EEG source localization sensitivity due to brain lesions modeling errors

被引:0
|
作者
Vatta, F [1 ]
Bruno, P [1 ]
Inchingolo, P [1 ]
机构
[1] Univ Trieste, DEEI, Trieste, Italy
关键词
electroencephalography; dipole localization; imaging; inhomogeneity; inverse problems; source localization;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
For accurate electroencephalogram-based (EEG) localization of neural sources correct modeling of brain lesions geometry and tissue conductivity is required. Lesion properties are derived from anatomical images like CT or MRI. According to imaging modality, lesion can appear of different size and shape. Conductivity parameters are taken from standard references, despite the large variability in the available data. The uncertainties in lesion conductivity assignment (LCA) and in determining exact lesion geometry affect source localization accuracy. The aim of this paper is to quantify the combined effect of these uncertainties on EEG dipole source localization accuracy. The study was conducted using an eccentric-spheres model of the head in which a modifiable eccentric bubble approximated various brain lesions. In 32 simulated pathological conditions the inverse dipole fitting procedure was carried out assuming an incorrect (under/overestimate) lesion dimension and conductivity. Errors in lesion modeling led to markedly wrong source reconstruction even for small differences between the actual lesion and its model. Localization errors up to 15.4 mm demonstrate the requirement of an accurate parametric setting of the model to achieve localization accuracy within few millimeters.
引用
收藏
页码:913 / 916
页数:4
相关论文
共 50 条
  • [41] Evaluation of linear registration algorithms for brain SPECT and the errors due to hypoperfusion lesions
    Radau, PE
    Slomka, PJ
    Julin, P
    Svensson, L
    Wahlund, LO
    MEDICAL PHYSICS, 2001, 28 (08) : 1660 - 1668
  • [42] EEG source localization of interictal epileptiform activity in patients with partial complex epilepsy:: Comparison between dipole modeling and brain distributed source models
    Santiago-Rodríguez, E
    Harmony, T
    Fernández-Bouzas, A
    Hernández, A
    Martínez-López, M
    Graef, A
    García, JC
    Silva-Pereyra, J
    Fernandez, T
    CLINICAL ELECTROENCEPHALOGRAPHY, 2002, 33 (01): : 42 - 47
  • [43] Accuracy of EEG source imaging of epileptic spikes in patients with large brain lesions
    Brodbeck, Verena
    Lascano, Agustina M.
    Spinelli, Laurent
    Seeck, Margitta
    Michel, Christoph M.
    CLINICAL NEUROPHYSIOLOGY, 2009, 120 (04) : 679 - 685
  • [44] Brain Signal Source Localization from EEG During Recall of the Aural Stimulation
    Tomohiro, Tada
    Akutagawa, Masatake
    Kaji, Yoshio
    Shichijo, Fumio
    Nagashino, Hirofumi
    Kinouchi, Yohsuke
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1075 - +
  • [45] Accuracy of EEG dipole source localization using implanted sources in the human brain
    Krings, T
    Chiappa, KH
    Cuffin, BN
    Cochius, JI
    Connolly, S
    Cosgrove, GR
    CLINICAL NEUROPHYSIOLOGY, 1999, 110 (01) : 106 - 114
  • [46] Brain Source Localization Techniques: Evaluation Study Using Simulated EEG Data
    Hyder, Rasha
    Kamel, Nidal
    Tang, Tong Boon
    Bornot, Jose
    2014 IEEE CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES), 2014, : 942 - 947
  • [47] Unmixing Oscillatory Brain Activity by EEG Source Localization and Empirical Mode Decomposition
    Hansen, Sofie Therese
    Hemakom, Apit
    Safeldt, Mads Gylling
    Krohne, Laerke Karen
    Madsen, Kristoffer Hougaard
    Siebner, Hartwig R.
    Mandic, Danilo P.
    Hansen, Lars Kai
    COMPUTATIONAL INTELLIGENCE AND NEUROSCIENCE, 2019, 2019
  • [48] A systematic review of EEG source localization techniques and their applications on diagnosis of brain abnormalities
    Asadzadeh, Shiva
    Rezaii, Tohid Yousefi
    Beheshti, Soosan
    Delpak, Azra
    Meshgini, Saeed
    JOURNAL OF NEUROSCIENCE METHODS, 2020, 339
  • [49] Effect of Brain-to-Skull Conductivity Ratio on EEG Source Localization Accuracy
    Wang, Gang
    Ren, Doutian
    BIOMED RESEARCH INTERNATIONAL, 2013, 2013
  • [50] Investigation of Brain Tissue Segmentation Error and its Effect on EEG Source Localization
    Shirvany, Yazdan
    Porras, Antonio R.
    Kowkabzadeh, Koushyar
    Mahmood, Qaiser
    Lui, Hoi-Shun
    Persson, Mikael
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 1522 - 1525