Three-dimensional color-coded duplex sonography for assessment of the vertebral artery origin and vertebral artery stenoses

被引:9
|
作者
Harrer, JU
Wessels, T
Poerwowidjojo, S
Möller-Hartmann, W
Klötzsch, C
机构
[1] Aachen Univ Hosp, Dept Neurol, D-52074 Aachen, Germany
[2] Aachen Univ Hosp, Dept Neuroradiol, D-52074 Aachen, Germany
[3] Univ Giessen, Dept Neurol, D-35390 Giessen, Germany
[4] Hegau Klinikum, Kliniken Schmieder Allensbach, Singen, Germany
关键词
angiography; color-coded duplex sonography; Doppler sonography; stenosis; 3-dimensional imaging; vertebral artery;
D O I
10.7863/jum.2004.23.8.1049
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective. The aim of the study was to assess the potential of 3-dimensional (3D) color-coded duplex sonography (CDS) for evaluation of the vertebral artery origin and stenoses in this location. Methods. To compare 2-dimensional (2D) and 3D CDS, both techniques were performed in 25 healthy volunteers and in 18 patients with 21 stenoses of the vertebral artery origin. Stenoses were graded in line with hemodynamic criteria on 2D CDS and according to North American Symptomatic Carotid Endarterectomy Trial criteria on 3D CDS. In 6 patients, digital subtraction angiography (DSA) Was performed additionally. Stenoses were graded according to North American Symptomatic Carotid Endarterectomy Trial criteria and compared with 2D and 3D sonographic data. Results. Overall correlation of both sonographic techniques concerning the grading of the stenoses was good (r = 0.69; P < .01). The interobserver correlation for assessment of stenoses by means of 3D CDS was high (r = 0.94; P < .01). Three-dimensional CDS correlated excellently with DSA in 3 of 6 patients but showed only intermediate or no correlation in the remaining 3 patients. In contrast, spatial information on the stenotic morphologic characteristics was always very comparable with the results obtained by DSA. Conclusions. Three-dimensional CDS represents a valuable tool for assessment of the origin of the vertebral artery, allowing important morphologic information on stenoses in this location. For grading of stenoses of the vertebral artery origin, 3D information should be combined with hemodynamic criteria obtained by spectral Doppler imaging in 2D CDS. Three-dimensional CDS could be a valuable tool before interventional procedures of the proximal vertebral artery, saving time and avoiding iodinated contrast agents.
引用
收藏
页码:1049 / 1056
页数:8
相关论文
共 50 条
  • [21] COLOR-CODED DUPLEX SONOGRAPHY FOR EVALUATION OF RENAL-ARTERY STENOSIS
    SPECKAMP, F
    VORWERK, D
    SCHURMANN, K
    RISSE, JH
    KILBINGER, M
    TACKE, J
    GUNTHER, RW
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1995, 162 (05): : 412 - 419
  • [22] COLOR-CODED DUPLEX SONOGRAPHY IN THE DIAGNOSIS OF RENAL-ARTERY STENOSIS
    KARASCH, T
    STRAUSS, AL
    GRUN, B
    WORRINGER, M
    NEUERBURGHEUSLER, D
    ROTH, FJ
    RIEGER, H
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1993, 118 (40) : 1429 - 1436
  • [23] COLOR-CODED DUPLEX SONOGRAPHY OF RENAL-ARTERY STENOSES - RESULTS OF A PROSPECTIVE-STUDY WITH COMPARISON OF ANGIOGRAPHY
    KRUMME, B
    BLUM, U
    KIRSCHNER, T
    SCHOLLMEYER, P
    KELLER, E
    NIEREN-UND HOCHDRUCKKRANKHEITEN, 1994, 23 (04) : 179 - 181
  • [24] Assessment of ≥50% and &lt;50% intracranial stenoses by transcranial color-coded duplex sonography
    Baumgartner, RW
    Mattle, HP
    Schroth, G
    STROKE, 1999, 30 (01) : 87 - 92
  • [25] Limited sensitivity of transcranial color-coded duplex sonography in the assessment of the posterior communicating artery - Response
    Klotzsch, C
    Popescu, O
    Berlit, P
    STROKE, 1997, 28 (01) : 220 - 220
  • [26] Internal Carotid Artery Hypoplasia Role of Color-Coded Carotid Duplex Sonography
    Chen, Pei-Ya
    Liu, Hung-Yu
    Lim, Kun-Eng
    Lin, Shinn-Kuang
    JOURNAL OF ULTRASOUND IN MEDICINE, 2015, 34 (10) : 1839 - 1851
  • [27] Transcranial color-coded duplex sonography in suspected acute basilar artery occlusion
    Kermer, P
    Wellmer, A
    Crome, O
    Mohr, A
    Knauth, M
    Bähr, M
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2006, 32 (03): : 315 - 320
  • [28] Color-coded duplex sonography for noninvasive diagnosis and grading of renal artery stenosis
    Spies, KP
    Fobbe, F
    ElBedewi, M
    Wolf, KJ
    Distler, A
    Schulte, KL
    AMERICAN JOURNAL OF HYPERTENSION, 1995, 8 (12) : 1222 - 1231
  • [29] Evaluation of Transcranial Color-Coded Duplex Sonography for Cerebral Artery Stenosis or Occlusion
    Hou, Wei Hua
    Liu, Xi
    Duan, Yun You
    Wang, Jia
    Sun, Si Guo
    Deng, Jian Ping
    Qin, Huai Zhou
    Cao, Tie Sheng
    CEREBROVASCULAR DISEASES, 2009, 27 (05) : 479 - 484
  • [30] Intimal carotid artery fibromuscular dysplasia displayed by color-coded duplex sonography
    Winter, R
    Ringleb, P
    Hacke, W
    NERVENARZT, 1998, 69 (10): : 905 - 908