218 - 218
  • [37] Effects of Contrast Agent Concentration on the Signal Intensity and Turbo Factor of TSE and Slice-selective IR in T1-weighted Contrast Imaging
    Han, Yong Soo
    Lee, Soo Chul
    Lee, Dong Yong
    Choi, Jiwon
    Lee, Jong Woong
    Kweon, Dae Cheol
    JOURNAL OF MAGNETICS, 2016, 21 (01) : 115 - 124
  • [38] Utility Decay Rates of T1-Weighted Magnetic Resonance Imaging Contrast Based on Redox-Sensitive Paramagnetic Nitroxyl Contrast Agents
    Matsumoto, Ken-ichiro
    BIOLOGICAL & PHARMACEUTICAL BULLETIN, 2009, 32 (04) : 711 - 716
  • [39] MR imaging in patents with Crohn disease: Value of T2-versus T1-weighted gadolinium-enhanced MR sequences with use of an oral superparamagnetic contrast agent
    Maccioni, F
    Bruni, A
    Viscido, A
    Colaiacomo, MC
    Cocco, A
    Montesani, C
    Caprilli, R
    Marini, M
    RADIOLOGY, 2006, 238 (02) : 517 - 530
  • [40] Comparison of inversion recovery and contrast-enhanced T1-weighted fat-suppressed sequences for the staging of cervical lymphoma
    Freund, Wolfgang
    Seifarth, Armin
    Stuber, Gregor
    Cario, Holger
    Puig, Stefan
    Aschoff, Andrik J.
    CLINICAL IMAGING, 2012, 36 (05) : 568 - 573