Three-dimensional color-coded duplex sonography for assessment of the vertebral artery origin and vertebral artery stenoses

被引:9
|
作者
Harrer, JU
Wessels, T
Poerwowidjojo, S
Möller-Hartmann, W
Klötzsch, C
机构
[1] Aachen Univ Hosp, Dept Neurol, D-52074 Aachen, Germany
[2] Aachen Univ Hosp, Dept Neuroradiol, D-52074 Aachen, Germany
[3] Univ Giessen, Dept Neurol, D-35390 Giessen, Germany
[4] Hegau Klinikum, Kliniken Schmieder Allensbach, Singen, Germany
关键词
angiography; color-coded duplex sonography; Doppler sonography; stenosis; 3-dimensional imaging; vertebral artery;
D O I
10.7863/jum.2004.23.8.1049
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective. The aim of the study was to assess the potential of 3-dimensional (3D) color-coded duplex sonography (CDS) for evaluation of the vertebral artery origin and stenoses in this location. Methods. To compare 2-dimensional (2D) and 3D CDS, both techniques were performed in 25 healthy volunteers and in 18 patients with 21 stenoses of the vertebral artery origin. Stenoses were graded in line with hemodynamic criteria on 2D CDS and according to North American Symptomatic Carotid Endarterectomy Trial criteria on 3D CDS. In 6 patients, digital subtraction angiography (DSA) Was performed additionally. Stenoses were graded according to North American Symptomatic Carotid Endarterectomy Trial criteria and compared with 2D and 3D sonographic data. Results. Overall correlation of both sonographic techniques concerning the grading of the stenoses was good (r = 0.69; P < .01). The interobserver correlation for assessment of stenoses by means of 3D CDS was high (r = 0.94; P < .01). Three-dimensional CDS correlated excellently with DSA in 3 of 6 patients but showed only intermediate or no correlation in the remaining 3 patients. In contrast, spatial information on the stenotic morphologic characteristics was always very comparable with the results obtained by DSA. Conclusions. Three-dimensional CDS represents a valuable tool for assessment of the origin of the vertebral artery, allowing important morphologic information on stenoses in this location. For grading of stenoses of the vertebral artery origin, 3D information should be combined with hemodynamic criteria obtained by spectral Doppler imaging in 2D CDS. Three-dimensional CDS could be a valuable tool before interventional procedures of the proximal vertebral artery, saving time and avoiding iodinated contrast agents.
引用
收藏
页码:1049 / 1056
页数:8
相关论文
共 50 条
  • [31] CERVICAL INTERVERTEBRAL FORAMEN WIDENING CAUSED BY VERTEBRAL ARTERY TORTUOSITY DIAGNOSIS WITH MR AND COLOR-CODED DOPPLER SONOGRAPHY
    SCHIMA, W
    STIGLBAUER, R
    TRATTNIG, S
    HEIMBERGER, K
    KRAMER, J
    IMHOF, H
    BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (782): : 165 - 167
  • [32] Three-dimensional transcranial color-coded sonography of cerebral aneurysms
    Klötzsch, C
    Bozzato, A
    Lammers, G
    Mull, M
    Lennartz, B
    Noth, J
    STROKE, 1999, 30 (11) : 2285 - 2290
  • [33] Transcranial color-coded duplex sonography for detection of distal internal carotid artery stenosis
    Valaikiene, J.
    Schuierer, G.
    Ziennus, B.
    Dietrich, J.
    Bogdahn, U.
    Schlachetzki, F.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (02) : 347 - 353
  • [34] COLOR-CODED DUPLEX SONOGRAPHY OF VERTEBRAL ARTERIES - 11 CASES OF BLUNT CERVICAL-SPINE INJURY
    SIM, E
    SCHWARZ, N
    BIOWSKIFASCHING, I
    BIOWSKI, P
    ACTA ORTHOPAEDICA SCANDINAVICA, 1993, 64 (02): : 133 - 137
  • [35] Visualization of the basilar artery by transcranial color-coded duplex sonography - Comparison with postmortem results
    Schulte-Altedorneburg, G
    Droste, DW
    Popa, V
    Wohlgemuth, WA
    Kellermann, M
    Nabavi, DG
    Csiba, L
    Ringelstein, B
    STROKE, 2000, 31 (05) : 1123 - 1127
  • [36] The hemodynamic effects of internal carotid artery stenting: A study with color-coded duplex sonography
    Lu, CJ
    Kao, HL
    Sun, Y
    Liu, HM
    Jeng, JS
    Yip, PK
    Lee, YT
    CEREBROVASCULAR DISEASES, 2003, 15 (04) : 264 - 269
  • [37] Transcranial color-coded sonography in basilar artery stenting
    Oehm, E
    Els, T
    Spreer, J
    Kassubek, J
    Hetzel, A
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (03): : 383 - 387
  • [38] Assessment of middle cerebral artery diameter after aneurysmal subarachnoid hemorrhage by transcranial color-coded duplex sonography
    Mueller, Martin
    Schwerdtfeger, Karsten
    Zieroth, Siegfried
    European Journal of Ultrasound, 2000, 11 (01) : 15 - 19
  • [39] Transesophageal three-dimensional color Doppler echocardiographic reconstruction of the left vertebral artery
    Ansingkar, KG
    Nanda, NC
    Nekkanti, R
    Aaluri, SR
    Mukhtar, OP
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2001, 18 (07): : 623 - 625
  • [40] THE ASSESSMENT OF DIAGNOSTIC ACCURACY FOR BASILAR ARTERY STENOSIS BY TRANSCRANIAL COLOR-CODED SONOGRAPHY
    Yang, Jie
    Hua, Yang
    Li, Xiang
    Gao, Mingjie
    Li, Qiuping
    Liu, Beibei
    Jiao, Liqun
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2018, 44 (05): : 995 - 1002