Pole Mounted Distribution Transformers Insulation Condition Assessment

被引:0
|
作者
Noirhomme, B. [1 ]
Jalbert, J. [1 ]
Lessard, M. -C. [1 ]
Brochu, F. [1 ]
Hachichi, S. [2 ]
机构
[1] Hydroquebec IREQ, Varennes, PQ, Canada
[2] Hydro Quebec Distribut, Evolut Reseau, Montreal, PQ, Canada
关键词
Overhead transformers; insulation; gas analysis; refurbishment; service age; degree of polymerization (DPv);
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Hydro-Quebec (HQ) Distribution grid has close to 600,000 overhead distribution transformers in service. On average, every year 10,000 units are taken out of service for various reasons such as failures, replacement due to load rise and network reconfiguration. In 2006/07, HQ Distribution started a refurbishment program to give them a second life on the distribution grid. It is neither acceptable nor efficient to proceed with the refurbishment of a transformer having a degraded solid insulation and consequently an expected low residual life. In 2010, a project was started to assess the condition of the insulation of different service-aged transformers. 121 distributions transformers were randomly sampled from the units sent for refurbishment. Samples were taken from the following manufacturing year ranges: before 1985, 1985-1989, 1990- 1994, 1995-1999, 2000-2004 and 2005-2010. In this evaluation, oil samples were taken from each transformer to assess oil quality and transformer condition. Paper sampled from the coils, were also taken in specific cases amongst the faulty transformers. The preliminary conclusions that can be drawn from this study are that transformers manufactured after 1985 do not seem to experience any major aging with respect to their insulation. It therefore appears that if no faults are present, the transformers should be refurbished since the insulation basically in a good condition.
引用
收藏
页码:239 / 243
页数:5
相关论文
共 50 条
  • [41] Practical experiences of using FDS for determining the insulation condition of instrument transformers
    Podkoritnik, Simon
    Oseneic, Peter
    Zupanc, Boris
    Zima, Nejc
    Praznik, Jure
    Judnic, Rok
    2024 INTERNATIONAL CONFERENCE ON DIAGNOSTICS IN ELECTRICAL ENGINEERING, DIAGNOSTIKA 2024, 2024, : 136 - 140
  • [42] Assessment of power transformer insulation condition
    Sokolov, V
    Bulgakova, V
    Berler, Z
    ELECTRICAL INSULATION CONFERENCE AND ELECTRICAL MANUFACTURING & COIL WINDING CONFERENCE, PROCEEDINGS, 2001, : 605 - 613
  • [43] A New Approach for Estimating Insulation Condition of Field Transformers Using FRA
    Mohd Yousof, Mohd Fairouz
    Al-Ameri, Salem
    Ahmad, Hussein
    Illias, Hazlee Azil
    Arshad, Syahrun Nizam Md
    ADVANCES IN ELECTRICAL AND COMPUTER ENGINEERING, 2020, 20 (01) : 35 - 42
  • [44] Investigations into effective methods for assessing the condition of insulation in aged power transformers
    Darveniza, M
    Saha, TK
    Hill, DJT
    IEEE TRANSACTIONS ON POWER DELIVERY, 1998, 13 (04) : 1214 - 1223
  • [45] Review of modern diagnostic techniques for assessing insulation condition in aged transformers
    Saha, TK
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2003, 10 (05) : 903 - 917
  • [46] Review of condition assessment of power transformers in service
    Wang, M
    Vandermaar, AJ
    Srivastava, KD
    IEEE ELECTRICAL INSULATION MAGAZINE, 2002, 18 (06) : 12 - 25
  • [47] Application of biodegradable fluids as liquid insulation for distribution and power transformers
    Garcia, Belen
    Ortiz, Alfredo
    Renedo, Carlos
    Carlos Burgos, Juan
    Garcia Gomez, Diego
    Perez Rosa, Daniel
    2020 20TH IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2020 4TH IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC/I&CPS EUROPE), 2020,
  • [48] Analysis of the Key Problem About Insulation Condition Assessment of Oil-paper in Power Transformers Based on Partial Discharge
    Li Q.
    Li S.
    Si W.
    Wang G.
    Wang B.
    Liu B.
    Li, Simeng (lisimeng251106@163.com), 1600, Science Press (43): : 2558 - 2565
  • [49] Measurements of the insulation resistance in distribution transformers of a 20 kV network
    Koufakis, E. I.
    Karagiannopoulos, C. G.
    Bourkas, P. D.
    PROCEEDINGS OF THE SIXTH IASTED INTERNATIONAL CONFERENCE ON EUROPEAN POWER AND ENERGY SYSTEMS, 2006, : 90 - +
  • [50] Assessment of the Health Condition of Oil-Immersed Transformers Using Logistic Regression and Poisson Distribution
    Areffin, Sultanul
    Bhuiyan, Mohammed Imamul Hasan
    Chowdhury, Aongti
    2017 3RD INTERNATIONAL CONFERENCE ON ELECTRICAL INFORMATION AND COMMUNICATION TECHNOLOGY (EICT 2017), 2017,