Vibrotactile evaluation: Osseointegrated versus socket-suspended transfemoral prostheses

被引:47
|
作者
Haggstrom, Eva [1 ,2 ]
Hagberg, Kerstin [1 ,2 ]
Rydevik, Bjorn [2 ]
Branemark, Rickard [2 ]
机构
[1] Univ Gothenburg, Sahlgrenska Univ Hosp, Dept Prosthet & Orthot, SE-41285 Gothenburg, Sweden
[2] Univ Gothenburg, Sahlgrenska Univ Hosp, Dept Orthopaed, SE-41285 Gothenburg, Sweden
来源
关键词
artificial limb; osseointegration; osseoperception; prosthesis; prosthetic foot; prosthetic knee; sensibility test; transfemoral amputation; vibrometric measurement; vibrotactile sensibility; TRANS-FEMORAL AMPUTEE; AMPUTATION PROSTHESES; REHABILITATION; VIBRATION; IMPLANTS; GAIT; STIMULATION; PERCEPTION; NEUROPATHY; ANCHORAGE;
D O I
10.1682/JRRD.2012.08.0135
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
This study investigated detection thresholds of vibrometric stimuli in patients with transfemoral amputation supplied with osseointegrated (OI) and socket-suspended prostheses. It included 17 patients tested preoperatively with socket-suspended prostheses and after 2 yr with OI prostheses and a control group (n = 17) using socket-suspended prostheses, evaluated once. Assessments on the prosthetic and intact feet were conducted at six frequencies (8, 16, 32, 64, 125, and 250 Hz). Furthermore, measurements were conducted to investigate how vibrometric signals are transmitted through a test prosthesis. The results showed that the OI group had improved ability to detect vibrations through the prosthesis at 125 Hz (p = 0.01) at follow-up compared with the preoperative measurement. Compared with the control group, the 01 group at follow-up had better ability to detect high frequency vibrations through the prosthesis (125 Hz, p = 0.02; 250 Hz, p = 0.03). The vibrometric signal transmitted through the test prosthesis was reduced at 8, 125, and 250 Hz but was amplified at 16, 32, and 64 Hz. Differences between the OI and the control groups were found in the highest frequencies in which the test prosthesis showed reduction of the vibrometric signal. The study provides insight into the mechanisms of vibration transmission between the exterior and bone-anchored as well as socket-suspended amputation prostheses.
引用
收藏
页码:1423 / 1434
页数:12
相关论文
共 50 条
  • [41] Evaluation of Optimal Vibrotactile Feedback for Force-Controlled Upper Limb Myoelectric Prostheses
    Gonzalez-Rodriguez, Andrea
    Ramon, Jose L.
    Morell, Vicente
    Garcia, Gabriel J.
    Pomares, Jorge
    Jara, Carlos A.
    Ubeda, Andres
    SENSORS, 2019, 19 (23)
  • [42] Comparison of functional outcome and patient satisfaction between patients with socket prosthesis and patients treated with transcutaneous osseointegrated prosthetic systems (TOPS) after transfemoral amputation
    Oergel, Marcus
    Schwarze, Frederik
    Graulich, Tilman
    Krettek, Christian
    Weidemann, Friederike
    Aschoff, Horst-Heinrich
    Winkelmann, Marcel
    Ranker, Alexander
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2022, 48 (06) : 4867 - 4876
  • [43] Comparison of functional outcome and patient satisfaction between patients with socket prosthesis and patients treated with transcutaneous osseointegrated prosthetic systems (TOPS) after transfemoral amputation
    Marcus Örgel
    Frederik Schwarze
    Tilman Graulich
    Christian Krettek
    Friederike Weidemann
    Horst-Heinrich Aschoff
    Marcel Winkelmann
    Alexander Ranker
    European Journal of Trauma and Emergency Surgery, 2022, 48 : 4867 - 4876
  • [44] Analysis of Pressure Distribution in Transfemoral Prosthetic Socket for Prefabrication Evaluation via the Finite Element Method
    Jamaludin, Mohd Syahmi
    Hanafusa, Akihiko
    Shinichirou, Yamamoto
    Agarie, Yukio
    Otsuka, Hiroshi
    Ohnishi, Kengo
    BIOENGINEERING-BASEL, 2019, 6 (04):
  • [45] PRELIMINARY EVALUATION OF A KNEE-ANKLE-FOOT ORTHOSIS FOR THE EMULATION OF TRANSFEMORAL PROSTHESIS SOCKET LOADS
    Dawley, James A.
    Romanazzi, Andrew M.
    Fite, Kevin B.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE 2011, PTS A AND B, 2011, : 1225 - 1226
  • [46] Preliminary Evaluation of a New Control Approach to Achieve Speed Adaptation in Robotic Transfemoral Prostheses
    Lenzi, T.
    Hargrove, L. J.
    Sensinger, J. W.
    2014 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS 2014), 2014, : 2049 - 2054
  • [47] The Evaluation of Daily Life Activities after Application of an Osseointegrated Prosthesis Fixation in a Bilateral Transfemoral Amputee A Case Study
    Schalk, Stephanie A. F.
    Jonkergouw, Niels
    van der Meer, Fred
    Swaan, Willem M.
    Aschoff, Horst-H.
    van der Wurff, Peter
    MEDICINE, 2015, 94 (36)
  • [48] Loading characteristics data applied on osseointegrated implant by transfemoral bone-anchored prostheses fitted with state-of-the-art components during daily activities
    Frossard, Laurent
    Laux, Stefan
    Geada, Marta
    Heym, Peter Paul
    Lechler, Knut
    DATA IN BRIEF, 2022, 41
  • [49] Evaluation of the Effects of Geometrical Changes in Prosthetic Socket Towards Transfemoral Residuum via Finite Element Method
    Jamaludin, Mohd Syahmi
    Hanafusa, Akihiko
    Yamamoto, Shin-Ichirou
    Agarie, Yukio
    Otsuka, Hiroshi
    Onishi, Kengo
    2018 IEEE-EMBS CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES), 2018, : 314 - 319
  • [50] An insight into Transfemoral Prostheses: Materials, modelling, simulation, fabrication, testing, clinical evaluation and performance perspectives
    Amudhan, K.
    Vasanthanathan, A.
    Thilak, J. Anish Jafrin
    EXPERT REVIEW OF MEDICAL DEVICES, 2022, 19 (02) : 123 - 140