Validation of the 3M™ Petrifilm™ Coliform Count Plate for Enumeration of Coliforms in Bottled Water: AOAC Performance Tested MethodSM 082101

被引:3
|
作者
Schumacher, April J. [1 ]
Lingle, Cari K. [1 ]
Silbernagel, Karen M. [1 ]
Thompson-Strehlow, Leslie [2 ]
机构
[1] 3M Co, Food Safety Dept 3M, Bldg 260-6B-01, St Paul, MN 55144 USA
[2] SGS Vanguard Sci, Res & Dev, 224 North Derby Lane, North Sioux City, SD 57049 USA
关键词
Metadata - Software testing;
D O I
10.1093/jaoacint/qsab137
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: The 3M (TM) Petrifilm (TM) Coliform Count (CC) Plate is a sample-ready-culture medium system which contains modified Violet Red Bile nutrients, a cold-water-soluble gelling agent, and a tetrazolium indicator that facilitates colony enumeration. Objective: To validate the 3M Petrifilm CC Plate method for bottled water through the AOAC (R) Performance Tested Method(s)(SM) program. Methods: The performance of the 3M Petrifilm CC Plate was compared to the U.S. Food and Drug Administration Bacteriological Analytical Manual Chapter 4, Section III.D for the enumeration of coliforms in bottled water. Matrix data were normalized by log(10) transformation and performance indicators included repeatability and difference of means with 90 and 95% confidence intervals. Inclusivity, exclusivity, robustness, and product consistency and stability were evaluated. Results: This study demonstrated that the 3M Petrifilm CC Plate method detects and enumerates coliforms from bottled water. The average log10 counts of the 3M Petrifilm CC Plate method were equivalent to or better than the average log(10) counts of the reference method. Results from inclusivity and exclusivity studies demonstrated that the 3M Petrifilm CC Plate method differentiated coliforms from non-coliform strains. In product consistency, stability, and robustness testing, different lots of 3M Petrifilm CC Plates and small deviations in incubation time and temperature did not affect test results. Conclusion: The 3M Petrifilm CC Plate method is an accurate and robust method for the enumeration of coliforms in bottled water.
引用
收藏
页码:866 / 875
页数:10
相关论文
共 50 条
  • [21] Evaluation of the 3M™ petrifilm™ rapid aerobic count plate for the enumeration of aerobic bacteria: Collaborative study, first action 2015.13
    Bird, Patrick
    Flannery, Jonathan
    Crowley, Erin
    Agin, James
    Goins, David
    Jechorek, Robert
    Journal of AOAC International, 2016, 99 (03): : 664 - 675
  • [22] 3M™ Petrifilm™ Staph Express Count plate method for the enumeration of Staphylococcus aureus in selected dairy foods:: Collaborative study
    Silbernagel, KM
    Jechorek, RP
    Carver, CN
    Horter, BL
    Lindberg, KG
    JOURNAL OF AOAC INTERNATIONAL, 2003, 86 (05) : 963 - 970
  • [23] Evaluation of the 3M™ Petrifilm™ Rapid Aerobic Count Plate for the Enumeration of Aerobic Bacteria: Collaborative Study, First Action 2015.13
    Bird, Patrick
    Flannery, Jonathan
    Crowley, Erin
    Agin, James
    Goins, David
    Jechorek, Robert
    JOURNAL OF AOAC INTERNATIONAL, 2016, 99 (03) : 664 - 675
  • [24] Validation of MICA Legionella for Enumeration of Legionella pneumophila in Sanitary Waters and Cooling Tower Waters: AOAC Performance Tested MethodSM 032201
    Passot, Fanny
    Peslier, Sabine
    Benzinger Jr, M. Joseph
    Blackburn, Jonathan
    Thompson, Wesley
    Bastin, Benjamin
    Dumont, Audrey
    Dukan, Sam
    JOURNAL OF AOAC INTERNATIONAL, 2023, 106 (03) : 725 - 736
  • [25] Validation of the revealVR 3-D for peanut lateral flow test: AOAC performance tested methodSM 111901
    Le Q.-N.
    Vance A.
    Bakir N.
    Almy D.
    Slenk E.
    Roman B.
    Klass N.
    Bastin B.
    Donofrio R.
    Journal of AOAC International, 2021, 103 (04) : 1112 - 1118
  • [26] Validation of the Reveal® 3-D for Peanut Lateral Flow Test: AOAC Performance Tested MethodSM 111901
    Quynh-Nhi Le
    Vance, Alexis
    Bakir, Nawal
    Almy, Dave
    Slenk, Emily
    Roman, Brooke
    Klass, Nicole
    Bastin, Benjamin
    Donofrio, Robert
    JOURNAL OF AOAC INTERNATIONAL, 2020, 103 (04) : 1112 - 1118
  • [27] Evaluation of the 3M™ Petrifilm™ Rapid Yeast and Mold Count Plate for the Enumeration of Yeast and Mold in Food: Collaborative Study, First Action 2014.05
    Bird, Patrick
    Flannery, Jonathan
    Crowley, Erin
    Agin, James
    Goins, David
    Jechorek, Robert
    JOURNAL OF AOAC INTERNATIONAL, 2015, 98 (03) : 767 - 783
  • [29] 3M™ Petrifilm™ Staph Express Count plate method for the enumeration of Staphylococcus aureus in selected types of processed and prepared foods:: Collaborative study
    Silbernagel, KM
    Jechorek, RP
    Carver, CN
    Horter, BL
    Lindberg, KG
    JOURNAL OF AOAC INTERNATIONAL, 2003, 86 (05) : 954 - 962
  • [30] 3M™ Petrifilm™ Staph Express Count plate method for the enumeration of Staphylococcus aureus in selected types of meat, seafood, and poultry:: Collaborative study
    McMahon, WA
    Aleo, VA
    Schultz, AM
    Horter, BL
    Lindberg, KG
    JOURNAL OF AOAC INTERNATIONAL, 2003, 86 (05) : 947 - 953