EEG source localization sensitivity due to brain lesions modeling errors

被引:0
|
作者
Vatta, F [1 ]
Bruno, P [1 ]
Inchingolo, P [1 ]
机构
[1] Univ Trieste, DEEI, Trieste, Italy
关键词
electroencephalography; dipole localization; imaging; inhomogeneity; inverse problems; source localization;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
For accurate electroencephalogram-based (EEG) localization of neural sources correct modeling of brain lesions geometry and tissue conductivity is required. Lesion properties are derived from anatomical images like CT or MRI. According to imaging modality, lesion can appear of different size and shape. Conductivity parameters are taken from standard references, despite the large variability in the available data. The uncertainties in lesion conductivity assignment (LCA) and in determining exact lesion geometry affect source localization accuracy. The aim of this paper is to quantify the combined effect of these uncertainties on EEG dipole source localization accuracy. The study was conducted using an eccentric-spheres model of the head in which a modifiable eccentric bubble approximated various brain lesions. In 32 simulated pathological conditions the inverse dipole fitting procedure was carried out assuming an incorrect (under/overestimate) lesion dimension and conductivity. Errors in lesion modeling led to markedly wrong source reconstruction even for small differences between the actual lesion and its model. Localization errors up to 15.4 mm demonstrate the requirement of an accurate parametric setting of the model to achieve localization accuracy within few millimeters.
引用
收藏
页码:913 / 916
页数:4
相关论文
共 50 条
  • [31] Application of Compressive Sensing for EEG Source Localization in Brain Computer Interfaces
    Zaitcev, Aleksandr
    Cook, Greg
    Liu, Wei
    Paley, Martyn
    Milne, Elizabeth
    2014 LOUGHBOROUGH ANTENNAS AND PROPAGATION CONFERENCE (LAPC), 2014, : 272 - 276
  • [32] EEG source localization for two dipoles in the brain using a combined method
    Li, ZM
    Zhang, Y
    Zhang, QY
    Akutagawa, M
    Nagashino, H
    Shichijo, F
    Kinouchi, Y
    INTELLIGENT DATA ENGINEERING AND AUTOMATED LEARNING IDEAL 2005, PROCEEDINGS, 2005, 3578 : 171 - 178
  • [33] Calibration of Low Density EEG Sensor Arrays for Brain Source Localization
    Zarghami, Tahereh
    Mir, Hasan S.
    Al-Nashash, Hasan
    NEURAL INFORMATION PROCESSING, ICONIP 2012, PT I, 2012, 7663 : 331 - 338
  • [34] EEG dipole source localization
    Cuffin, BN
    IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1998, 17 (05): : 118 - 122
  • [35] EEG and MEG source localization
    Rampp S.
    Zeitschrift für Epileptologie, 2018, 31 (2): : 109 - 112
  • [36] Trends in EEG source localization
    Koles, ZJ
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1998, 106 (02): : 127 - 137
  • [37] Effects of source space resolution, randomization and averaging in focal EEG source localization: Estimation of forward and inverse errors
    Lahtinen, Joonas
    Rezaei, Atena
    Pursiainen, Sampsa
    JOURNAL OF COMPUTATIONAL AND APPLIED MATHEMATICS, 2024, 448
  • [38] Detecting Large-Scale Brain Networks Using EEG: Impact of Electrode Density, Head Modeling and Source Localization
    Liu, Quanying
    Ganzetti, Marco
    Wenderoth, Nicole
    Mantini, Dante
    FRONTIERS IN NEUROINFORMATICS, 2018, 12
  • [39] FROM EEG SOURCE LOCALIZATION TO SOURCE IMAGING
    SCHERG, M
    ACTA NEUROLOGICA SCANDINAVICA, 1994, 89 : 29 - 30
  • [40] VBM sensitivity to localization and extent of mouse brain lesions: A simulation approach
    Braggio, Delfina
    Barbeito-Andres, Jimena
    Gonzalez, Paula
    Hallgrimsson, Benedikt
    Larrabide, Ignacio
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2020, 196