Single- and Multi-Channel Modulation Detection in Cochlear Implant Users

被引:9
|
作者
Galvin, John J., III [1 ,2 ,3 ,4 ]
Oba, Sandy [1 ,2 ]
Fu, Qian-Jie [1 ,2 ]
Baskent, Deniz [3 ,4 ]
机构
[1] House Res Inst, Div Commun & Auditory Neurosci, Los Angeles, CA 90057 USA
[2] Univ Calif Los Angeles, David Geffen Sch Med, Dept Head & Neck Surg, Los Angeles, CA 90095 USA
[3] Univ Groningen, Univ Med Ctr Groningen, Dept Otorhinolaryngol Head & Neck Surg, Groningen, Netherlands
[4] Univ Groningen, Univ Med Ctr Groningen, Grad Sch Med Sci, Res Sch Behav & Cognit Neurosci, Groningen, Netherlands
来源
PLOS ONE | 2014年 / 9卷 / 06期
基金
美国国家卫生研究院;
关键词
CARRIER PULSE-RATE; AMPLITUDE-MODULATION; INTENSITY DISCRIMINATION; SPEECH RECOGNITION; STIMULATION RATE; LOUDNESS; PERCEPTION; LISTENERS; NOISE; SITE;
D O I
10.1371/journal.pone.0099338
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Single-channel modulation detection thresholds (MDTs) have been shown to predict cochlear implant (CI) users' speech performance. However, little is known about multi-channel modulation sensitivity. Two factors likely contribute to multichannel modulation sensitivity: multichannel loudness summation and the across-site variance in single-channel MDTs. In this study, single- and multi-channel MDTs were measured in 9 CI users at relatively low and high presentation levels and modulation frequencies. Single-channel MDTs were measured at widely spaced electrode locations, and these same channels were used for the multichannel stimuli. Multichannel MDTs were measured twice, with and without adjustment for multichannel loudness summation (i.e., at the same loudness as for the single-channel MDTs or louder). Results showed that the effect of presentation level and modulation frequency were similar for single- and multi-channel MDTs. Multichannel MDTs were significantly poorer than single-channel MDTs when the current levels of the multichannel stimuli were reduced to match the loudness of the single-channel stimuli. This suggests that, at equal loudness, single-channel measures may over-estimate CI users' multichannel modulation sensitivity. At equal loudness, there was no significant correlation between the amount of multichannel loudness summation and the deficit in multichannel MDTs, relative to the average single-channel MDT. With no loudness compensation, multichannel MDTs were significantly better than the best single-channel MDT. The across-site variance in single-channel MDTs varied substantially across subjects. However, the across-site variance was not correlated with the multichannel advantage over the best single channel. This suggests that CI listeners combined envelope information across channels instead of attending to the best channel.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Auditory perception in single-channel cochlear implant users reimplanted with a multichannel device
    Szuchnik, J
    Skarzynski, H
    Geremek, A
    Lorens, A
    4TH EUROPEAN CONGRESS OF OTO-RHINO-LARYNGOLOGY HEAD AND NECK SURGERY, VOLS 1 AND 2, 2000, : 173 - 176
  • [32] Priority users in a multi-channel system
    Burrell, Anthony
    Papantoni-Kazakos, P.
    2006 40TH ANNUAL CONFERENCE ON INFORMATION SCIENCES AND SYSTEMS, VOLS 1-4, 2006, : 1218 - 1223
  • [33] Gap detection in single- and multiple-channel stimuli by LAURA cochlear implantees
    van Wieringen, A
    Wouters, J
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1999, 106 (04): : 1925 - 1939
  • [34] Gap detection in single- and multiple-channel stimuli by LAURA cochlear implantees
    Van, Wieringen, Astrid
    Wouters, Jan
    Journal of the Acoustical Society of America, 1999, 106 (4 I): : 1925 - 1939
  • [35] Complex Spectral Mapping for Single- and Multi-Channel Speech Enhancement and Robust ASR
    Wang, Zhong-Qiu
    Wang, Peidong
    Wang, DeLiang
    IEEE-ACM TRANSACTIONS ON AUDIO SPEECH AND LANGUAGE PROCESSING, 2020, 28 : 1778 - 1787
  • [36] The application and computer simulation of multi-channel cochlear implant based on all phase DFT filter
    Tian, Lan
    Hou, Zhengxin
    Pang, Zhimin
    2007 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, VOL IV, PTS 1-3, 2007, : 701 - +
  • [37] An Efficient Algorithm for Single-/Multi-channel SAR Superresolution Imaging of Large Scenes
    Li, Zenghui
    Yin, Junjun
    Yang, Jian
    CONFERENCE PROCEEDINGS OF 2013 ASIA-PACIFIC CONFERENCE ON SYNTHETIC APERTURE RADAR (APSAR), 2013, : 368 - 372
  • [38] MUTUAL LEARNING OF SINGLE- AND MULTI-CHANNEL END-TO-END NEURAL DIARIZATION
    Horiguchi, Shota
    Takashima, Yuki
    Watanabe, Shinji
    Garcia, Paola
    2022 IEEE SPOKEN LANGUAGE TECHNOLOGY WORKSHOP, SLT, 2022, : 620 - 625
  • [39] Energy Detection under IQ Imbalance with Single- and Multi-Channel Direct-Conversion Receiver: Analysis and Mitigation
    Gokceoglu, Ahmet
    Dikmese, Sener
    Valkama, Mikko
    Renfors, Markku
    IEEE JOURNAL ON SELECTED AREAS IN COMMUNICATIONS, 2014, 32 (03) : 411 - 424
  • [40] Temporal fluorescence rejection in Raman spectroscopy using femtosecond up-conversion with single- and multi-channel detection
    Mandal, D
    Mizuno, M
    Tahara, T
    JOURNAL OF MOLECULAR STRUCTURE, 2005, 735 : 189 - 195