Pole Mounted Distribution Transformers Insulation Condition Assessment

被引:0
|
作者
Noirhomme, B. [1 ]
Jalbert, J. [1 ]
Lessard, M. -C. [1 ]
Brochu, F. [1 ]
Hachichi, S. [2 ]
机构
[1] Hydroquebec IREQ, Varennes, PQ, Canada
[2] Hydro Quebec Distribut, Evolut Reseau, Montreal, PQ, Canada
关键词
Overhead transformers; insulation; gas analysis; refurbishment; service age; degree of polymerization (DPv);
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Hydro-Quebec (HQ) Distribution grid has close to 600,000 overhead distribution transformers in service. On average, every year 10,000 units are taken out of service for various reasons such as failures, replacement due to load rise and network reconfiguration. In 2006/07, HQ Distribution started a refurbishment program to give them a second life on the distribution grid. It is neither acceptable nor efficient to proceed with the refurbishment of a transformer having a degraded solid insulation and consequently an expected low residual life. In 2010, a project was started to assess the condition of the insulation of different service-aged transformers. 121 distributions transformers were randomly sampled from the units sent for refurbishment. Samples were taken from the following manufacturing year ranges: before 1985, 1985-1989, 1990- 1994, 1995-1999, 2000-2004 and 2005-2010. In this evaluation, oil samples were taken from each transformer to assess oil quality and transformer condition. Paper sampled from the coils, were also taken in specific cases amongst the faulty transformers. The preliminary conclusions that can be drawn from this study are that transformers manufactured after 1985 do not seem to experience any major aging with respect to their insulation. It therefore appears that if no faults are present, the transformers should be refurbished since the insulation basically in a good condition.
引用
收藏
页码:239 / 243
页数:5
相关论文
共 50 条
  • [21] Evaluation and application of oil-immersed zinc oxide elements enclosed in pole-mounted distribution transformers
    Uchida, S
    Araki, K
    Kaku, I
    Sakuraba, Y
    Takeshina, T
    Shirakawa, S
    ELECTRICAL ENGINEERING IN JAPAN, 1997, 121 (02) : 37 - 46
  • [22] Experimental determination of the effects of steep front - short duration surges on 25 kVA pole mounted distribution transformers
    Eichler, Charles H.
    Legro, James R.
    Barnes, Paul R.
    IEEE Transactions on Power Delivery, 1992, v (0n) : 1103 - 1110
  • [23] Research on insulation condition monitoring system for power transformers
    Ren, Shuangzan
    Yang, Xu
    Yang, Wenhu
    Xi, Baofeng
    Cao, Xiaolong
    PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 1005 - 1007
  • [24] Condition Assessment of Power Transformers
    Fuhr, Jitka
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 9 - 17
  • [25] Investigation of Distribution Transformers Vibrations in Terms of Core and Winding Condition Assessment
    Gielniak, Jaroslaw
    Czerniak, Magdalena
    ENERGIES, 2022, 15 (01)
  • [26] Condition assessment of the power transformers
    Doncuk, Jan
    Mentlik, Vaclav
    Velek, Jiri
    PROCEEDINGS OF THE 14TH INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRIC POWER ENGINEERING 2013, 2013, : 497 - 501
  • [27] Condition Assessment of Power Transformers
    Vandermaar, A. J.
    2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 3028 - 3032
  • [28] Improving the insulation condition of power transformers with an innovative paper insulation demoisturing procedure
    Wasserberg, V
    Borsi, H
    Gockenbach, E
    PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 & 2, 2000, : 85 - 88
  • [29] Impact of the condition of oil on the polarisation based diagnostics for assessing the condition of transformers insulation
    Saha, TK
    Purkait, P
    2005 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS, 1-3, 2005, : 1881 - 1886
  • [30] PD knowledge rules for insulation condition assessment of distribution power cables
    Gulski, E
    Smit, JJ
    Wester, FJ
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2005, 12 (02) : 223 - 239