C2 partial transpedicular screw technique for atlantoaxial dislocation with high-riding vertebral artery: A technique note with case series

被引:8
|
作者
Guo, Qunfeng [1 ]
Zhou, Xin [1 ]
Guo, Xiang [1 ]
Han, Zhao [1 ]
Chen, Fei [1 ]
Zhu, Jingyu [1 ]
Lu, Xuhua [1 ]
Ni, Bin [1 ]
机构
[1] Second Mil Med Univ, Changzheng Hosp, Dept Orthoped, 415 Fengyang Rd, Shanghai 200003, Peoples R China
基金
中国国家自然科学基金;
关键词
Atlantoaxial dislocation; Atlantoaxial arthrodesis; Atlantoaxial fusion; C2 pedicle screw; C2 partial transpedicular screw; PEDICLE SCREWS; C1-C2; FUSION; FIXATION; PLACEMENT; STABILITY; FORAMEN; GROOVE; PLATE;
D O I
10.1016/j.clineuro.2020.106403
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: Although the C2 pedicle screw (C2PS) is currently the most biomechanically robust option for C2 fixation, the high-riding vertebral artery (HRVA) precludes safe C2PS placement. However, unintentional partial C2 pedicle perforation and vertebral foramen violation due to C2PS placement without neurovascular complications occurred frequently in clinic. Therefore, we have attempted to apply C2 partial transpedicular screw (C2PTS) in patients with HRVA with satisfactory preliminary outcomes. The aim of the present study is to introduce the C2PTS technique and report the preliminary radiological and clinical outcomes of application of C2PTS. Patients and methods: The data of 15 patients with atlantoaxial dislocation underwent atlantoaxial arthrodesis with posterior screw-rod construct were retrospectively reviewed. All patients had unilateral or bilateral HRVA that precluded safe C2PS placement and C2PTS was used as an alternative. In this technique, a Penfield dissector was used to properly mobilize the HRVA inferiorly to preclude vertebral artery injury and pave the way for C2PTS placement. The C2PTS travelled under the superior border of the isthmus and toward the ipsilateral atlantoaxial articulation. The implant position and atlantoaxial reduction were evaluated using computed tomography (CT) scans and vertebral artery (VA) was assessed using CT angiography postoperatively. Results: Satisfactory C2PTS placement and atlantoaxial reduction were achieved in all patients. Postoperatively, no vertebral artery injury and implant failure were observed, and bone fusion was achieved in all the patients. Additionally, there were no VA occlusion or stenosis due to screws demonstrated on VA CT angiography. Conclusion: C2PTS can achieve three-column fixation of axis and is an efficient alternative to C2PS which is prohibited due to HRVA; also, gently mobilizing the HRVA inferiorly is mandatory to prevent vertebral artery injury during C2PTS placement.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Modification of Wright’s technique for C2 translaminar screw fixation: technical note
    S. M. R. Kabir
    A. T. H. Casey
    Acta Neurochirurgica, 2009, 151 : 1543 - 1547
  • [42] Risk of the high-riding variant of vertebral arteries at C2 is increased over twofold in rheumatoid arthritis: a meta-analysis
    Tomasz Klepinowski
    Jagoda Cembik
    Leszek Sagan
    Neurosurgical Review, 2021, 44 : 2041 - 2046
  • [43] Risk of the high-riding variant of vertebral arteries at C2 is increased over twofold in rheumatoid arthritis: a meta-analysis
    Klepinowski, Tomasz
    Cembik, Jagoda
    Sagan, Leszek
    NEUROSURGICAL REVIEW, 2021, 44 (04) : 2041 - 2046
  • [44] C2 laminar screw and C1-2 transarticular screw combined with C1 laminar hooks for atlantoaxial instability with unilateral vertebral artery injury
    Qunfeng Guo
    Jun Liu
    Bin Ni
    Xuhua Lu
    Fengjin Zhou
    Archives of Orthopaedic and Trauma Surgery, 2011, 131 : 1207 - 1210
  • [45] C2 laminar screw and C1-2 transarticular screw combined with C1 laminar hooks for atlantoaxial instability with unilateral vertebral artery injury
    Guo, Qunfeng
    Liu, Jun
    Ni, Bin
    Lu, Xuhua
    Zhou, Fengjin
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (09) : 1207 - 1210
  • [46] Posterior realignment of irreducible atlantoaxial dislocation with C1-C2 screw and rod system: a technique of direct reduction and fixation
    Yin, Yi-Heng
    Qiao, Guang-Yu
    Yu, Xin-Guang
    Tong, Huai-Yu
    Zhang, Yuan-Zheng
    SPINE JOURNAL, 2013, 13 (12): : 1864 - 1871
  • [47] The C2 Pedicle Width, Pars Length, and Laminar Thickness in Concurrent Ipsilateral Ponticulus Posticus and High-Riding Vertebral Artery: A Radiological Computed Tomography Scan-Based Study
    Kothari, Manish Kundanmal
    Dalvie, Samir Surendranath
    Gupta, Santosh
    Tikoo, Agnivesh
    Singh, Deepak Kumar
    ASIAN SPINE JOURNAL, 2019, 13 (02) : 290 - 295
  • [48] A screw algorithm for congenital C2-3 fusion with high-riding vertebral arteries: feasibilities and clinical outcomes of five different fixation techniques
    Jian, Qiang
    Hou, Zhe
    Zhao, Xingang
    Wang, Yinqian
    Liang, Cong
    Fan, Tao
    NEUROSURGICAL REVIEW, 2024, 47 (01)
  • [49] Prevalence of high-riding vertebral arteries and narrow C2 pedicles among Central-European population: a computed tomography-based study
    Klepinowski, Tomasz
    Zylka, Natalia
    Pala, Bartlomiej
    Poncyljusz, Wojciech
    Sagan, Leszek
    NEUROSURGICAL REVIEW, 2021, 44 (06) : 3277 - 3282
  • [50] Prevalence of high-riding vertebral arteries and narrow C2 pedicles among Central-European population: a computed tomography-based study
    Tomasz Klepinowski
    Natalia Żyłka
    Bartłomiej Pala
    Wojciech Poncyljusz
    Leszek Sagan
    Neurosurgical Review, 2021, 44 : 3277 - 3282