Three-Dimensional Planning and Patient-Specific Instrumentation for the Fixation of Distal Radius Fractures

被引:12
|
作者
Pastor, Tatjana [1 ,2 ]
Nagy, Ladislav [1 ]
Furnstahl, Philipp [3 ]
Roner, Simon [1 ]
Pastor, Torsten [1 ]
Schweizer, Andreas [1 ]
机构
[1] Univ Zurich, Balgrist Univ Hosp, Dept Hand Surg, CH-8008 Zurich, Switzerland
[2] Univ Bern, Univ Hosp Bern, Inselspital, Dept Plast & Hand Surg, CH-3007 Bern, Switzerland
[3] Univ Zurich, Balgrist Univ Hosp, Comp Assisted Res & Dev Team, CH-8008 Zurich, Switzerland
来源
MEDICINA-LITHUANIA | 2022年 / 58卷 / 06期
关键词
distal radius fracture; 3D planning; patient-specific guide; preoperative planning; osteosynthesis; DISPLACED INTRAARTICULAR FRACTURES; CORRECTIVE OSTEOTOMY; OPEN REDUCTION; MALUNITED FRACTURES; OPERATIVE TREATMENT; INTERNAL-FIXATION; PLATE FIXATION; FOREARM; END; WRIST;
D O I
10.3390/medicina58060744
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Objectives: Three-dimensional planning and guided osteotomy utilizing patient-specific instrumentation (PSI) with the contralateral side used as a reference have been proven as effective in the treatment of malunions following complex fractures of the distal radius. However, this approach has not yet been described in relation to fracture reduction of the distal radius. The aim of this study was to assess the technical and logistical feasibility of computer-assisted surgery in a clinical setting using PSI for fracture reduction and fixation. Materials and Methods: Five patients with varied fracture patterns of the distal radius underwent operative treatment with using PSI. The first applied PSI guide allowed specific and accurate placement of Kirschner wires inside the multiple fragments, with subsequent concurrent reduction using a second guide. Results: Planning, printing of the guides, and operations were performed within 5.6 days on average (range of 1-10 days). All patients could be treated within a reasonable period of time, demonstrating good outcomes, and were able to return to work after a follow-up of three months. Mean wrist movements (degrees) were 58 (standard deviation (SD) 21) in flexion, 62 (SD 15) in extension, 73 (SD 4) in pronation and 74 (SD 10) in supination at a minimum follow-up of 6 months. Conclusions: Three-dimensional planned osteosynthesis using PSI for treatment of distal radius fractures is feasible and facilitates reduction of multiple fracture fragments. However, higher costs must be taken into consideration for this treatment.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Three-dimensional planning and use of patient-specific instrumentation (PSI) in total shoulder arthroplasty
    Schmalzl, J.
    Gerhardt, C.
    Lehmann, L. J.
    [J]. ARTHROSKOPIE, 2021, 34 (05) : 358 - 365
  • [2] Three-dimensional planning and use of patient-specific instrumentation (PSI) in total shoulder arthroplasty
    Schmalzl, J.
    Gerhardt, C.
    Lehmann, L. J.
    [J]. OBERE EXTREMITAET-SCHULTER-ELLENBOGEN-HAND-UPPER EXTREMITY-SHOULDER ELBOW HAND, 2020, 15 (03): : 179 - 186
  • [3] Three-dimensional evaluations of preoperative planning reproducibility for the osteosynthesis of distal radius fractures
    Yuichi Yoshii
    Takeshi Ogawa
    Atsuo Shigi
    Kunihiro Oka
    Tsuyoshi Murase
    Tomoo Ishii
    [J]. Journal of Orthopaedic Surgery and Research, 16
  • [4] Three-dimensional evaluations of preoperative planning reproducibility for the osteosynthesis of distal radius fractures
    Yoshii, Yuichi
    Ogawa, Takeshi
    Shigi, Atsuo
    Oka, Kunihiro
    Murase, Tsuyoshi
    Ishii, Tomoo
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [5] Three-Dimensional Correction of Distal Radius Intra-Articular Malunions Using Patient-Specific Drill Guides
    Schweizer, Andreas
    Fuernstahl, Philipp
    Nagy, Ladislav
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2013, 38A (12): : 2339 - 2347
  • [6] Patient-specific plate for navigation and fixation of the distal radius: a case series
    Dobbe, Johannes G. G.
    Peymani, Abbas
    Roos, Hendrika A. L.
    Beerens, Maikel
    Streekstra, Geert J.
    Strackee, Simon D.
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2021, 16 (03) : 515 - 524
  • [7] Biomechanical considerations in the design of patient-specific fixation plates for the distal radius
    G. Caiti
    J. G. G. Dobbe
    E. Bervoets
    M. Beerens
    S. D. Strackee
    G. J. Strijkers
    G. J. Streekstra
    [J]. Medical & Biological Engineering & Computing, 2019, 57 : 1099 - 1107
  • [8] Biomechanical considerations in the design of patient-specific fixation plates for the distal radius
    Caiti, G.
    Dobbe, J. G. G.
    Bervoets, E.
    Beerens, M.
    Strackee, S. D.
    Strijkers, J.
    Streekstra, G. J.
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2019, 57 (05) : 1099 - 1107
  • [9] Patient-specific plate for navigation and fixation of the distal radius: a case series
    Johannes G. G. Dobbe
    Abbas Peymani
    Hendrika A. L. Roos
    Maikel Beerens
    Geert J. Streekstra
    Simon D. Strackee
    [J]. International Journal of Computer Assisted Radiology and Surgery, 2021, 16 : 515 - 524
  • [10] Three-dimensional planning, navigation, patient-specific instrumentation and mixed reality in shoulder arthroplasty: a digital orthopedic renaissance
    Kolac, Ulas Can
    Paksoy, Alp
    Akguen, Doruk
    [J]. EFORT OPEN REVIEWS, 2024, 9 (06) : 527 - 527