Biochemical assay for serum creatinine detection through a 1-methylhydantoin and cobalt complex

被引:12
|
作者
Dasgupta, Pallavi [1 ]
Kumar, Vinay [2 ]
Krishnaswamy, Patnam R. [1 ]
Bhat, Navakanta [1 ]
机构
[1] Indian Inst Sci, Ctr Nanosci & Engn, Bengaluru, India
[2] PathShodh Healthcare Pvt Ltd, Bengaluru, India
关键词
BIOSENSOR; UREA;
D O I
10.1039/d0ra06470j
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Creatinine is a reliable indicator of renal function and degradation of muscular metabolism. Current analytical techniques for its measurement are limited by their cost and requirement of sophisticated instruments. In this work, we report a highly sensitive amperometric biosensor for creatinine by utilizing the one-step selective conversion of creatinine by creatinine deiminase. The novelty of the proposed sensor relies on the measurement of N-methylhydantoin produced in the reaction. The sensing chemistry comprises of creatinine deiminase as the receptor for creatinine, cobalt chloride as the electrochemically active recognition element, and methylene blue as the redox mediator. The sensing chemistry is immobilized on the glassy carbon electrode surface by physisorption. We have been able to provide a standalone device that reliably quantifies creatinine in serum and even whole blood, without any sample pre-processing. It is possible to measure creatinine in the clinically relevant range from 0.8 to 4 mg dL(-1) with this approach.
引用
收藏
页码:39092 / 39101
页数:10
相关论文
共 50 条
  • [31] Enzyme-linked immunosorbent assay for detection of feline herpesvirus 1 IgG in serum, aqueous humor, and cerebrospinal fluid
    Dawson, DA
    Carman, J
    Collins, J
    Hill, S
    Lappin, MR
    JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 1998, 10 (04) : 315 - 319
  • [32] The utility of a rapid serum assay in the detection of HIV-1 in a mobile youth specific counseling and testing site.
    Peralta, L
    Constantine, N
    Miller, S
    Hoehn, L
    JOURNAL OF ADOLESCENT HEALTH, 1999, 24 (02) : 84 - 84
  • [33] DEVELOPMENT OF A SEMIQUANTITATIVE ASSAY FOR THE DETECTION OF RUBELLA SPECIFIC IGM IN HUMAN SERUM ON THE TECHNICON IMMUNO-1(R) ANALYZER
    LEW, F
    PAYNE, R
    FOLTZ, M
    SWARTZELL, C
    WELLS, T
    DWYER, R
    CLINICAL CHEMISTRY, 1995, 41 (06) : S64 - S64
  • [34] AN ENZYME-LINKED-IMMUNOSORBENT-ASSAY FOR THE DETECTION AND QUANTITATION OF ANTI-JO-1 ANTIBODY IN HUMAN-SERUM
    BISWAS, T
    MILLER, FW
    TAKAGAKI, Y
    PLOTZ, PH
    JOURNAL OF IMMUNOLOGICAL METHODS, 1987, 98 (02) : 243 - 248
  • [35] A fluorescent reporter assay for the detection of ligands acting through G1 protein-coupled receptors
    Xing, H
    Tran, HC
    Knapp, TE
    Negulescu, PA
    Pollok, BA
    JOURNAL OF RECEPTOR AND SIGNAL TRANSDUCTION RESEARCH, 2000, 20 (04): : 189 - +
  • [36] An immunocapture-LC-MS-based assay for serum SPINK1 allows simultaneous quantification and detection of SPINK1 variants
    Suvi Ravela
    Leena Valmu
    Mykola Domanskyy
    Hannu Koistinen
    Leena Kylänpää
    Outi Lindström
    Jakob Stenman
    Esa Hämäläinen
    Ulf-Håkan Stenman
    Outi Itkonen
    Analytical and Bioanalytical Chemistry, 2018, 410 : 1679 - 1688
  • [37] An immunocapture-LC-MS-based assay for serum SPINK1 allows simultaneous quantification and detection of SPINK1 variants
    Ravela, Suvi
    Valmu, Leena
    Domanskyy, Mykola
    Koistinen, Hannu
    Kylanpaa, Leena
    Lindstrom, Outi
    Stenman, Jakob
    Hamalainen, Esa
    Stenman, Ulf-Hakan
    Itkonen, Outi
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (06) : 1679 - 1688
  • [38] Human serum albumin binding and cytotoxicity studies of surfactant-cobalt(III) complex containing 1,10-phenanthroline ligand
    Kumar, R. Senthil
    Paul, Preethy
    Riyasdeen, A.
    Wagnieres, Georges
    van den Bergh, Hubert
    Akbarsha, M. A.
    Arunachalam, S.
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2011, 86 (01) : 35 - 44
  • [39] Direct Detection of α-1 Antitrypsin in Serum Samples using Surface Plasmon Resonance with a New Aptamer-Antibody Sandwich Assay
    Kim, Suhee
    Lee, Hye Jin
    ANALYTICAL CHEMISTRY, 2015, 87 (14) : 7235 - 7240
  • [40] AUTOMATED-ASSAY OF METHYLMALONIC ACID IN SERUM AND URINE BY DERIVATIZATION WITH 1-PYRENYLDIAZOMETHANE, LIQUID-CHROMATOGRAPHY, AND FLUORESCENCE DETECTION
    SCHNEEDE, J
    UELAND, PM
    CLINICAL CHEMISTRY, 1993, 39 (03) : 392 - 399