Background: The 3M (TM) Petrifilm (TM) Rapid Yeast and Mold Count (RYM) Plate is a sample-ready culture medium system which contains nutrients supplemented with antibiotics, a cold-water-soluble gelling agent, and an indicator system that facilitates yeast and mold enumeration. Objective: The 3M Petrifilm RYM Plate was validated for the enumeration of yeast and mold in dried cannabis flower through the AOAC Emergency Response Validation process. Methods The performance of the 3M Petrifilm RYM Plate was compared to dichloran rose bengal chloramphenicol (DRBC) agar. Matrix data were normalized by log(10) transformation and performance indicators included repeatability, difference of means, and inclusivity/exclusivity. Results: These studies demonstrated the 3M Petrifilm RYM Plate method detects and enumerates yeasts and molds from dried cannabis flower at low, medium, and high contamination levels. The average log counts at 25 or 28 degrees C for 60 to 72 h were equivalent to the average log counts of the DRBC reference method at low, medium and high levels. In strain studies, all 71 yeasts and molds tested produced typical colony morphology on 3M Petrifilm RYM Plates. Of the 32 non-target bacterial strains tested, none were detected on 3M Petrifilm RYM Plates. Conclusion: The 3M Petrifilm RYM Plate is a reliable method for the enumeration of live yeast and mold in dried cannabis flower. Highlights: The 3M Petrifilm RYM Plate allows for rapid detection of yeast and mold within 60 to 72h of incubation. Up to 40 sample-ready plates can be stacked during incubation to save space.
机构:
3M Food Safety Department, 3M Center, Bldg. 260-6B-01, St. Paul,MN,55144-1000, United States3M Food Safety Department, 3M Center, Bldg. 260-6B-01, St. Paul,MN,55144-1000, United States
Schumacher, April
Lingle, Cari
论文数: 0引用数: 0
h-index: 0
机构:
3M Food Safety Department, 3M Center, Bldg. 260-6B-01, St. Paul,MN,55144-1000, United States3M Food Safety Department, 3M Center, Bldg. 260-6B-01, St. Paul,MN,55144-1000, United States
Lingle, Cari
Silbernagel, Karen M.
论文数: 0引用数: 0
h-index: 0
机构:
3M Food Safety Department, 3M Center, Bldg. 260-6B-01, St. Paul,MN,55144-1000, United States3M Food Safety Department, 3M Center, Bldg. 260-6B-01, St. Paul,MN,55144-1000, United States
机构:
Hardy Diagnost, Tech Serv, 1430 West McCoy Lane, Santa Maria, CA 93455 USAHardy Diagnost, Tech Serv, 1430 West McCoy Lane, Santa Maria, CA 93455 USA
Hamilton, Lauren
Klavins, Anna
论文数: 0引用数: 0
h-index: 0
机构:
Hardy Diagnost, Tech Serv, 1430 West McCoy Lane, Santa Maria, CA 93455 USAHardy Diagnost, Tech Serv, 1430 West McCoy Lane, Santa Maria, CA 93455 USA
Klavins, Anna
Malherbe, Rianna
论文数: 0引用数: 0
h-index: 0
机构:
Hardy Diagnost, Tech Serv, 1430 West McCoy Lane, Santa Maria, CA 93455 USAHardy Diagnost, Tech Serv, 1430 West McCoy Lane, Santa Maria, CA 93455 USA
Malherbe, Rianna
Youngblood, Jessa
论文数: 0引用数: 0
h-index: 0
机构:
Hardy Diagnost, Mkt, 1430 West McCoy Lane, Santa Maria, CA 93455 USAHardy Diagnost, Tech Serv, 1430 West McCoy Lane, Santa Maria, CA 93455 USA
Youngblood, Jessa
Ito, Yusuke
论文数: 0引用数: 0
h-index: 0
机构:
Nissui Pharmaceut Co Ltd, Int Sales, Taito Ku, 3-24-6 Ueno, Tokyo 1100005, JapanHardy Diagnost, Tech Serv, 1430 West McCoy Lane, Santa Maria, CA 93455 USA
Ito, Yusuke
Hsiung, Andre
论文数: 0引用数: 0
h-index: 0
机构:
Hardy Diagnost, 1430 West McCoy Lane, Santa Maria, CA 93455 USAHardy Diagnost, Tech Serv, 1430 West McCoy Lane, Santa Maria, CA 93455 USA