Impact of water quality on setting of irreversible hydrocolloid impression materials

被引:5
|
作者
Bradna, Pavel
Cerna, Darina
机构
[1] Charles Univ, Fac Med 1, Inst Dent Res, Prague, Czech Republic
[2] Gen Univ Hosp, Prague, Czech Republic
[3] Spofa Dent AS, Dept Res & Dev, Prague, Czech Republic
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2006年 / 96卷 / 06期
关键词
D O I
10.1016/j.prosdent.2006.10.006
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Setting of irreversible hydrocolloid impression materials is based on the ionic reaction between carboxylic groups and calcium ions and may, therefore, be affected by ionic species present in the mixing water. The impact of this phenomenon on the clinical performance of these materials has not been well documented. Purpose. The purpose of this study was to compare the setting behavior of irreversible hydrocolloid impression materials when mixed with tap and distilled water, and to determine the impact of typical cations present in tap water and their concentrations on the setting process. Material and methods. Six brands of irreversible hydrocolloid impression materials (Kromopan 100, Xantalgin Select FS, Alginoplast, Elastic Plus, Ypeen, and Ypeen Premium) were mixed with tap and distilled water (control) according to manufacturers' recommendations. Elastic Plus was also mixed with aqueous solutions containing various concentrations of NaCl, CaCl2, and AlCl3 to determine the role of typical cations on setting. Using a controlled shear stress oscillatory rheometer, time changes of storage (G') and loss (G") moduli during setting were measured at 23 degrees C and used to determine the working and setting times and rigidity of set impression materials. The sample size (n=3) for each material/mixing system was increased to 8 to increase reliability of measurements in systems where the effect of mixing water was low or variance of results was high. The data were analyzed (alpha=.05) using a t test (tap water), a 1-way ANOVA, a Tukey post hoc test (shear stress), and a nested ANOVA and Fisher Least Significant Difference post hoc analysis (cation and cation concentration). Results. Statistical analysis showed significant (P<.001) acceleration in the setting rate for Kromopan 100, the working time of which was shorter with tap water by 23.4 seconds and the setting time, by 32.8 seconds. Similar significant reductions (in seconds) in both working and setting times, respectively, were found with Xantalgin Select FS (12.0, P<.001 and 23.6, P<.002), Alginoplast (24.3, P<.001 and 44.7, P<.005), and Elastic Plus (23.0, P<.001 and 22.0, P<.002), when compared with the same materials mixed with distilled water. At the same time, the rigidity of the set impression materials mixed with tap water increased by approximately 10%. With Ypeen Premium, the setting time decreased significantly by 20.0 seconds (P<.001) with tap water, while the working time and rigidity did not change. The setting behavior of Ypeen was not significantly affected by water quality. Acceleration of the setting reactions and increase in impression rigidity depended (P<.001) primarily on concentration and valency of cations present in mixing water. Conclusion. Setting of irreversible hydrocolloid impression materials can be significantly accelerated when tap water with high water hardness is used for mixing or when the mixing water contains higher concentrations of cations such as Na+, Ca2+, and Al3+.
引用
收藏
页码:443 / 448
页数:6
相关论文
共 50 条
  • [41] An evaluation of antimicrobial potential of irreversible hydrocolloid impression material incorporated with chitosan
    Manikyamba, Yenumula J. B.
    Raju, A. V. Rama
    Sajjan, M. C. Suresh
    Bhupathi, P. Arun
    Rao, D. Bheemalingeswara
    Raju, Jampana V. V. S. N.
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2020, 20 (03): : 297 - 303
  • [42] Management of a patient's gag reflex in making an irreversible hydrocolloid impression
    Hattab, FN
    Al-Omari, MAO
    Al-Duwayri, ZN
    JOURNAL OF PROSTHETIC DENTISTRY, 1999, 81 (03): : 369 - 369
  • [43] THE EFFECT OF POWDER WATER RATIO OF IRREVERSIBLE HYDROCOLLOID ON THE BOND STRENGTH OF IRREVERSIBLE HYDROCOLLOID AND AGAR COMBINATIONS
    LEWINSTEIN, I
    CRAIG, RG
    JOURNAL OF PROSTHETIC DENTISTRY, 1989, 62 (04): : 412 - 416
  • [44] Comparing the accuracy of reversible hydrocolloid and elastomeric impression materials
    Federick, DR
    Caputo, A
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1997, 128 (02): : 183 - 188
  • [45] COMPARATIVE ACCURACY OF REVERSIBLE HYDROCOLLOID AND ELASTOMERIC IMPRESSION MATERIALS
    FEDERICK, D
    CAPUTO, AA
    JOURNAL OF DENTAL RESEARCH, 1995, 74 : 472 - 472
  • [46] EFFECT OF HYDROCOLLOID IMPRESSION MATERIALS ON SURFACE OF DENTAL STONE
    SMITH, DC
    FAIRHURST, CW
    JOURNAL OF DENTAL RESEARCH, 1962, 41 (05) : 1103 - &
  • [47] Dermal and mucosal reactions to an antimicrobial irreversible hydrocolloid impression material: A clinical report
    Baker, PS
    Plummer, KD
    Parr, GR
    Parker, MH
    JOURNAL OF PROSTHETIC DENTISTRY, 2006, 95 (03): : 190 - 193
  • [48] BACTERIAL-CONTAMINATION IN IRREVERSIBLE HYDROCOLLOID IMPRESSION MATERIAL AND GINGIVAL RETRACTION CORD
    RICE, CD
    DYKSTRA, MA
    GIER, RE
    JOURNAL OF PROSTHETIC DENTISTRY, 1991, 65 (04): : 496 - 499
  • [49] BOND STRENGTH AND ACCURACY OF COMBINED REVERSIBLE-IRREVERSIBLE HYDROCOLLOID IMPRESSION SYSTEMS
    LEPE, X
    SANDRIK, JL
    LAND, MF
    JOURNAL OF PROSTHETIC DENTISTRY, 1992, 67 (05): : 621 - 627
  • [50] A Promising Potential of Brown Algae Sargassum polycystum as Irreversible Hydrocolloid Impression Material
    Hamrun, Nurlindah
    Talib, Bahruddin
    Ruslin, Muhammad
    Pangeran, Hasminar
    Hatta, Mochammad
    Marlina, Erni
    Yusuf, Andi Sitti Hajrah
    Saito, Takashi
    Ou, Keng-Liang
    MARINE DRUGS, 2022, 20 (01)