Ride Through of Wind Turbines With Doubly Fed Induction Generator Under Symmetrical Voltage Dips

被引:267
|
作者
Lopez, Jesus [1 ]
Gubia, Eugenio [1 ]
Olea, Eneko [2 ]
Ruiz, Josu [2 ]
Marroyo, Luis [1 ]
机构
[1] Univ Publ Navarra, Dept Elect & Elect Engn, Pamplona 31006, Spain
[2] Ingeteam Technol, Control Dept Renewable Energy Syst, Zamudio 48170, Spain
关键词
Asynchronous rotating machines; power system faults; wind power generation; SYSTEMS; SPEED;
D O I
10.1109/TIE.2009.2028447
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper deals with the grid fault ride-through capability of doubly fed induction generators. These machines are very sensitive to grid disturbances. To prevent the damages that voltage dips can cause on the converter, most machines are equipped nowadays with a crowbar that short circuits the rotor. However, during the crowbar activation, the rotor converter must be disconnected, hence the power generated with the turbine is no longer controlled. In doing so, the crowbar impedes the wind turbine from carrying out the voltage stabilization required by most new grid codes. This paper proposes a novel control strategy that notably reduces the crowbar activation time. As a result, the control of the turbine might shortly be resumed and the turbine can furthermore supply a reactive power fulfilling the newest grid regulations. Experimental results of a complete system are included, demonstrating the viability of the proposed control.
引用
收藏
页码:4246 / 4254
页数:9
相关论文
共 50 条
  • [1] Crowbarless Fault Ride-Through of the Brushless Doubly Fed Induction Generator in a Wind Turbine Under Symmetrical Voltage Dips
    Long, Teng
    Shao, Shiyi
    Malliband, Paul
    Abdi, Ehsan
    McMahon, Richard A.
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (07) : 2833 - 2841
  • [2] Wind turbines based on doubly fed induction generator under asymmetrical voltage dips
    Lopez, Jesus
    Gubia, Eugenio
    Sanchis, Pablo
    Roboam, Xavier
    Marroyo, Luis
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2008, 23 (01) : 321 - 330
  • [3] Control of Doubly Fed Induction Generator under Symmetrical Voltage dips
    Lopez, Jesus
    Sanchis, Pablo
    Gubia, Eugenio
    Ursua, Alfredo
    Marroyo, Luis
    Roboam, Xavier
    2008 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, VOLS 1-5, 2008, : 1574 - 1580
  • [4] Low voltage ride through operation and control of doubly fed induction generator wind turbines
    Hu, Jiabing
    He, Yikang
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2008, 32 (02): : 49 - 52
  • [5] Providing Ride-Through Capability to a Doubly Fed Induction Generator Under Unbalanced Voltage Dips
    Santos-Martin, David
    Luis Rodriguez-Amenedo, Jose
    Arnaltes, Santiago
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (07) : 1747 - 1757
  • [6] The fault ride through technologies for doubly fed induction generator wind turbines
    Ling, Yu
    WIND ENGINEERING, 2016, 40 (01) : 31 - 49
  • [7] Dynamic Behavior of Doubly Fed Induction Generator Wind Turbines under Three-phase Voltage Dips
    Peng, Ling
    Li, Yongdong
    Francois, Bruno
    2009 IEEE 6TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-4, 2009, : 1376 - +
  • [8] The impact of voltage dips to low-voltage-ride-through capacity of doubly fed induction generator based wind turbine
    Chen, Cheng
    Bagheri, Azam
    Bollen, Math H. J.
    Bongiorno, Massimo
    2019 IEEE MILAN POWERTECH, 2019,
  • [9] Improvement of the Low-voltage Ride-through Capability of Doubly Fed Induction Generator Wind Turbines
    Ling, Yu
    Dou, Zhenlan
    Gao, Qiang
    Cai, Xu
    WIND ENGINEERING, 2012, 36 (05) : 535 - 551
  • [10] Improved fault ride through strategy for doubly fed induction generator based wind turbines under both symmetrical and asymmetrical grid faults
    Mohammadi, Jafar
    Afsharnia, Saeed
    Vaez-Zadeh, Sadegh
    Farhangi, Shahrokh
    IET RENEWABLE POWER GENERATION, 2016, 10 (08) : 1114 - 1122