Ride Through of Wind Turbines With Doubly Fed Induction Generator Under Symmetrical Voltage Dips

被引:267
|
作者
Lopez, Jesus [1 ]
Gubia, Eugenio [1 ]
Olea, Eneko [2 ]
Ruiz, Josu [2 ]
Marroyo, Luis [1 ]
机构
[1] Univ Publ Navarra, Dept Elect & Elect Engn, Pamplona 31006, Spain
[2] Ingeteam Technol, Control Dept Renewable Energy Syst, Zamudio 48170, Spain
关键词
Asynchronous rotating machines; power system faults; wind power generation; SYSTEMS; SPEED;
D O I
10.1109/TIE.2009.2028447
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper deals with the grid fault ride-through capability of doubly fed induction generators. These machines are very sensitive to grid disturbances. To prevent the damages that voltage dips can cause on the converter, most machines are equipped nowadays with a crowbar that short circuits the rotor. However, during the crowbar activation, the rotor converter must be disconnected, hence the power generated with the turbine is no longer controlled. In doing so, the crowbar impedes the wind turbine from carrying out the voltage stabilization required by most new grid codes. This paper proposes a novel control strategy that notably reduces the crowbar activation time. As a result, the control of the turbine might shortly be resumed and the turbine can furthermore supply a reactive power fulfilling the newest grid regulations. Experimental results of a complete system are included, demonstrating the viability of the proposed control.
引用
收藏
页码:4246 / 4254
页数:9
相关论文
共 50 条
  • [21] Improved Control Strategy of Brushless Doubly Fed Induction Generator during Symmetrical Voltage Dips
    Yan, Xiaoming
    Cheng, Ming
    2021 IEEE 12TH ENERGY CONVERSION CONGRESS AND EXPOSITION - ASIA (ECCE ASIA), 2021, : 869 - 874
  • [22] Ride-Through Control of a Doubly Fed Induction Generator Under Unbalanced Voltage Sags
    Gomis-Bellmunt, Oriol
    Junyent-Ferre, Adria
    Sumper, Andreas
    Bergas-Jane, Joan
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2008, 23 (04) : 1036 - 1045
  • [23] An improved fault ride-through strategy for doubly fed induction generator-based wind turbines
    Kasem, A. H.
    El-Saadany, E. F.
    El-Tamaly, H. H.
    Wahab, M. A. A.
    IET RENEWABLE POWER GENERATION, 2008, 2 (04) : 201 - 214
  • [24] Improvement of Fault Ride Through Capability of Doubly-Fed Induction Generator Wind Turbines with Hysteresis Controller
    Ling, Yu
    WIND ENGINEERING, 2014, 38 (06) : 659 - 672
  • [25] Understanding the Doubly Fed Induction Generator During Voltage Dips
    Marques, G. D.
    Sousa, Duarte M.
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2012, 27 (02) : 421 - 431
  • [26] Voltage Sag Ride Through using Adaptive Controller for Doubly Fed Induction Generator Wind Farms
    Amuthan, N.
    Subburaj, P.
    2012 ANNUAL IEEE INDIA CONFERENCE (INDICON), 2012, : 456 - 460
  • [27] Control Method of the Low Voltage Ride Through in the Doubly-Fed Induction Generator Wind Turbine
    Liu, Fang
    Mei, Mingwei
    Pan, Juntao
    2013 32ND CHINESE CONTROL CONFERENCE (CCC), 2013, : 7600 - 7605
  • [28] Analyzing low voltage ride through capability of doubly fed induction generator based wind turbine
    Gebru, Fsaha Mebrahtu
    Khan, Baseem
    Alhelou, Hassan Haes
    COMPUTERS & ELECTRICAL ENGINEERING, 2020, 86
  • [29] Study of low voltage ride through performance for wind power generation with doubly fed induction generator
    Hirawata, Ryoya
    Kai, Takaaki
    IEEJ Transactions on Power and Energy, 2012, 132 (04) : 301 - 308
  • [30] Research on Low Voltage Ride Through of Doubly-fed Induction Generator wind power System
    Ren, Yongfeng
    Xu, Hongyan
    Li, Jianlin
    Hu, Shuju
    2008 INTERNATIONAL SYMPOSIUM ON INTELLIGENT INFORMATION TECHNOLOGY APPLICATION WORKSHOP: IITA 2008 WORKSHOPS, PROCEEDINGS, 2008, : 1117 - +