Accuracy of patient-specific implants and additive-manufactured surgical splints in orthognathic surgery - A three-dimensional retrospective study

被引:37
|
作者
Rueckschloss, Thomas [1 ]
Ristow, Oliver [1 ]
Mueller, Michael [1 ]
Kuehle, Reinald [1 ]
Zingler, Sebastian [2 ]
Engel, Michael [1 ]
Hoffmann, Juergen [1 ]
Freudlsperger, Christian [1 ]
机构
[1] Heidelberg Univ, Dept Oral & Maxillofacial Surg, Neuenheimer Feld 400, D-69120 Heidelberg, Germany
[2] Heidelberg Univ, Dept Orthodont, Neuenheimer Feld 400, D-69120 Heidelberg, Germany
关键词
Orthognathic surgery; Virtual planning; Patient-specific implant; Class III; FACE-BOW TRANSFER; MODEL SURGERY; GUIDED NAVIGATION; SIMULATION; LANDMARKS; REPRODUCIBILITY; OSTEOSYNTHESIS; PREDICTION; PROTOCOL;
D O I
10.1016/j.jcms.2019.02.011
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: Because of the many limitations of conventional surgery planning for the treatment of orthognathic deformities, as well as advancements in computer-assisted planning, there is an urgent need for technical devices that transfer the surgical plan into the operating theatre. In this regard, additive-manufactured, patient-specific implants (PSI) and additive-manufactured interocclusal splints represent promising approaches. The aim of this retrospective study was to compare the accuracy of these two devices, with regard to preoperative virtual treatment planning for maxillary Le-Fort I advancement surgery using IPS CaseDesigner (R), and based on a new analysis method without the use of landmarks. Materials and methods: A retrospective evaluation of 18 class III patients (n(PSI) = 9; n(splint) = 9), who had undergone virtually planned orthognathic surgery (including maxillary Le Fort I advancement), was performed. The preoperative treatment plan and the postoperative outcome were combined to calculate the translational and rotational discrepancies between the 3D planning and the actual surgical outcome. Results: For the PSI and splint groups the accuracy of left/right positioning was 0.51 mm +/- 0.48 and 1.11 mm +/- 1.32 respectively. The accuracy of anterior/posterior positioning was 0.39 mm +/- 0.26 and 1.42 mm +/- 0.87, and that of up/down-positioning was 0.44 mm +/- 0.31 and 0.62 mm +/- 0.47. The rotational discrepancies were less than 2 degrees in both groups. Conclusion: The findings demonstrate that both PSI and splint approaches can accurately transfer the virtual planning into the operating theatre. However, PSIs show an overall higher accuracy, especially for anterior/posterior translational movement (p < 0.002). (c) 2019 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:847 / 853
页数:7
相关论文
共 50 条
  • [1] Accuracy of maxillary positioning using computer-designed and manufactured occlusal splints or patient-specific implants in orthognathic surgery
    Malenova, Yoana
    Ortner, Florian
    Liokatis, Paris
    Haidari, Selgai
    Troeltzsch, Matthias
    Fegg, Florian
    Obermeier, Katharina T.
    Hartung, Jens T.
    Kakoschke, Tamara K.
    Burian, Egon
    Otto, Sven
    Sabbagh, Hisham
    Probst, Florian A.
    [J]. CLINICAL ORAL INVESTIGATIONS, 2023, 27 (09) : 5063 - 5072
  • [2] Accuracy of maxillary positioning using computer-designed and manufactured occlusal splints or patient-specific implants in orthognathic surgery
    Yoana Malenova
    Florian Ortner
    Paris Liokatis
    Selgai Haidari
    Matthias Tröltzsch
    Florian Fegg
    Katharina T. Obermeier
    Jens T. Hartung
    Tamara K. Kakoschke
    Egon Burian
    Sven Otto
    Hisham Sabbagh
    Florian A. Probst
    [J]. Clinical Oral Investigations, 2023, 27 : 5063 - 5072
  • [3] Finite element analysis of patient-specific additive-manufactured implants
    Namvar, Arman
    Lozanovski, Bill
    Downing, David
    Williamson, Tom
    Kastrati, Endri
    Shidid, Darpan
    Hill, David
    Buehner, Ulrich
    Ryan, Stewart
    Choong, Peter F.
    Sanaei, Reza
    Leary, Martin
    Brandt, Milan
    [J]. FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [4] Accuracy of laser-melted patient-specific implants in genioplasty - A three-dimensional retrospective study
    Rueckschloss, Thomas
    Ristow, Oliver
    Kuehle, Reinald
    Weichel, Frederic
    Roser, Christoph
    Aurin, Kerstin
    Engel, Michael
    Hoffmann, Juergen
    Freudlsperger, Christian
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2020, 48 (07) : 653 - 660
  • [5] Randomized Clinical Trial of the Accuracy of Patient-Specific Implants versus CAD/CAM Splints in Orthognathic Surgery
    Li, Biao
    Wei, Hongpu
    Jiang, Tengfei
    Qian, Yifeng
    Zhang, Tianjia
    Yu, Hongbo
    Zhang, Lei
    Wang, Xudong
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 2021, 148 (05): : 1101 - 1110
  • [6] Patient-Specific Implants in Orthognathic Surgery
    Li, Dion Tik Shun
    Leung, Yiu Yan
    [J]. ORAL AND MAXILLOFACIAL SURGERY CLINICS OF NORTH AMERICA, 2023, 35 (01) : 61 - 69
  • [7] Properties of Additive-Manufactured Open Porous Titanium Structures for Patient-Specific Load-Bearing Implants
    Zumofen, Livia
    Kopanska, Katarzyna S.
    Bono, Epifania
    Kirchheim, Andreas
    De Haller, Emmanuel B.
    Graf-Hausner, Ursula
    [J]. FRONTIERS IN MECHANICAL ENGINEERING-SWITZERLAND, 2022, 7
  • [8] Manufacturing splints for orthognathic surgery using a three-dimensional printer
    Metzger, Marc Christian
    Hohlweg-Majert, Bettina
    Schwarz, Uli
    Teschner, Matthias
    Hammer, Beat
    Schmelzeisen, Rainer
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2008, 105 (02): : E1 - E7
  • [9] Three-Dimensional Repositioning of the Maxilla in Orthognathic Surgery Using Patient-Specific Titanium Plates: A Case Series
    Greenberg, Seth
    Buchbinder, Daniel
    Turner, Michael D.
    Dhillon, Prince
    Afshar, Alex Ali
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2021, 79 (04) : 902 - 913
  • [10] Prosthetic Accuracy Depends on the Design of Patient-Specific Instrumentation: Results of a Retrospective Study Using Three-Dimensional Imaging
    Yamamura, Kazumasa
    Inori, Fumiaki
    Konishi, Sadahiko
    [J]. JOURNAL OF KNEE SURGERY, 2022, 35 (09) : 978 - 982