Measurement of patient dose in ultraviolet therapy using a phantom

被引:7
|
作者
Fulljames, CA [1 ]
Welsh, AD
机构
[1] Gloucestershire Royal Hosp, Dept Med Phys, Gloucester GL1 3NN, England
[2] Cheltenham Gen Hosp, Dept Med Phys, Cheltenham GL53 7AN, Glos, England
关键词
dosimetry; phantom; ultraviolet;
D O I
10.1046/j.1365-2133.2000.03421.x
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
A phantom was developed as a reproducible means of measuring the irradiance in an occupied ultraviolet cabin, by placing the phantom, or replica person, in the cabin, obviating the need for human exposure. The contributions to the patient irradiance measured in the cabin were investigated, looking in particular at the effect of the reflectors, Radiation undergoing single reflection was seen to contribute to a greater extent than multiple reflections, Placing an object in the cabin reduces the measured irradiance due to the blocking of multiple reflections, but variation in the exact shape and size of the object has less effect, which is useful as patients are of all shapes and sizes and a representative phantom was to be developed. The phantom was made of expanded polystyrene blocks with an embedded probe. Measurements were made to verify the equivalence of human and phantom cabin occupancy. It was found that the irradiance measured with the phantom in the cabin lies within the values measured with human occupancy.
引用
收藏
页码:748 / 751
页数:4
相关论文
共 50 条
  • [31] On a New Approach to Reconstruct the Patient Dose From Phantom Measurements
    Bangtsson, E.
    de Vries, W.
    MEDICAL PHYSICS, 2016, 43 (06) : 3370 - 3371
  • [32] Ultraviolet radiation therapy and UVR dose models
    Grimes, David Robert
    MEDICAL PHYSICS, 2015, 42 (01) : 440 - 455
  • [33] A phantom for effective dose measurement: Organ dose distribution assessment based on a numerical approach
    Furstoss, C.
    Menard, S.
    Clairand, I.
    Chau, Q.
    RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 180 - 184
  • [34] DOSE MEASUREMENT IN PUVA THERAPY
    DEBERSAQUES, J
    DERMATOLOGICA, 1979, 159 (02): : 176 - 179
  • [35] Improved precision of syndesmophyte measurement for the evaluation of ankylosing spondylitis using CT: a phantom and patient study
    Tan, Sovira
    Yao, Jianhua
    Yao, Lawrence
    Ward, Michael M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (14): : 4683 - 4704
  • [36] Measurement of Patient Skin Dose in Vertebroplasty Using Radiochromic Dosimetry Film
    D'Ercole, Loredana
    Azzaretti, Andrea
    Thyrion, Federico Zappoli
    Bocchiola, Milena
    Di Maria, Federico
    SPINE, 2010, 35 (13) : 1304 - 1306
  • [37] Measurement of urinary radiation dose of PET patient by using Compton camera
    Kano, D.
    Enomoto, R.
    Hosokawa, S.
    Wakamatsu, R.
    Watanabe, T.
    Nakagami, Y.
    Yamaguchi, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S470 - S471
  • [38] Investigation on the effect of sharp phantom edges on point dose measurement during patient-specific dosimetry with Rapid Arc
    Kinhikar, R. A.
    Pandey, V. P.
    Jose, Rojas K.
    Mahantshetty, U.
    Dhote, D. S.
    Deshpande, D. D.
    Shrivastava, S. K.
    JOURNAL OF MEDICAL PHYSICS, 2013, 38 (03) : 139 - 142
  • [39] Measurement of Entrance Surface Dose on an Anthropomorphic Thorax Phantom Using a Miniature Fiber-Optic Dosimeter
    Yoo, Wook Jae
    Shin, Sang Hun
    Jeon, Dayeong
    Hong, Seunghan
    Sim, Hyeok In
    Kim, Seon Geun
    Jang, Kyoung Won
    Cho, Seunghyun
    Youn, Won Sik
    Lee, Bongsoo
    SENSORS, 2014, 14 (04) : 6305 - 6316
  • [40] PATIENT DOSE MEASUREMENT AND DOSE REDUCTION IN CHEST RADIOGRAPHY
    Milatovic, Aleksandra A.
    Spasic Jokic, Vesna M.
    Jovanovic, Slobodan I.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2014, 29 (03): : 220 - 225