Robust three-dimensional registration on optical coherence tomography angiography for speckle reduction and visualization

被引:15
|
作者
Cheng, Yuxuan [1 ]
Chu, Zhongdi [1 ]
Wang, Ruikang K. [1 ,2 ]
机构
[1] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
[2] Univ Washington, Dept Ophthalmol, Seattle, WA 98195 USA
基金
美国国家卫生研究院;
关键词
Optical coherence tomography (OCT); optical coherence tomography angiography (OCTA); motion artifact; speckle noise; averaging; 3D registration; CHORIOCAPILLARIS FLOW DEFICITS; NEOVASCULARIZATION; OPTIMIZATION; CONTRAST; DOMAIN; SPEED;
D O I
10.21037/qims-20-751
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: In the clinical applications of optical coherence tomography angiography (OCTA), the repeated scanning and averaging method can provide better contrast with reduced speckle noises in the final results, which are useful for visualizing and quantifying vascular components with high accuracy, reproducibility, and reliability. However, the inevitable patient motion presents a challenge to this method. The objective of this study is to meet this challenge by introducing a 3D registration method to register optical coherence tomography (OCT)/OCTA scans for precise volume averaging of multiple scans to improve the signal-to-noise ratio (SNR) and increase quantification accuracy. Methods: The proposed method utilized both rigid affine transformation and non-rigid B-spline transformation in which their parameters were optimized and calculated by the average stochastic gradient descent on OCT structural images. In addition, we also introduced a multi-level resolution approach to further improve the robustness and computational speed of our proposed method. The imaging performance was tested on in vivo imaging of human skin and eye and assessed by SNR, peak signal-to-noise ratio (PSNR) and normalized correlation coefficient (NCC). Results: Five subjects were enrolled in this study for obtaining in vivo images of skin and retina. The proposed registration and averaging method provided substantial improvements of the imaging performance in terms of vessel connectivity and signal to noise ratio. The increase of repeated volume numbers in the averaging improves all the metrics assessed, i.e., SNR, PSNR and NCC. An improvement of the SNR from 10 to 40 dB after 10 repeated volumetric averaging was achieved. Conclusions: The proposed 3D registration and averaging method is effective in reducing speckle noises and suppressing motion artifacts, thereby improving SNR, PSNR and NCC metrics for final averaged images. It is expected that the proposed algorithm would be practically useful in better visualization and more reliable quantification of in vivo OCT and OCTA data, which would be beneficial to OCT clinical applications.
引用
收藏
页码:879 / 894
页数:16
相关论文
共 50 条
  • [41] Tail artifacts removal of three-dimensional optical coherence tomography angiography with common parts extraction method
    Zhang, Wenxin
    He, Bin
    Wu, Yangkang
    Tao, Yuxiu
    Zhu, Fu
    Cai, Wenchao
    Liu, Ning
    Zhao, Qiang
    Xue, Ping
    JOURNAL OF BIOPHOTONICS, 2022, 15 (11)
  • [42] Comparison of Stent Expansion Assessment by Three-Dimensional Quantitative Coronary Angiography Versus Optical Coherence Tomography
    Vergara-Martel, Armando
    Pereira, Gabriel Tensol Rodrigues
    Dallan, Luis Augusto Palma
    Pizzato, Patricia
    Zago, Elder
    Zimin, Vlad
    Jia, Dean
    Elbey, Mehmet
    Samdani, Jawwad Abdul
    Attizzani, Guilherme
    Bezerra, Hiram
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (04) : S2 - S3
  • [43] Optical coherence tomography for three-dimensional imaging of skin features
    Lenderink, E
    OPTICAL AND IMAGING TECHNIQUES FOR BIOMONITORING IV, PROCEEDINGS OF, 1999, 3567 : 70 - 77
  • [44] Three-dimensional tracker for spectral domain optical coherence tomography
    Hammer, Daniel X.
    Iftimia, Nicusor V.
    Bigelow, Chad E.
    Ustun, Teoman E.
    Bloom, Benjamin
    Ferguson, R. Daniel
    Milner, Thomas E.
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE XI, 2007, 6429
  • [45] Integrated three-dimensional scanner for endoscopic optical coherence tomography
    Aljasem, Khaled
    Froehly, Luc
    Zappe, Hans
    Seifert, Andreas
    MICRO-OPTICS 2010, 2010, 7716
  • [46] Intraoperative assessment of microsurgery with three-dimensional optical coherence tomography
    Boppart, SA
    Bouma, BE
    Pitris, C
    Southern, JF
    Brezinski, ME
    Fujimoto, JG
    RADIOLOGY, 1998, 208 (01) : 81 - 86
  • [47] Three-dimensional Imaging of Ureter With Endoscopic Optical Coherence Tomography
    Wang, Hui
    Kang, Wei
    Zhu, Hui
    MacLennan, Gregory
    Rollins, Andrew M.
    UROLOGY, 2011, 77 (05) : 1254 - 1258
  • [48] Three-dimensional optical coherence tomography of granular corneal dystrophy
    Miura, Masahiro
    Mori, Hideki
    Watanabe, Yuji
    Usui, Masahiko
    Kawana, Keisuke
    Oshika, Tetsuro
    Yatagai, Toyohiko
    Yasuno, Yoshiaki
    CORNEA, 2007, 26 (03) : 373 - 374
  • [49] Three-dimensional color camera based on optical coherence tomography
    Cen, Zhentao
    Zeng, Kun
    Liu, Biwang
    Huang, Liyuan
    He, Zhennan
    Xiong, Honglian
    Han, Dingan
    Zeng, Yaguang
    OPTICS COMMUNICATIONS, 2021, 478
  • [50] Three-dimensional Reconstruction of Optical Coherence Tomography Images of Esophagus
    Nao, Sihan
    Zhang, Miao
    Wang, Lirong
    Xu, Yongjin
    Chen, Xiaohe
    PROCEEDINGS OF 2019 4TH INTERNATIONAL CONFERENCE ON BIOMEDICAL SIGNAL AND IMAGE PROCESSING (ICBIP 2019), 2019, : 77 - 82