Analysis of Pressure Distribution in Transfemoral Prosthetic Socket for Prefabrication Evaluation via the Finite Element Method

被引:9
|
作者
Jamaludin, Mohd Syahmi [1 ]
Hanafusa, Akihiko [1 ]
Shinichirou, Yamamoto [1 ]
Agarie, Yukio [2 ]
Otsuka, Hiroshi [3 ]
Ohnishi, Kengo [4 ]
机构
[1] Shibaura Inst Technol, Dept Biosci & Engn, Tokyo 1358548, Japan
[2] Niigata Univ Hlth & Welf, Dept Supporting Prosthet Orthot, Niigata 9503102, Japan
[3] Univ Human Arts & Sci, Dept Prosthet & Orthot, Iwatsuki Ward, Iwatsuki, Saitama 3390077, Japan
[4] Tokyo Denki Univ, Dept Sci & Engn, Tokyo 1208551, Japan
来源
BIOENGINEERING-BASEL | 2019年 / 6卷 / 04期
关键词
3D model; Biomechanics; Finite element analysis; Finite element method; Prosthetic socket; Transfemoral residuum;
D O I
10.3390/bioengineering6040098
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
In this study, we estimated and validated the pressure distribution profile between the residuum and two types of prosthetic sockets for transfemoral amputees by utilizing a finite element analysis. Correct shaping of the socket for an appropriate load distribution is a critical process in the design of lower-limb prosthesis sockets. The pressure distribution profile provides an understanding of the relationship between the socket design and the level of subject comfortability. Estimating the pressure profile is important, as it helps improve the prosthesis through an evaluation of the socket design before it undergoes the fabrication process. This study focused on utilizing a magnetic resonance imaging (MRI)-based three-dimensional (3D) model inside a predetermined finite element simulation. The simulation was predetermined by mimicking the actual socket-fitting environment. The results showed that the potential MRI-based 3D model simulation could be used as an estimation tool for a pressure distribution profile due to the high correlation coefficient value (R-2 > 0.8) calculated when the pressure profiles were compared to the experiment data. The simulation also showed that the pressure distribution in the proximal area was higher (similar to 30%) than in the distal area of the prosthetic socket for every subject. The results of this study will be of tremendous interest for fabricators through the use of a finite element model as an alternative method for the prefabrication and evaluation of prosthetic sockets. In future prosthetic socket fabrications, less intervention will be required in the development of a socket, and the participation of the subject in the socket-fitting session will not be necessary. The results suggest that this study will contribute to expanding the development of an overall prefabrication evaluation system to allow healthcare providers and engineers to simulate the fit and comfort of transfemoral prosthetics.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Evaluation of the Effects of Geometrical Changes in Prosthetic Socket Towards Transfemoral Residuum via Finite Element Method
    Jamaludin, Mohd Syahmi
    Hanafusa, Akihiko
    Yamamoto, Shin-Ichirou
    Agarie, Yukio
    Otsuka, Hiroshi
    Onishi, Kengo
    2018 IEEE-EMBS CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES), 2018, : 314 - 319
  • [2] Finite Element Analysis of Donning Procedure of a Prosthetic Transfemoral Socket
    Lacroix, Damien
    Ramirez Patino, Juan Fernando
    ANNALS OF BIOMEDICAL ENGINEERING, 2011, 39 (12) : 2972 - 2983
  • [3] Finite Element Analysis of Donning Procedure of a Prosthetic Transfemoral Socket
    Damien Lacroix
    Juan Fernando Ramírez Patiño
    Annals of Biomedical Engineering, 2011, 39 : 2972 - 2983
  • [4] Analysis of compression/release stabilized transfemoral prosthetic socket by finite element modelling method
    Meng, Zhaojian
    Wong, Duo Wai-Chi
    Zhang, Ming
    Leung, Aaron Kam-Lun
    MEDICAL ENGINEERING & PHYSICS, 2020, 83 : 123 - 129
  • [5] Parametric optimization and design validation based on finite element analysis of hybrid socket adapter for transfemoral prosthetic knee
    Kumar, Neelesh
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2014, 38 (05) : 363 - 368
  • [6] Influence of Gait Cycle Loads on Stress Distribution at The Residual Limb/Socket Interface of Transfemoral Amputees: A Finite Element Analysis
    Sofía C. Henao
    Camila Orozco
    Juan Ramírez
    Scientific Reports, 10
  • [7] Influence of Gait Cycle Loads on Stress Distribution at The Residual Limb/Socket Interface of Transfemoral Amputees: A Finite Element Analysis
    Henao, Sofia C.
    Orozco, Camila
    Ramirez, Juan
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [8] Biomechanical analysis of prosthetic liners in transfemoral amputees using finite element modeling
    Messaad, Taieb
    Baltach, Abdelghani
    Zagane, Mohammed El Sallah
    Boudjemaa, Ismail
    Messaad, Mokhtar
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2025, 47 (02)
  • [9] Generic, geometric finite element analysis of the transtibial residual limb and prosthetic socket
    SilverThorn, MB
    Childress, DS
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 1997, 34 (02): : 171 - 186
  • [10] Analysis of Pressure Distribution of the Bolted Joints Based on the Finite Element Method
    Sheng-ao Wang
    Min Zhu
    Fei Wu
    Tian-xi Liang
    Zhao-qun Shao
    Yi-long Liu
    International Journal of Steel Structures, 2023, 23 : 586 - 598