Measurement of patient dose in ultraviolet therapy using a phantom

被引:7
|
作者
Fulljames, CA [1 ]
Welsh, AD
机构
[1] Gloucestershire Royal Hosp, Dept Med Phys, Gloucester GL1 3NN, England
[2] Cheltenham Gen Hosp, Dept Med Phys, Cheltenham GL53 7AN, Glos, England
关键词
dosimetry; phantom; ultraviolet;
D O I
10.1046/j.1365-2133.2000.03421.x
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
A phantom was developed as a reproducible means of measuring the irradiance in an occupied ultraviolet cabin, by placing the phantom, or replica person, in the cabin, obviating the need for human exposure. The contributions to the patient irradiance measured in the cabin were investigated, looking in particular at the effect of the reflectors, Radiation undergoing single reflection was seen to contribute to a greater extent than multiple reflections, Placing an object in the cabin reduces the measured irradiance due to the blocking of multiple reflections, but variation in the exact shape and size of the object has less effect, which is useful as patients are of all shapes and sizes and a representative phantom was to be developed. The phantom was made of expanded polystyrene blocks with an embedded probe. Measurements were made to verify the equivalence of human and phantom cabin occupancy. It was found that the irradiance measured with the phantom in the cabin lies within the values measured with human occupancy.
引用
收藏
页码:748 / 751
页数:4
相关论文
共 50 条
  • [21] In-phantom neutron dose measurement using Gafchromic film dosimeter for QA of BNCT beams
    Hsiao, Ming-Chen
    Jiang, Shiang-Huei
    APPLIED RADIATION AND ISOTOPES, 2019, 143 : 79 - 86
  • [22] Monte carlo calculation of radiation dose in CT examinations using phantom and patient tomographic models
    Salvadó, M
    López, M
    Morant, JJ
    Calzado, A
    RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) : 364 - 368
  • [23] Evaluation of absorbed dose in respiratory gated radiotherapy using a phantom system that simulates patient respiration
    Oyama, M
    Shimbo, M
    Inoue, K
    Tohyarna, N
    Goka, T
    Nishimura, H
    Ogino, T
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S511 - S511
  • [24] HIGH RESOLUTION DOSE-DISTRIBUTION MEASUREMENT AT PHANTOM INTERFACES
    MCLAUGHLIN, WL
    PHYSICS IN MEDICINE AND BIOLOGY, 1966, 11 (01): : 161 - +
  • [25] In phantom measurement of megavoltage photon dose in free space (WIP)
    Rakowski, J
    Yudelev, M
    MEDICAL PHYSICS, 2003, 30 (06) : 1481 - 1481
  • [26] EFFECTIVE DOSE MEASUREMENT AT WORKPLACES WITHIN AN INSTRUMENTED ANTHROPOMORPHIC PHANTOM
    Villagrasa, C.
    Darreon, J.
    Martin-Burtat, N.
    Clairand, I.
    Colin, J.
    Fontbonne, J. M.
    RADIATION PROTECTION DOSIMETRY, 2011, 144 (1-4) : 640 - 644
  • [27] The Effect of Reducing CT Dose on Proton Therapy Dose Calculation - Phantom Study
    Elhamiasl, M.
    Salvo, K.
    Sterpin, E.
    Nuyts, J.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1512 - S1513
  • [28] ArcCheck Hypothesis Testing: Is Dose Error in a Phantom Applicable to the Patient?
    Barbiere, J.
    Ndlovu, A.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [29] Phantom-and patient-specific dose calculations for CT
    Schmidt, B
    Kalender, WA
    RADIOLOGY, 2002, 225 : 592 - 592
  • [30] Pilot study of patient and phantom breast dose measurements in Bulgaria
    Avramova-Cholakova, Simona
    Vassileva, Jenia
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2008, 14 (01): : 21 - 32