New dynamic diamond anvil cells for tera-pascal per second fast compression x-ray diffraction experiments

被引:35
|
作者
Jenei, Zs. [1 ]
Liermann, H. P. [2 ]
Husband, R. [2 ]
Mendez, A. S. J. [2 ]
Pennicard, D. [2 ]
Marquardt, H. [3 ]
O'Bannon, E. F. [1 ]
Pakhomova, A. [2 ]
Konopkova, Z. [2 ,4 ]
Glazyrin, K. [1 ]
Wendt, M. [2 ]
Wenz, S. [2 ]
McBride, E. E. [2 ,7 ]
Morgenroth, W. [5 ]
Winkler, B. [5 ]
Rothkirch, A. [2 ]
Hanfland, M. [6 ]
Evans, W. J. [1 ]
机构
[1] Lawrence Livermore Natl Lab, High Pressure Phys Grp, 7000 East Ave,L-041, Livermore, CA 94550 USA
[2] DESY, Photon Sci, Notkestr 85, D-22607 Hamburg, Germany
[3] Univ Oxford, Dept Earth Sci, South Parks Poad, Oxford OX1 3AN, England
[4] European Xray Free Electron Laser Facil GmbH, Holzkoppel 4, D-22869 Schenefeld, Germany
[5] Goethe Univ Frankfurt, Dept Geosci, Arbeitsgrp Kristallog, D-60438 Frankfurt, Germany
[6] ESPF, European Synchrotron, 71 Ave Martyrs, F-38000 Grenoble, France
[7] SLAC Natl Accelerator Lab, 2575 Sand Hill Pd, Menlo Pk, CA 94025 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2019年 / 90卷 / 06期
关键词
EQUATION-OF-STATE; D2O ICE VII; HIGH-PRESSURE; POWDER DIFFRACTION; PHASE-TRANSITIONS; ALPHA-QUARTZ;
D O I
10.1063/1.5098993
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Fast compression experiments performed using dynamic diamond anvil cells (dDACs) employing piezoactuators offer the opportunity to study compression-rate dependent phenomena. In this paper, we describe an experimental setup which allows us to perform time-resolved x-ray diffraction during the fast compression of materials using improved dDACs. The combination of the high flux available using a 25.6 keV x-ray beam focused with a linear array of compound refractive lenses and the two fast GaAs LAMBDA detectors available at the Extreme Conditions Beamline (P02.2) at PETRA III enables the collection of x-ray diffraction patterns at an effective repetition rate of up to 4 kHz. Compression rates of up to 160 TPa/s have been achieved during the compression of gold in a 2.5 ms fast compression using improved dDAC configurations with more powerful piezoactuators. The application of this setup to low-Z compounds at lower compression rates is described, and the high temporal resolution of the setup is demonstrated. The possibility of applying finely tuned pressure profiles opens opportunities for future research, such as using oscillations of the piezoactuator to mimic propagation of seismic waves in the Earth.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] A compact x-ray diffraction system for dynamic compression experiments on pulsed-power generators
    Ao, T.
    Morgan, D. V.
    Stoltzfus, B. S.
    Austin, K. N.
    Usher, J.
    Breden, E.
    Pacheco, L. M.
    Dean, S.
    Brown, J. L.
    Duwal, S.
    Fan, H.
    Kalita, P.
    Knudson, M. D.
    Rodriguez, M. A.
    Lane, J. M. D.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2022, 93 (05):
  • [32] Portable double-sided laser-heating system for Mossbauer spectroscopy and X-ray diffraction experiments at synchrotron facilities with diamond anvil cells
    Kupenko, I.
    Dubrovinsky, L.
    Dubrovinskaia, N.
    McCammon, C.
    Glazyrin, K.
    Bykova, E.
    Ballaran, T. Boffa
    Sinmyo, R.
    Chumakov, A. I.
    Potapkin, V.
    Kantor, A.
    Rueffer, R.
    Hanfland, M.
    Crichton, W.
    Merlini, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (12):
  • [33] X-ray absorption spectroscopy under high pressures in diamond anvil cells
    Sapelkin, AV
    Bayliss, SC
    HIGH PRESSURE RESEARCH, 2002, 21 (06) : 315 - 329
  • [34] Ultrasonic interferometry and X-ray measurements on MgO in a new diamond anvil cell
    Reichmann, HJ
    Angel, RJ
    Spetzler, H
    Bassett, WA
    AMERICAN MINERALOGIST, 1998, 83 (11-12) : 1357 - 1360
  • [35] Diamond anvil cell radial x-ray diffraction program at the National Synchrotron Light Source
    Hu, J. Z.
    Mao, H. K.
    Shu, J. F.
    Guo, Q. Z.
    Liu, H. Z.
    JOURNAL OF PHYSICS-CONDENSED MATTER, 2006, 18 (25) : S1091 - S1096
  • [36] A versatile diamond anvil cell for X-ray inelastic, diffraction and imaging studies at synchrotron facilities
    Petitgirard, Sylvain
    Jacobs, Jeroen
    Cerantola, Valerio
    Collings, Ines E.
    Tucoulou, Remi
    Dubrovinsky, Leonid
    Sahle, Christoph J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (09):
  • [37] A NEW DIAMOND-ANVIL CELL FOR X-RAY DIFFUSE-SCATTERING
    FUJII, Y
    OHISHI, Y
    KOWAKA, M
    HAMAYA, N
    TAKEMURA, K
    HOSHINO, S
    TSUJI, K
    MINOMURA, S
    PHYSICA B & C, 1986, 139 (1-3): : 907 - 909
  • [38] NEW DIAMOND-ANVIL CELL FOR X-RAY DIFFUSE SCATTERING.
    Fujii, Y.
    Ohishi, Y.
    Kowaka, M.
    Hamaya, N.
    Takemura, K.
    Hoshino, S.
    Tsuji, K.
    Minomura, S.
    Physica B: Physics of Condensed Matter & C: Atomic, Molecular and Plasma Physics, Optics, 1985, 139-140 : 907 - 909
  • [39] X-ray diffraction patterns from samples in the laser-heated diamond anvil cell
    Panero, WR
    Jeanloz, R
    JOURNAL OF APPLIED PHYSICS, 2002, 91 (05) : 2769 - 2778
  • [40] Internal resistive heating in diamond anvil cell for in situ x-ray diffraction and Raman scattering
    Zha, CS
    Bassett, WA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (03): : 1255 - 1262