Validation of the 3M™ Petrifilm™ Coliform Count Plate for Enumeration of Coliforms in Bottled Water: AOAC Performance Tested MethodSM 082101

被引:3
|
作者
Schumacher, April J. [1 ]
Lingle, Cari K. [1 ]
Silbernagel, Karen M. [1 ]
Thompson-Strehlow, Leslie [2 ]
机构
[1] 3M Co, Food Safety Dept 3M, Bldg 260-6B-01, St Paul, MN 55144 USA
[2] SGS Vanguard Sci, Res & Dev, 224 North Derby Lane, North Sioux City, SD 57049 USA
关键词
Metadata - Software testing;
D O I
10.1093/jaoacint/qsab137
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: The 3M (TM) Petrifilm (TM) Coliform Count (CC) Plate is a sample-ready-culture medium system which contains modified Violet Red Bile nutrients, a cold-water-soluble gelling agent, and a tetrazolium indicator that facilitates colony enumeration. Objective: To validate the 3M Petrifilm CC Plate method for bottled water through the AOAC (R) Performance Tested Method(s)(SM) program. Methods: The performance of the 3M Petrifilm CC Plate was compared to the U.S. Food and Drug Administration Bacteriological Analytical Manual Chapter 4, Section III.D for the enumeration of coliforms in bottled water. Matrix data were normalized by log(10) transformation and performance indicators included repeatability and difference of means with 90 and 95% confidence intervals. Inclusivity, exclusivity, robustness, and product consistency and stability were evaluated. Results: This study demonstrated that the 3M Petrifilm CC Plate method detects and enumerates coliforms from bottled water. The average log10 counts of the 3M Petrifilm CC Plate method were equivalent to or better than the average log(10) counts of the reference method. Results from inclusivity and exclusivity studies demonstrated that the 3M Petrifilm CC Plate method differentiated coliforms from non-coliform strains. In product consistency, stability, and robustness testing, different lots of 3M Petrifilm CC Plates and small deviations in incubation time and temperature did not affect test results. Conclusion: The 3M Petrifilm CC Plate method is an accurate and robust method for the enumeration of coliforms in bottled water.
引用
收藏
页码:866 / 875
页数:10
相关论文
共 50 条
  • [1] 3M™ Petrifilm Yeast and Mold Count Plate for the Enumeration of Yeasts and Molds in Dried Cannabis Flower: AOAC Official MethodSM 997.02
    Schumacher, April
    Lingle, Cari
    Silbernagel, Karen M.
    JOURNAL OF AOAC INTERNATIONAL, 2023, 106 (02) : 412 - 419
  • [2] 3M™ Petrifilm™ Rapid Aerobic Count (RAC) Plate Method for the Enumeration of Aerobic Bacteria on Selected Surfaces: AOAC Official MethodSM 2015.13
    Lingle, Cari K.
    Schumacher, April J.
    Rosauer, Micki L.
    Silbernagel, Karen M.
    Deterding, Andrew
    JOURNAL OF AOAC INTERNATIONAL, 2022, 106 (01) : 165 - 170
  • [3] 3M™ Petrifilm™ Rapid Yeast and Mold Count Plate for the Enumeration of Yeasts and Molds in Dried Cannabis Flower: AOAC Official MethodSM 2014.05
    Schumacher, April
    Lingle, Cari
    Silbernagel, Karen M.
    JOURNAL OF AOAC INTERNATIONAL, 2023, 106 (02) : 401 - 411
  • [4] Dry rehydratable film method for rapid enumeration of coliforms in foods (3M™ Petrifilm™ Rapid Coliform Count plate):: Collaborative study
    Kinneberg, KM
    Lindberg, KG
    JOURNAL OF AOAC INTERNATIONAL, 2002, 85 (01) : 56 - 71
  • [5] Validation of the AquaCHROM™ ECC for the Detection and Enumeration of Coliforms and Escherichia coli in Water Samples: AOAC Performance Tested MethodSM 072202
    Blackburn, Jonathan
    Deterding, Andrew
    Thompson, Wesley
    Benzinger Jr, M. Joseph
    Bastin, Benjamin
    Evrard, Julie
    Wentrup, Cecilia
    Michon, Christophe
    Ramos, Hugo Cruz
    JOURNAL OF AOAC INTERNATIONAL, 2023, 106 (03) : 678 - 689
  • [6] Evaluation of the 3M™ Petrifilm™ Rapid E. coli/Coliform Count Plate for the Enumeration of E. coli and Coliforms: Collaborative Study, First Action: 2018.13
    Bird, Patrick
    Bastin, Benjamin
    Klass, Nicole
    Crowley, Erin
    Agin, James
    Goins, David
    Bakken, Hannah
    Lingle, Cari
    Schumacher, April
    JOURNAL OF AOAC INTERNATIONAL, 2020, 103 (02) : 513 - 522
  • [7] Evaluation of the 3M petrifilm Enterobacteriaceae Count plate method for the enumeration of Enterobacteriaceae in foods
    Silbernagel, KM
    Lindberg, KG
    JOURNAL OF FOOD PROTECTION, 2002, 65 (09) : 1452 - 1456
  • [8] Validation of the 3M™ Environmental Scrub Sampler with Wide-Spectrum Neutralizer: AOAC Performance Tested MethodSM 022104
    Rosauer, Micki L.
    Silbernagel, Karen M.
    Thompson, Wesley
    JOURNAL OF AOAC INTERNATIONAL, 2022, 105 (03) : 876 - 888
  • [9] 3M™ Petrifilm™ Rapid Yeast and Mold Count Plate Method for the Enumeration of Yeast and Mold on Selected Surfaces: AOAC Official Method 2014.05
    Lingle, Cari K.
    Schumacher, April J.
    Rosauer, Micki L.
    Silbernagel, Karen M.
    Blackburn, Jonathan
    JOURNAL OF AOAC INTERNATIONAL, 2023, 106 (02) : 389 - 400
  • [10] Comparison of 3M petrifilm staph express count plates, and 3M petrifilm rapid coliform count plates with standard bacteriology of bovine milk
    Wallace, J. A.
    Roy, J. P.
    Bouchard, E.
    Descoteaux, L.
    Messier, S.
    Dutremblay, D.
    PROCEEDINGS OF THE FORTIETH ANNUAL CONFERENCE AMERICAN ASSOCIATION OF BOVINE PRACTITIONERS, 2007, : 268 - 268