New dynamic diamond anvil cells for tera-pascal per second fast compression x-ray diffraction experiments

被引:35
|
作者
Jenei, Zs. [1 ]
Liermann, H. P. [2 ]
Husband, R. [2 ]
Mendez, A. S. J. [2 ]
Pennicard, D. [2 ]
Marquardt, H. [3 ]
O'Bannon, E. F. [1 ]
Pakhomova, A. [2 ]
Konopkova, Z. [2 ,4 ]
Glazyrin, K. [1 ]
Wendt, M. [2 ]
Wenz, S. [2 ]
McBride, E. E. [2 ,7 ]
Morgenroth, W. [5 ]
Winkler, B. [5 ]
Rothkirch, A. [2 ]
Hanfland, M. [6 ]
Evans, W. J. [1 ]
机构
[1] Lawrence Livermore Natl Lab, High Pressure Phys Grp, 7000 East Ave,L-041, Livermore, CA 94550 USA
[2] DESY, Photon Sci, Notkestr 85, D-22607 Hamburg, Germany
[3] Univ Oxford, Dept Earth Sci, South Parks Poad, Oxford OX1 3AN, England
[4] European Xray Free Electron Laser Facil GmbH, Holzkoppel 4, D-22869 Schenefeld, Germany
[5] Goethe Univ Frankfurt, Dept Geosci, Arbeitsgrp Kristallog, D-60438 Frankfurt, Germany
[6] ESPF, European Synchrotron, 71 Ave Martyrs, F-38000 Grenoble, France
[7] SLAC Natl Accelerator Lab, 2575 Sand Hill Pd, Menlo Pk, CA 94025 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2019年 / 90卷 / 06期
关键词
EQUATION-OF-STATE; D2O ICE VII; HIGH-PRESSURE; POWDER DIFFRACTION; PHASE-TRANSITIONS; ALPHA-QUARTZ;
D O I
10.1063/1.5098993
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Fast compression experiments performed using dynamic diamond anvil cells (dDACs) employing piezoactuators offer the opportunity to study compression-rate dependent phenomena. In this paper, we describe an experimental setup which allows us to perform time-resolved x-ray diffraction during the fast compression of materials using improved dDACs. The combination of the high flux available using a 25.6 keV x-ray beam focused with a linear array of compound refractive lenses and the two fast GaAs LAMBDA detectors available at the Extreme Conditions Beamline (P02.2) at PETRA III enables the collection of x-ray diffraction patterns at an effective repetition rate of up to 4 kHz. Compression rates of up to 160 TPa/s have been achieved during the compression of gold in a 2.5 ms fast compression using improved dDAC configurations with more powerful piezoactuators. The application of this setup to low-Z compounds at lower compression rates is described, and the high temporal resolution of the setup is demonstrated. The possibility of applying finely tuned pressure profiles opens opportunities for future research, such as using oscillations of the piezoactuator to mimic propagation of seismic waves in the Earth.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] In-situ combined X-ray diffraction and electrical resistance measurements at high pressures and temperatures in diamond anvil cells
    Kuznetsov, A. Yu.
    Dmitriev, V.
    Volkova, Y.
    Kurnosov, A.
    Dubrovinskaia, N.
    Dubrovinsky, L.
    HIGH PRESSURE RESEARCH, 2007, 27 (02) : 213 - 222
  • [42] Fast X-ray powder diffraction on I11 at Diamond
    Thompson, Stephen P.
    Parker, Julia E.
    Marchal, Julien
    Potter, Jonathan
    Birt, Adrian
    Yuan, Fajin
    Fearn, Richard D.
    Lennie, Alistair R.
    Street, Steven R.
    Tang, Chiu C.
    JOURNAL OF SYNCHROTRON RADIATION, 2011, 18 : 637 - 648
  • [43] New developments in high-pressure X-ray diffraction beamline for diamond anvil cell at SPring-8
    NHirao
    SIKawaguchi
    KHirose
    KShimizu
    EOhtani
    YOhishi
    Matter and Radiation at Extremes, 2020, 5 (01) : 68 - 77
  • [44] Nonhydrostatic compression of gold powder to 60 GPa in a diamond anvil cell: estimation of compressive strength from x-ray diffraction data
    Singh, A. K.
    Liermann, H. P.
    Saxena, S. K.
    Mao, H. K.
    Devi, S. Usha
    JOURNAL OF PHYSICS-CONDENSED MATTER, 2006, 18 (25) : S969 - S978
  • [45] New developments in high-pressure X-ray diffraction beamline for diamond anvil cell at SPring-8
    Hirao, N.
    Kawaguchi, S., I
    Hirose, K.
    Shimizu, K.
    Ohtani, E.
    Ohishi, Y.
    MATTER AND RADIATION AT EXTREMES, 2020, 5 (01)
  • [46] New detector for fast X-ray diffraction measurements
    不详
    ZKG INTERNATIONAL, 2005, 58 (10): : 26 - 26
  • [47] Investigation into high-pressure behavior of MnTiO3:X-ray diffraction and Raman spectroscopy with diamond anvil cells
    Leonid Dubrovinsky
    Geoscience Frontiers, 2011, (01) : 107 - 114
  • [48] High pressure synchrotron X-ray diffraction studies of biological molecules using the diamond anvil technique
    Czeslik, C
    Malessa, R
    Winter, R
    Rapp, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 368 (03): : 847 - 851
  • [49] High resolution powder X-ray diffraction measurements in Guinier geometry using a diamond anvil cell
    Yousuf, M
    Rajan, KG
    Sahu, PC
    Shekar, NVC
    Subramanian, N
    Sekar, M
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 1996, 34 (09) : 632 - 650
  • [50] Thermal pressure in the laser-heated diamond-anvil cell: An X-ray diffraction study
    Andrault, D
    Fiquet, G
    Itie, JP
    Richet, P
    Gillet, P
    Hausermann, D
    Hanfland, M
    EUROPEAN JOURNAL OF MINERALOGY, 1998, 10 (05) : 931 - 940