A comparison of manual counting of rabbit reticulocytes with ADVIA 2120i analyzer counting

被引:2
|
作者
Kaufhold, Annemarie E. [1 ,3 ]
Hirschberger, Johannes [1 ]
Reese, Sven [2 ]
Foerster, Gesine [3 ]
Hein, Jutta [3 ]
机构
[1] Ludwig Maximilians Univ Munchen, Ctr Clin Vet Med, Clin Small Anim Med, Munich, Germany
[2] Ludwig Maximilians Univ Munchen, Ctr Clin Vet Med, Dept Anat Histol & Embryol, Munich, Germany
[3] Synlab Vet Lab, Augsburg, Germany
关键词
EDTA; hematology; Li-heparin; method comparison; rabbits; reticulocyte maturation; HEMATOLOGY ANALYZER; VALUES; CATS; DOGS;
D O I
10.1177/1040638717750428
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
We compared manual counting of reticulocytes in rabbits with automatic counting using an ADVIA 2120i analyzer. Reproducibility and the influence of different anticoagulants (EDTA and Li-heparin) were also examined. Blood samples of 331 rabbits (method comparison, n = 289; reproducibility, n = 33; comparison of anticoagulants, n = 9) were tested. The reticulocyte numbers of each specimen were manually determined twice for method comparison. Passing-Bablok regressions, Bland-Altman plots, and the coefficient of variation (CV) were used to evaluate statistical significance. Good correlation (rs = 0.81) was observed between manual reticulocyte counting (groups 1-4) and the ADVIA 2120i. Quantification with the ADVIA 2120i was reproducible for relative reticulocyte numbers (EDTA, CV = 4.24%; Li-heparin, CV = 3.63%) and absolute reticulocyte numbers (EDTA, CV = 5.64%; Li-heparin, CV = 3.81%). The absolute and relative reticulocyte numbers were significantly higher in Li-heparin samples than in EDTA samples (absolute, p = 0.009; relative, p = 0.016). The ADVIA 2120i is suitable for counting reticulocytes in rabbit blood samples, but reticulocyte numbers are higher by manual counting than by ADVIA 2120i counting. Therefore, microscopic confirmation of quantifications is recommended when high numbers of reticulocytes are observed. The anticoagulant of choice is EDTA.
引用
收藏
页码:337 / 341
页数:5
相关论文
共 50 条
  • [31] FUNDAMENTAL INVESTIGATION OF NEUTROPHIL EXTRACELLULAR TRAPS (NETS) DETECTION IN PLATELET ABSORPTION CYTOGRAM USING ADVIA 2120I
    Yamaguchi, Wataru
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2023, 45 : 131 - 131
  • [32] COMPARATIVE STUDY OF THE BLAST FLAG PROVIDED BY MINDRAY BC 6800 PLUS AND ADVIA 2120I HEMATOLOGY ANALYZERS
    Molina, Angel
    Julian, Judit
    Laguna, Javier
    Rodriguez, Maria
    Casanova, Alexandra
    Merino, Anna
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2023, 45 : 80 - 81
  • [33] Automated counting of phytoplankton by pattern recognition: a comparison with a manual counting method
    Embleton, KV
    Gibson, CE
    Heaney, SI
    JOURNAL OF PLANKTON RESEARCH, 2003, 25 (06) : 669 - 681
  • [34] ADVIA 2120i血细胞分析仪计数血小板假性减少二例
    朱文元
    杨洪芬
    赵果元
    胡峻梅
    崔淼淼
    海南医学, 2015, 26 (06) : 922 - 924
  • [35] Differential white blood cell counts in rabbits: a comparison of the Advia 2120 and a manual method
    Oikonomidis, Ioannis L.
    Milne, Elspeth
    Piccinelli, Chiara
    JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2021, 33 (04) : 670 - 676
  • [36] COMPARATIVE ASSESSMENT OF THE MAIN PARAMETERS OF THE HEMOGRAM BETWEEN 8 SYSMEX XN-900 AND ADVIA 2120I ANALYZERS
    Gonzalez Navarro, P.
    Fernandez Jimenez, D.
    Perez Gutierrez, E. M.
    Rivera Gines, A. B.
    Garcia Martin, P.
    Garcia Cabrera, I. M.
    Palacios Rodriguez, J. A.
    Sanchez Moreno, G.
    Rios Tamayo, R.
    Jurado Chacon, M.
    HAEMATOLOGICA, 2018, 103 : 190 - 191
  • [37] NOVEL USE OF THE ADVIA 2120I NUCLEATED RED BLOOD CELL CHANNEL TO PRE-CLASSIFY BLAST LINEAGE
    Gibbs, Graham
    Prechtl, Gottfried
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2018, 40 : 47 - 47
  • [38] EVALUATION OF ANALYTICAL RELIABILITY OF HEMATOLOGY ANALYZER ADVIA 2120: VERIFICATION AND COMPARISON WITH COULTER LH 750
    Velizarova, Milena
    Yacheva, Teodora
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2012, 34 : 136 - 137
  • [39] Performance evaluation of the PENTRA 60C+ automated hematology analyzer and comparison with the ADVIA 2120
    Guerti, K.
    Vertessen, F.
    Daniels, L.
    Van der Planken, M.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2009, 31 (02) : 132 - 141
  • [40] ADVIA 2120i五分类血液分析仪故障维修二例
    李桂明
    中国医疗设备, 2014, 29 (06) : 143 - 144