Ride Through of Wind Turbines With Doubly Fed Induction Generator Under Symmetrical Voltage Dips

被引:267
|
作者
Lopez, Jesus [1 ]
Gubia, Eugenio [1 ]
Olea, Eneko [2 ]
Ruiz, Josu [2 ]
Marroyo, Luis [1 ]
机构
[1] Univ Publ Navarra, Dept Elect & Elect Engn, Pamplona 31006, Spain
[2] Ingeteam Technol, Control Dept Renewable Energy Syst, Zamudio 48170, Spain
关键词
Asynchronous rotating machines; power system faults; wind power generation; SYSTEMS; SPEED;
D O I
10.1109/TIE.2009.2028447
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper deals with the grid fault ride-through capability of doubly fed induction generators. These machines are very sensitive to grid disturbances. To prevent the damages that voltage dips can cause on the converter, most machines are equipped nowadays with a crowbar that short circuits the rotor. However, during the crowbar activation, the rotor converter must be disconnected, hence the power generated with the turbine is no longer controlled. In doing so, the crowbar impedes the wind turbine from carrying out the voltage stabilization required by most new grid codes. This paper proposes a novel control strategy that notably reduces the crowbar activation time. As a result, the control of the turbine might shortly be resumed and the turbine can furthermore supply a reactive power fulfilling the newest grid regulations. Experimental results of a complete system are included, demonstrating the viability of the proposed control.
引用
收藏
页码:4246 / 4254
页数:9
相关论文
共 50 条
  • [31] Analyzing low voltage ride through capability of doubly fed induction generator based wind turbine
    Gebru, Fsaha Mebrahtu
    Khan, Baseem
    Alhelou, Hassan Haes
    Computers and Electrical Engineering, 2020, 86
  • [32] Rotor voltage analysis of doubly fed induction generator under unsymmetrical grid voltage dips
    Zhang, Lu
    Jin, Xinmi
    Zhan, Liangyu
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2012, 36 (14): : 136 - 142
  • [33] Doubly fed induction generator systems for wind turbines
    Müller, S
    Deicke, M
    De Doncker, RW
    IEEE INDUSTRY APPLICATIONS MAGAZINE, 2002, 8 (03) : 26 - 33
  • [34] A fault ride through scheme for doubly fed induction generator wind turbine
    Ling Y.
    Ling, Yu (pleasurely@126.com), 2018, Taylor and Francis Ltd. (15): : 71 - 79
  • [35] Analysis and Control of Doubly Fed Induction Generator for Zero Voltage Ride Through
    Tang, Haiyan
    Chang, Yuanzhu
    Chi, Yongning
    Wang, Bo
    Li, Yan
    Hu, Jiabing
    2016 19TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2016), 2016,
  • [36] A low voltage ride-through of strategy for doubly fed induction generator
    Yu, Lan
    Chen, Guocheng
    Song, Xiaoliang
    Cao, Dapeng
    Wu, Guoxiang
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2010, 25 (09): : 170 - 175
  • [37] High voltage ride-through capability using series grid side converter for doubly fed induction generator based wind turbines
    Boukhris, Youness
    El Makrini, Aboubakr
    El Moussaoui, Hassan
    El Markhi, Hassane
    PROCEEDINGS OF 2015 3RD IEEE INTERNATIONAL RENEWABLE AND SUSTAINABLE ENERGY CONFERENCE (IRSEC'15), 2015, : 766 - 771
  • [38] Proportional-Resonant Control of Doubly-Fed Induction Generator Wind Turbines for Low-Voltage Ride-Through Enhancement
    Yan, Yan
    Wang, Meng
    Song, Zhan-Feng
    Xia, Chang-Liang
    ENERGIES, 2012, 5 (11): : 4758 - 4778
  • [39] Low voltage ride-through control of doubly-fed induction generator wind turbines with a series grid-side converter
    Yao, Jun
    Liao, Yong
    Li, Hui
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2010, 34 (06): : 98 - 103
  • [40] Combined fault ride through scheme based on load-shedding for doubly fed induction generator wind turbines
    Ling Y.
    Jia Q.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2021, 42 (05): : 437 - 442