Prosthetic Accuracy Depends on the Design of Patient-Specific Instrumentation: Results of a Retrospective Study Using Three-Dimensional Imaging

被引:2
|
作者
Yamamura, Kazumasa [1 ]
Inori, Fumiaki [1 ]
Konishi, Sadahiko [1 ]
机构
[1] West Japan Railway Co, Osaka Gen Hosp, Dept Orthopaed Surg, Abeno Ku, 1-2-22 Matsuzaki Cho, Osaka 5450053, Japan
关键词
total knee arthroplasty; patient specific instrumentation; three-dimensional evaluation; computed tomography; TOTAL KNEE ARTHROPLASTY; CONVENTIONAL INSTRUMENTATION; MECHANICAL ALIGNMENT; ROTATION; EXPERIENCE; COMPONENT; OUTCOMES; GUIDES; AXIS; TKA;
D O I
10.1055/s-0040-1721127
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
To determine accuracy of patient-specific instrumentation (PSI), the preoperative three-dimensional (3D) plan should be superimposed on the postoperative 3D image to compare prosthetic alignment. We aimed to compare prosthetic alignment on a preoperative 3D computed tomography (CT) plan and postoperative 3D-CT image, and evaluate the accuracy of PSI during total knee arthroplasty (TKA). Thirty consecutive knees (30 patients) who underwent TKA using PSI were retrospectively evaluated. The preoperative plan was prepared using 3D CT acquisitions of the hip, knee, and ankle joints. The postoperative 3D CT image obtained 1 week after surgery was superimposed onto the preoperative 3D plan using computer software. Differences in prosthetic alignment between the preoperative and postoperative images were measured using six parameters: coronal, sagittal, and axial alignments of femoral and tibial prostheses. Differences in prosthetic alignment greater than 3degrees were considered outliers. Two observers performed all measurements. All parameters were repeatedly measured over a 4-week interval. This measurement method's intraobserver and interobserver reliabilities were more than 0.81 (very good). For the femoral and tibial prostheses, absolute differences between the preoperative and postoperative 3D CT images were significantly larger in the sagittal than in the coronal and axial planes ( p <0.001). The outlier rate for the sagittal alignment of femoral and tibial prostheses was significantly higher than that for the alignment of coronal and axial planes ( p <0.001). However, there were no significant differences in the range of motion (ROM) before and after TKA when comparing cases with and without outliers in the sagittal plane. Even though the present study did not reveal any issues with the ROM that depended on the presence of an outlier, accurate verification of prosthetic alignment for individual PSI models may be necessary because the designs, referenced images, and accuracy are different in each model.
引用
收藏
页码:978 / 982
页数:5
相关论文
共 50 条
  • [1] Accuracy of laser-melted patient-specific implants in genioplasty - A three-dimensional retrospective study
    Rueckschloss, Thomas
    Ristow, Oliver
    Kuehle, Reinald
    Weichel, Frederic
    Roser, Christoph
    Aurin, Kerstin
    Engel, Michael
    Hoffmann, Juergen
    Freudlsperger, Christian
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2020, 48 (07) : 653 - 660
  • [2] The Accuracy of Three-Dimensional Planned Bone Tumor Resection Using Patient-Specific Instrument
    Mueller, Daniel A.
    Stutz, Yannik
    Vlachopoulos, Lazaros
    Farshad, Mazda
    Furnstahl, Philipp
    [J]. CANCER MANAGEMENT AND RESEARCH, 2020, 12 : 6533 - 6540
  • [3] Three-Dimensional Planning and Patient-Specific Instrumentation for the Fixation of Distal Radius Fractures
    Pastor, Tatjana
    Nagy, Ladislav
    Furnstahl, Philipp
    Roner, Simon
    Pastor, Torsten
    Schweizer, Andreas
    [J]. MEDICINA-LITHUANIA, 2022, 58 (06):
  • [4] Accuracy of patient-specific implants and additive-manufactured surgical splints in orthognathic surgery - A three-dimensional retrospective study
    Rueckschloss, Thomas
    Ristow, Oliver
    Mueller, Michael
    Kuehle, Reinald
    Zingler, Sebastian
    Engel, Michael
    Hoffmann, Juergen
    Freudlsperger, Christian
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2019, 47 (06) : 847 - 853
  • [5] Accuracy Evaluation of a Three-Dimensional Model Generated from Patient-Specific Monocular Video Data for Maxillofacial Prosthetic Rehabilitation: A Pilot Study
    Matsuo, Moe
    Mine, Yuichi
    Kawahara, Kazuko
    Murayama, Takeshi
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (08): : 712 - 717
  • [6] Three-dimensional planning and use of patient-specific instrumentation (PSI) in total shoulder arthroplasty
    Schmalzl, J.
    Gerhardt, C.
    Lehmann, L. J.
    [J]. ARTHROSKOPIE, 2021, 34 (05) : 358 - 365
  • [7] Three-dimensional planning and use of patient-specific instrumentation (PSI) in total shoulder arthroplasty
    Schmalzl, J.
    Gerhardt, C.
    Lehmann, L. J.
    [J]. OBERE EXTREMITAET-SCHULTER-ELLENBOGEN-HAND-UPPER EXTREMITY-SHOULDER ELBOW HAND, 2020, 15 (03): : 179 - 186
  • [8] Patient-Specific Augmentation Rhinoplasty Using a Three-Dimensional Simulation Program and Three-Dimensional Printing
    Choi, Yim Don
    Kim, Youngjun
    Park, EunSoo
    [J]. AESTHETIC SURGERY JOURNAL, 2017, 37 (09) : 988 - 998
  • [9] Patient-specific airway stent using three-dimensional printing: a review
    Aravena, Carlos
    Gildea, Thomas R.
    [J]. ANNALS OF TRANSLATIONAL MEDICINE, 2022,
  • [10] The Accuracy of a Patient-Specific Three-Dimensional Digital Ostectomy Template for Mandibular Angle Ostectomy
    Wu, Guoping
    Xie, Zhiyang
    Shangguan, Wensong
    Zhang, Wenwen
    Wang, Shu
    Hu, Chao
    Lu, Tong
    Gao, Sheng
    [J]. AESTHETIC SURGERY JOURNAL, 2022, 42 (05) : 447 - 457