A comparison of manual counting of rabbit reticulocytes with ADVIA 2120i analyzer counting

被引:2
|
作者
Kaufhold, Annemarie E. [1 ,3 ]
Hirschberger, Johannes [1 ]
Reese, Sven [2 ]
Foerster, Gesine [3 ]
Hein, Jutta [3 ]
机构
[1] Ludwig Maximilians Univ Munchen, Ctr Clin Vet Med, Clin Small Anim Med, Munich, Germany
[2] Ludwig Maximilians Univ Munchen, Ctr Clin Vet Med, Dept Anat Histol & Embryol, Munich, Germany
[3] Synlab Vet Lab, Augsburg, Germany
关键词
EDTA; hematology; Li-heparin; method comparison; rabbits; reticulocyte maturation; HEMATOLOGY ANALYZER; VALUES; CATS; DOGS;
D O I
10.1177/1040638717750428
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
We compared manual counting of reticulocytes in rabbits with automatic counting using an ADVIA 2120i analyzer. Reproducibility and the influence of different anticoagulants (EDTA and Li-heparin) were also examined. Blood samples of 331 rabbits (method comparison, n = 289; reproducibility, n = 33; comparison of anticoagulants, n = 9) were tested. The reticulocyte numbers of each specimen were manually determined twice for method comparison. Passing-Bablok regressions, Bland-Altman plots, and the coefficient of variation (CV) were used to evaluate statistical significance. Good correlation (rs = 0.81) was observed between manual reticulocyte counting (groups 1-4) and the ADVIA 2120i. Quantification with the ADVIA 2120i was reproducible for relative reticulocyte numbers (EDTA, CV = 4.24%; Li-heparin, CV = 3.63%) and absolute reticulocyte numbers (EDTA, CV = 5.64%; Li-heparin, CV = 3.81%). The absolute and relative reticulocyte numbers were significantly higher in Li-heparin samples than in EDTA samples (absolute, p = 0.009; relative, p = 0.016). The ADVIA 2120i is suitable for counting reticulocytes in rabbit blood samples, but reticulocyte numbers are higher by manual counting than by ADVIA 2120i counting. Therefore, microscopic confirmation of quantifications is recommended when high numbers of reticulocytes are observed. The anticoagulant of choice is EDTA.
引用
收藏
页码:337 / 341
页数:5
相关论文
共 50 条
  • [1] COMPARISON OF ATELLICA®HEMA 580 TO ADVIA®2120I
    Chaudhuri, Devyani
    Torabian, Kian
    Patel, Shiven
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2023, 45 : 35 - 35
  • [2] Evaluation and comparison of the new Mindray BC-6200 hematology analyzer with ADVIA 2120i
    Kulik, Katarzyna
    Kwiecien, Iwona
    Chelstowska, Beata
    Rutkowska, Elzbieta
    Rzepecki, Piotr
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2021, 43 (03) : 395 - 402
  • [3] STUDY OF CORRELATION BETWEEN ADVIA 560 AND ADVIA 2120I
    Sale, Silvia
    Fumi, Maurizio
    Pancione, Ylenia
    Rocco, Lucia
    Rocco, Vincenzo
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2016, 38 : 91 - 91
  • [4] BLAST DETECTION ON THE ADVIA 2120I® ANALYSER
    Macias, Laura
    Boldu, Laura
    Molina, Angel
    Bascon, Francisca
    Bedini, J. L.
    Merino, Anna
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2019, 41 : 106 - 107
  • [5] Verification of body fluid mode on haematology analyzer Siemens Advia 2120i
    Vuljanic, D.
    Biljak, V. Radisic
    Simundic, A.
    CLINICA CHIMICA ACTA, 2019, 493 : S413 - S413
  • [6] Verification of hematology analyser Siemens Advia 2120i
    Omazic, J.
    Turalija, T.
    Vrdoljak, I.
    Kostadinovic, J. Wagner
    CLINICA CHIMICA ACTA, 2024, 558
  • [7] Evaluation of the fully automated hematology analyzer Sysmex XN-2000® in a routine laboratory: Comparison with the Advia 2120i®
    Nguyen, V. T. P.
    Vancles, P.
    Rozen, L.
    Noubouossie, D.
    Demulder, A.
    IMMUNO-ANALYSE & BIOLOGIE SPECIALISEE, 2013, 28 (2-3): : 125 - 132
  • [8] Monocytes in Icelandic horses: comparison between automatic gating by the ADVIA 2120i, a manual gating method and microscopic differentiation
    Leidinger E.
    Prechtl G.
    Figl J.
    Leidinger J.
    Comparative Clinical Pathology, 2015, 24 (6) : 1353 - 1359
  • [9] Abnormal ADVIA 2120i neutrophil cytogram in myelodysplastic syndrome
    Gibbs, G.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2017, 39 (03) : E84 - E85
  • [10] Prevalence of myeloperoxidase deficiency determined using an ADVIA 2120i
    Gleghorn, Daniel Mark
    Thomas, Will
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2020, 42 (05) : E220 - E223